Well-Guard pumping plant panels are designed for pumping applications. These panels provide extra space for field installation of auxiliary equipment. These panels use Type S non-reversing magnetic starters. Panel has a LLL36600U31X thermal-magnetic circuit breaker. This panel has a 3 pole NEMA Size 5 non-reversing starter that has a 270 ampere rating. This NEMA Size 5 starter has maximum of 200 HP rating three phase. This non-reversing NEMA motor starter has a Motor Logic overload relay with a 90A to 270A range to sense over current conditions. This NEMA starter has a 100 kA maximum SCCR (Short Circuit Current Rating) per UL508A when protected by an appropriate circuit breaker or fuse. The starters in these panels are available with a wide variety of replaceable coil voltages. The starter in this device has a 440/480 VAC 50/60 Hz operating coil wired for common control. A painted sheet steel NEMA 3R rainproof enclosure is used to protect this starter. Enclosure is 75.50 inches tall, 22.00 inches wide and 17.55 inches deep. A wide variety of accessories are available for Type S starters. This pump panel is supplied with a START momentary push button and a HAND/OFF/AUTO selector switch. These NEMA pump panels with Type S starters are UL listed and marked Suitable for use as Service Equipment. They are also CSA certified.

Brand: Schneider Electric

Add to Quote Catalogue
Specifications
Product Name Well-Guard Control
Device Application pumping
Device Short Name class 8940 type X
Warranty 18 months
Thermal Overload Type Motor Logic solid state class 10/20
Disconnector Device Type associated circuit breaker
Height 1892 mm
Control Type
  • selector switch HAND-OFF-AUTO)
  • push-button START)
Nema Size 5
Device Mounting surface
Circuit Breaker Type LLL
Maximum Horse Power Rating 200-200 hp 480 V AC, 3 phase
[Uc] Control Circuit Voltage
  • 480 V AC 60 Hz
  • 440 V AC 50 Hz
Electrical Connection screw terminal
Line Rated Current 270 A
Protection Type
  • overload
  • phase loss
  • phase unbalance
Control Circuit common control circuit
Width 597 mm
Depth 446 mm
Circuit Breaker Ct Rating 400 A
Permissible Voltage 600 V AC
Number Of Poles 3
China Rohs Regulation Product out of China RoHS scope. Substance declaration for your information.
Eu Rohs Directive Under investigation
California Proposition 65 WARNING: This product can expose you to chemicals including: Lead and lead compounds, which is known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov
Product Certifications
  • UL Listed
  • NEMA
Nema Degree Of Protection NEMA 3R
Enclosure Type weatherproof enclosure indoor/outdoor