Electrical distributor of high quality products to the LA and Orange County markets

Call Us Today To get a Quote
ABLS1A12062 – Regulated Power Supply, 100…240V AC, 12V, 6.2A, single phase, Optimized
ABLS1A12062
Regulated Power Supply, 100...240V AC, 12V, 6.2A, single phase, Optimized

This ABLS regulated switch mode power supply (SMPS) supplies direct current voltage. It has a rated input of 100V to 240V AC and 140 V to 340 V DC, a rated output current of 6,25A at 12V DC and a rated power output of 75W. It is ideal for supplying DC voltage necessary for automation equipment designed for applications in industrial, commercial and residential applications such as conveying, packaging, control, food & beverage, mining, oil & gas and water. It installs on omega rail or fixing by screw. Its width is 27mm, its height is 123,6mm, its depth is 102mm. It ensures a protection against overloads and short-circuits with automatic restart after the source of overload/short-circuit has been corrected. It weighs 0.220kg. It is a power supply for industrial use, rail mounting. It conforms to EN62368-1, ENIEC61010-1/2-201, ENIEC61204-3, EN61000-6-1/2/3/4, EN61000-3-2-3, UL62368-1, UL61010-2-201/-1-201, CSAC22.2No62368-1/No61010-2-201/No61010-1 standards, and certified by CE, CUL listed/recognized, RCM, CBscheme. The Acti9 iC60 range of Miniature Circuit Breakers is recommanded for its protection. The type of protection is 10A, C curve or 13A, B-curve. It has in the front face a LED indicating presence of DC output voltage, and a QR code for access to the latest technical documentation. Thanks to its book housing, it can be installed either in enclosures or industrial panels by clipping on omega (DIN) rail. It brings energy to your automated systems. Designed for simple machines and applications, modular power supplies are primarily appreciated for their extreme compactness.

Brand: Schneider Electric

Add to Quote Catalogue
Specifications
Range Of Product Modicon Power Supply
Output Voltage 12 V DC
Product Or Component Type power supply
Power Supply Type regulated switch mode
Input Voltage
  • 100...240 V AC single phase
  • 100...240 V AC phase to phase
  • 140...340 V DC
Power Supply Output Current 6.25 A
Kw Rating 75 W
Enclosure Material Plastic
Output Coupling
  • parallel
  • serial
Height 123.6 mm
Residual Ripple < 120 mV
Status Led 1 LED (Green) output voltage
Holding Time
  • > 20 ms 115 V AC
  • > 40 ms 230 V AC
Efficiency At Full Load
  • 85...264 V AC without temperature derating
  • 120...375 V DC without temperature derating
  • 85…120 V DC with temperature derating
Earthing System
  • TN
  • TT
  • IT
Connections - Terminals
  • screw connection 0.5...2.5 mm², AWG 20...AWG 14) output
  • screw connection 0.75...2.5 mm², AWG 18...AWG 14) input
Dielectric Strength 3000 V AC with input to output
Network Frequency Limits 50-60 Hz
Current Consumption
  • < 1.8 A 115 V AC
  • < 1 A 230 V AC
  • < 0.8 A 140 V DC
Supply
  • SELV EN/IEC 60950-1
  • SELV EN/IEC 60204-1
  • SELV IEC 60364-4-41
Net Weight 0.22 kg
Maximum Leakage Current 1 mA 240 V AC
Input Protection Type
  • integrated fuse (not interchangeable) 5 A
  • external protection (recommended) 20 A Curve C
  • external protection (recommended) 13 A Curve B
  • external protection (recommended) 10 A Curve C
Output Protection Type
  • against overload and short-circuits automatic reset
  • against over temperature manual reset
  • against overvoltage manual reset
Service Life 10 year(s)
Meantime Between Failure [Mtbf] 700000 h at 25 °C, full load conforming to SR 332
Power Dissipation In W 16 W
Output Voltage Limits 11...14 V
Mounting Support
  • top hat type TH35-15 rail IEC 60715
  • top hat type TH35-7.5 rail IEC 60715
  • double-profile DIN rail
Load Capacitance 5000 µF
Response Time < 1.2 s
Line And Load Regulation
  • < 0.5 % network 0 to 100 % load at 25 °C
  • < 1 % network full voltage range in line at 25 °C
Width 27 mm
Overvoltage Category II
Inrush Current
  • 40.0 A 115 V
  • 80.0 A 230 V
Efficiency 87 % 230 V AC
Depth 102 mm
Power Factor
  • 0.55 at 115 V AC
  • 0.45 at 230 V AC
Rohs Exemption Information Yes
Mercury Free Yes
Environmental Disclosure ENVPEP2007005EN
Sustainable Offer Status Green Premium product
Reach Regulation Reference contains Substances of Very High Concern above the threshold
California Proposition 65 WARNING: This product can expose you to chemicals including: Lead and lead compounds, which is known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov
Weee The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
China Rohs Regulation X
Circularity Profile ENVEOLI2007005EN
Eu Rohs Directive Pro-active compliance (Product out of EU RoHS legal scope)
Standards
  • EN 62368-1
  • EN/IEC 61010-1
  • EN 61010-2-201
  • EN/IEC 61204-3
  • EN 61000-6-1
  • EN 61000-6-2
  • EN 61000-6-3
  • EN 61000-6-4
  • EN 61000-3-2
  • EN 61000-3-3
  • UL 62368-1
  • UL 61010-1
  • UL 61010-2-201
  • CSA C22.2 No 62368-1
  • CSA C22.2 No 61010-1
  • CSA C22.2 No 61010-2-201
  • EN/IEC 62368-1
Ambient Air Temperature For Operation
  • -20--10 °C with current derating of 1 % per °C mounting position A < 6561.68 ft (2000 m)
  • -10-40 °C without derating mounting position A 115 V AC < 6561.68 ft (2000 m)
  • -10-50 °C without derating mounting position A 230 V AC < 6561.68 ft (2000 m)
  • 40-70 °C with current derating of 1.67 % per °C mounting position A 115 V AC < 6561.68 ft (2000 m)
  • 50-70 °C with current derating of 2.5 % per °C mounting position A 230 V AC < 6561.68 ft (2000 m)
Product Certifications
  • CE
  • cUL Listed
  • cUL Recognized
  • RCM
  • CB Scheme
  • EAC
  • KC
  • NEC class 2
Pollution Degree 2
Electromagnetic Compatibility
  • immunity to electrostatic discharge 8 kV contact discharge) EN/IEC 61000-4-2
  • immunity to electrostatic discharge 15 kV air discharge) EN/IEC 61000-4-2
  • immunity to conducted RF disturbances 15 V/m 80 MHz...2 GHz) EN/IEC 61000-4-3
  • immunity to conducted RF disturbances 5 V/m 2...2.7 GHz) EN/IEC 61000-4-3
  • immunity to conducted RF disturbances 5 V/m 2.7...6 GHz) EN/IEC 61000-4-3
  • immunity to fast transients 4 kV on input-output) EN/IEC 61000-4-4
  • surge immunity test 4 kV between power supply and earth) EN/IEC 61000-4-5
  • surge immunity test 3 kV between phases) EN/IEC 61000-4-5
  • immunity to conducted RF disturbances 15 V 0.15...80 MHz) EN/IEC 61000-4-6
  • immunity to magnetic fields 30 A/m 50...60 Hz) EN/IEC 61000-4-8
  • immunity to voltage dips EN/IEC 61000-4-11
  • disturbing field emission EN 55016-2-3
  • limits for harmonic current emissions EN 61000-3-2
  • EN 55016-1-2
  • EN 55016-2-1
Shock Resistance 150 m/s² 11 ms
Vibration Resistance
  • 3 mm 2-9 Hz)IEC 60068-2-6
  • 10 m/s² 9-200 Hz)IEC 60068-2-6
Ip Degree Of Protection IP20
Operating Altitude < 5000 m overvoltage category III
Electrical Shock Protection Class class I
Electromagnetic Emission
  • conducted emissions EN 61000-6-3
  • radiated emissions EN 61000-6-4
Documents
Royal Wholesale Electric

5.0

Powered by