Type S NEMA motor starters are used for full voltage starting and stopping of AC squirrel cage motors. Type S motor starters have ratings up to 810 amperes. This 3 pole NEMA Size 3 non-reversing starter has a 90 ampere rating. This NEMA Size 3 motor starter has 3 phase ratings of 25 HP at 200 VAC, 30 HP at 230 VAC and 50 HP at 460 and 575 VAC. This non-reversing NEMA motor starter has a Motor Logic overload relay with a 30A to 90A range to sense over current conditions. This NEMA starter has a 100 kA maximum SCCR (Short Circuit Current Rating) per UL508A when protected by an appropriate circuit breaker or fuse. Type S motor starters are available with replaceable coils in a wide variety of voltages. This starter has a 110/120 VAC 50/60 Hz operating coil wired for separate control. This NEMA starter is an open device without an enclosure. This starter is 11.09 inches tall, 6.49 inches wide and 6.50 inches deep. A wide variety of accessories are available for Type S starters. This starter is supplied with one normally open and one normally closed external interlock. Type S non-reversing NEMA motor starters are UL listed and CSA certified.
Brand: Schneider Electric
Add to Quote CatalogueMotor Starter Type | non reversing |
---|---|
Range Of Product | S |
Product Or Component Type | motor starter |
Warranty | 18 months |
Local Signalling | without pilot light |
Thermal Overload Type | solid state Motor Logic class 10/20 |
Height | 282 mm |
Auxiliary Contact Composition | 1 NO + 1 NC |
Nema Size | 3 |
[Uc] Control Circuit Voltage |
|
Poles Description | 3P |
Rated Power In Hp |
|
Electrical Connection | screw clamp terminals |
Line Rated Current | 90 A |
Control Type | no control units |
Control Circuit | separate control circuit |
Width | 152 mm |
Depth | 165 mm |
Phase | 3 phase |
[Ue] Rated Operational Voltage | 600 V AC |
China Rohs Regulation | Product out of China RoHS scope. Substance declaration for your information. |
Eu Rohs Directive | Not compliant |
Reach Regulation | Reference contains Substances of Very High Concern above the threshold |
California Proposition 65 | WARNING: This product can expose you to chemicals including: Lead and lead compounds, which is known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov |
Product Certifications |
|
Nema Degree Of Protection | not rated (open device) |