56205 – Residual current protection relay, VigiPacT RH10P, 300mA, 12/24VAC 50/60Hz, 12/48VDC, front panel mounting
56205
Residual current protection relay, VigiPacT RH10P, 300mA, 12/24VAC 50/60Hz, 12/48VDC, front panel mounting
Specifications
Type Of Setting none
Reset manual reset
Earth Leakage Current 0.3-0.3 A
Mounting Support front panel
Range Compatibility
  • VigiPacT TOA earth leakage current sensor
  • VigiPacT A earth leakage current sensor
  • VigiPacT L earth leakage current sensor
Earth-Leakage Protection Class type A
Network Rated Voltage
  • 1000-1000 V - AC 50/60 Hz maximum)
  • 1000-1000 V - AC 400 Hz maximum)
[Ithe] Conventional Enclosed Thermal Current 8 A
Earthing System
  • IT
  • TT
  • TN-S
Relay Application protection relay
Product Or Component Type residual current protection relay
Range VigiPacT
Residual Earth-Leakage Time Delay Adjustment Type instantaneous
Residual Earth-Leakage Sensitity Adjustment Type fixed
Power Consumption In Va 4 VA
[Us] Rated Supply Voltage
  • 12...24 V AC 50/60 Hz 55...120 %
  • 12...48 V DC 55...120 %
[Uimp] Rated Impulse Withstand Voltage 8 kV
Minimum Load 10 mA 12 V
Device Short Name RH10P
Warranty 18 months
Ik Degree Of Protection IK07 EN 50102
Mechanical Robustness
  • fire resistance IEC 60695-2-1
  • IK protection 2 joulesIK07 EN 50102
  • vibrations 13.2...100 Hz0.7 g
  • vibrations 2...13.2 Hz+/- 1 mm
Height 72 mm
Type Of Measurement earth fault current internal measurement 80...100 %
Net Weight 0.3 kg
Tamperproof Of Settings protected by sealable cover
Wire Stripping Length
  • auxiliary power supply 7 mm
  • fault 7 mm
  • relay test and fault reset 7 mm
  • sensor 7 mm
  • voltage presence 7 mm
Connections - Terminals
  • auxiliary power supply terminal block 0.2-2.5 mm² flexible AWG 24...AWG 12
  • auxiliary power supply terminal block 0.2-2.5 mm² rigid AWG 24...AWG 12
  • auxiliary power supply terminal block 0.25-2.5 mm² flexible AWG 24...AWG 12
  • fault terminal block 0.2-2.5 mm² flexible AWG 24...AWG 12
  • fault terminal block 0.2-2.5 mm² rigid AWG 24...AWG 12
  • fault terminal block 0.25-2.5 mm² flexible AWG 24...AWG 12
  • relay test and fault reset terminal block 0.2-2.5 mm² flexible AWG 24...AWG 12
  • relay test and fault reset terminal block 0.2-2.5 mm² rigid AWG 24...AWG 12
  • relay test and fault reset terminal block 0.25-2.5 mm² flexible AWG 24...AWG 12
  • sensor terminal block 0.2-2.5 mm² flexible AWG 24...AWG 12
  • sensor terminal block 0.2-2.5 mm² rigid AWG 24...AWG 12
  • sensor terminal block 0.25-2.5 mm² flexible AWG 24...AWG 12
  • voltage presence terminal block 0.2-2.5 mm² flexible AWG 24...AWG 12
  • voltage presence terminal block 0.2-2.5 mm² rigid AWG 24...AWG 12
  • voltage presence terminal block 0.25-2.5 mm² flexible AWG 24...AWG 12
Cut-Out Dimensions 68 x 68 mm
Ip Degree Of Protection
  • on front face IP40 EN/IEC 60529
  • on side parts IP30 EN/IEC 60529
  • on connection terminals IP20 EN/IEC 60529
Test Function
  • remote test
  • local
Monitoring
  • electronics continuous)
  • power supply continuous)
  • relay/sensor link continuous)
Width 72 mm
Depth 78 mm
Tightening Torque
  • auxiliary power supply 0.6-0.6 N.m
  • fault 0.6-0.6 N.m
  • relay test and fault reset 0.6-0.6 N.m
  • sensor 0.6-0.6 N.m
  • voltage presence 0.6-0.6 N.m
Rohs Exemption Information Yes
Mercury Free Yes
Environmental Disclosure ENVPEP060202EN
Sustainable Offer Status Green Premium product
Reach Regulation Reference contains Substances of Very High Concern above the threshold
California Proposition 65 WARNING: Cancer and Reproductive Harm - www.P65Warnings.ca.gov
Weee The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
China Rohs Regulation Product out of China RoHS scope. Substance declaration for your information.
Circularity Profile ENVEOLI100416
Eu Rohs Directive Compliant
Ambient Air Temperature For Operation -35-70 °C
Electromagnetic Compatibility
  • conducted and radiated emissionsB CISPR 11
  • conducted radio-frequency immunity test3 IEC 61000-4-6
  • electrostatic discharge immunity test4 IEC 61000-4-2
  • high-energy conducted susceptibility4 IEC 61000-4-5
  • low-energy conducted susceptibility4 IEC 61000-4-4
  • radiated susceptibility3 IEC 61000-4-3
Pollution Degree 3 IEC 60664-1
Ambient Air Temperature For Storage -55-85 °C
Relative Humidity 95-95 % 55-55 °C
Electrical Shock Protection Class class II
Overvoltage Category IV