Electrical distributor of high quality products to the LA and Orange County markets

Call Us Today To get a Quote
ATS480M10Y – soft starter, Altistart 480, 1000A, 208…690V AC, control supply 110…230V AC
ATS480M10Y
Soft starter, Altistart 480, 1000A, 208 to 690V AC, control supply 110 to 230V AC

Altivar Soft Starter ATS480 is intended to start and stop asynchronous motors supplied from 208V to 690V. It meets the requirements of the most demanding applications in normal and heavy duty. With an operational rated current of 1000A in normal duty, it supplies motor from 250kW to 900kW according to mains voltage. Designed for digitization, connected, optimized to meet cybersecurity standard, it simplifies project execution and maximizes the availability of applications. Its torque control (TCS) masters acceleration and deceleration. It efficiently stops high inertia application thanks to the dynamic braking and DC injection. It could be connected in-line or inside the delta to reduce its operational current. The embedded test routine simplifies the commissioning inside the delta. Its dimensions are 770mm (width) x 329mm (depth) x 890mm (height) and it weighs 115kg. Altivar Soft Starter ATS480 is designed to address process, infrastructures and industrial machines. It conforms to IEC/EN60947-4-1. It is certified CE, cULus, UKCA, CCC, RCM, EAC, and Marine certified DNV, ABS, BV and CCS. Display terminals, remote mounting kit, communication modules are common with Altivar Drives. Line chokes, DNV kits are common with ATS48. ATS480 is compatible with ATS48, it has same footprint, fixing, torque control algorithm, I/O, menus… The integration of Altivar Soft Starter ATS480 in EcoStruxure drastically simplifies architecture selection, detailed design and execution in automation and electrical systems. It is a Green Premium product designed to take the environmental considerations beyond current directives and regulations, compliant with RoHS and REACH.

Brand: Schneider Electric

Add to Quote Catalogue
Specifications
Product Destination asynchronous motors
Range Of Product Altivar Soft Starter ATS480
Product Or Component Type soft starter
Maximum Permanent Current 790.0 A at 40 °C heavy duty
Motor Power Kw
  • 250.0 kW 230 V in the motor supply line normal duty
  • 220.0 kW 230 V in the motor supply line heavy duty
  • 500.0 kW 400 V in the motor supply line normal duty
  • 400.0 kW 400 V in the motor supply line heavy duty
  • 630.0 kW 440 V in the motor supply line normal duty
  • 500.0 kW 440 V in the motor supply line heavy duty
  • 630.0 kW 500 V in the motor supply line normal duty
  • 500.0 kW 500 V in the motor supply line heavy duty
  • 630.0 kW 525 V in the motor supply line normal duty
  • 500.0 kW 525 V in the motor supply line heavy duty
  • 900.0 kW 660 V in the motor supply line normal duty
  • 710.0 kW 660 V in the motor supply line heavy duty
  • 900.0 kW 690 V in the motor supply line normal duty
  • 710.0 kW 690 V in the motor supply line heavy duty
  • 355.0 kW 230 V to the motor delta terminals heavy duty
  • 710.0 kW 400 V to the motor delta terminals normal duty
  • 630.0 kW 400 V to the motor delta terminals heavy duty
Phase 3 phase
Utilisation Category
  • AC-3A
  • AC-53A
[Ie] Rated Operational Current normal duty 1000.0 A 40 °C)
[Us] Rated Supply Voltage 208...690 V - 15...10 %
Product Specific Application process and infrastructures
Torque Control true
Maximum Horse Power Rating
  • 350.0 hp 208 V normal duty
  • 250.0 hp 208 V heavy duty
  • 350.0 hp 230 V normal duty
  • 300.0 hp 230 V heavy duty
  • 800.0 hp 460 V normal duty
  • 600.0 hp 460 V heavy duty
  • 1000.0 hp 575 V normal duty
  • 800.0 hp 575 V heavy duty
Device Short Name ATS480
Ip Degree Of Protection IP00
Supply Frequency 50...60 Hz - 20...20 %
Option Card
  • communication module Profibus DP V1
  • communication module PROFINET
  • communication module Modbus TCP/EtherNet/IP
  • communication module CANopen daisy chain
  • communication module CANopen Sub-D
  • communication module CANopen open style
Product Certifications
  • CE
  • cULus
  • CCC
  • UKCA
  • RCM
  • EAC
  • DNV
  • ABS
  • BV
  • CCS
Device Connection
  • in the motor supply line
  • to the motor delta terminals
Height 890.0 mm
Standards
  • EN/IEC 60947-4-2
  • UL 60947-4-2
  • IEC 60664-1
Transmission Frame RTU
Analogue Output Type current output AQ1 0...20 mA or 0...10 V 500 Ohm
[Uc] Control Circuit Voltage 110...230 V AC 50/60 Hz - 15...10 %
Maximum Switching Current
  • relay outputs 2 A 250 V AC
  • relay outputs 2 A 30 V DC
  • relay outputs
Relay Output Number 3
Data Format 8 bits, configurable odd, even or no parity
Marking
  • CE
  • CCC
  • UKCA
  • EAC
  • RCM
  • cULus
Output Current Drift 150-700 %
Display Screen Available true
Net Weight 115.0 kg
Relay Output Type
  • relay outputs R1A 1 NO
  • relay outputs R1B 1 NO
  • relay outputs RIC NO/NC programmable
Connector Type 1 RJ45
Analogue Input Number 1
Communication Data Link serial
Function Available
  • external bypass control
  • pre-heating
  • smoke extraction
  • multi-motor cascade
  • second motor set
  • user management
  • ports and services hardening
  • security event logging
  • cybersecure firmware update
  • single direction
Discrete Output Number 2
Communication Port Protocol Modbus serial
Discrete Input Type
  • STOP) logic inputs, 3500 Ohm
  • RUN) logic inputs, 3500 Ohm
  • DI3) programmable as logic input, 3500 Ohm
  • DI4) programmable as logic input, 3500 Ohm
Minimum Switching Current 10 mA 24 V DC relay outputs
Analogue Output Number 1
Physical Interface 2-wire RS 485
Method Of Access slave Modbus serial
Integrated Motor Overload Protection true
[In] Rated Current Pwr Loss Specifctn 1000.0 A
Discrete Input Number 4
Accuracy Class class 10E
Power Loss Per Device Current Dependent 2845.0 W
Number Of Addresses 0-227 Modbus serial
Apparent Power 0.2 kVA
Operating Position vertical +/- 10 degree
Power Loss Static Current Independent 25.0 W
Type Of Polarization no impedance Modbus serial
Width 770.0 mm
Transmission Rate 1200...256000 bit/s
Depth 329.0 mm
Discrete Input Logic programmable digital input < 5 V
Protection Type
  • phase failure line
  • integrated thermal protection motor
  • thermal protection starter
  • current overload motor
  • underload motor
  • excessive starting time, locked rotor motor
  • motor phase loss motor
  • line supply phase loss line
  • line supply phase loss motor
  • thermal protection motor
Discrete Output Type
  • DQ1) programmable digital output <= 30 V
  • DQ2) programmable digital output <= 30 V
Rohs Exemption Information Yes
Mercury Free Yes
Environmental Disclosure ENVPEP2102014EN
Sustainable Offer Status Green Premium product
Reach Regulation Reference contains Substances of Very High Concern above the threshold
California Proposition 65 WARNING: This product can expose you to chemicals including: Lead and lead compounds, which is known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov
Weee The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
China Rohs Regulation X
Circularity Profile ENVEOLI2102014EN
Upgradeability Upgraded components available
Eu Rohs Directive Pro-active compliance (Product out of EU RoHS legal scope)
Maximum Acceleration Under Vibratory Load (During Transport)
  • 15 m/s² at 200...500 Hz
  • 10 m/s² at 9...200 Hz
Maximum Acceleration Under Shock Load (During Transport) 100 m/s² at 11 ms
Maximum Deflection Under Vibratory Load (During Operation) 1.5 mm at 2...13 Hz
Maximum Acceleration Under Shock Impact (During Operation) 150 m/s² at 11 ms
[Uimp] Rated Impulse Withstand Voltage 6 kV
Pollution Degree level 3
Electromagnetic Compatibility
  • conducted and radiated emissions level A IEC 60947-4-2
  • conducted and radiated emissions with bypass level B IEC 60947-4-2
  • damped oscillating waves level 3 IEC 61000-4-12
  • electrostatic discharge level 3 IEC 61000-4-11
  • immunity to electrical transients level 4 IEC 61000-4-4
  • immunity to radiated radio-electrical interference level 3 IEC 61000-4-3
  • voltage/current impulse level 3 IEC 61000-4-5
Ambient Air Temperature For Operation
  • 40-60 °C with current derating of 2 % per °C)
  • -15-40 °C without derating)
Maximum Deflection Under Vibratory Load (During Transport) 1.75 mm at 2...9 Hz
[Ui] Rated Insulation Voltage 690 V
Maximum Acceleration Under Vibrational Stress (During Operation) 10 m/s² at 13...200 Hz
Maximum Acceleration Under Vibratory Load (During Storage)
  • 15 m/s² at 200...500 Hz
  • 10 m/s² at 9...200 Hz
Ambient Air Temperature For Storage -25-70 °C
Relative Humidity 0-95 % without condensation or dripping water EN/IEC 60068-2-3
Operating Altitude
  • <= 3280.84 ft (1000 m) without derating
  • > 3280.84...13123.36 ft (> 1000...4000 m) with current derating 1 % per 100 m
Maximum Acceleration Under Shock Load (During Storage) 100 m/s² at 11 ms
Environmental Class (During Operation)
  • class 3C3 according to IEC 60721-3-3
  • class 3S2 according to IEC 60721-3-3
Maximum Deflection Under Vibratory Load (During Storage) 1.75 mm at 2...9 Hz
Documents
Royal Wholesale Electric

5.0

Powered by

Based on 2 User Reviews