9805.10003304
5 kV 133%/8 kV 100% Power, Shielded, 3/C VFD
  • CCW armor provides an impervious barrier to moisture, gas and liquids and meets grounding requirements of UL 1072 and the NEC
  • Triple Extrusion: The strand shield, EPR insulation and insulation shield are all extruded in one operation
  • General Cable’s EPR insulation system has outstanding corona resistance and high dielectric strength, and it provides electrical stability under stress
  • Meets cold bend at -55°C
  • 105°C continuous operating temperature, wet or dry
  • 140°C emergency rating
  • 250°C short circuit rating

Brand: Prysmian Group

Add to Quote
Description
Description 5 kV 133%/8 kV 100% Power, Shielded, 3/C VFD
Long Description CCW® Armored Power, 5 kV 133%/8 kV 100%, Shielded, 3/C VFD
Features
  • CCW armor provides an impervious barrier to moisture, gas and liquids and meets grounding requirements of UL 1072 and the NEC
  • Triple Extrusion: The strand shield, EPR insulation and insulation shield are all extruded in one operation
  • General Cable’s EPR insulation system has outstanding corona resistance and high dielectric strength, and it provides electrical stability under stress
  • Meets cold bend at -55°C
  • 105°C continuous operating temperature, wet or dry
  • 140°C emergency rating
  • 250°C short circuit rating
Applications
  • Variable Frequency Drives: 3-conductor CCW armored cables with three (3) symmetrical grounding wires are the preferred wiring method for use with AC motors controlled by pulse-width modulated inverters in VFD applications
  • CCW armored medium-voltage power cables offer an economical, rugged and reliable alternative to labor-intensive cable in conduit wiring methods
  • For use on feeders and branch circuits for power distribution systems per NEC Articles 328 and 330
  • For use in Class I, II and III, Divisions 1 and 2; and Class I, Zones 1 and 2 hazardous locations per NEC Articles 501, 502, 503 and 505
  • Installed on metal racks, troughs, in raceways, in cable trays or secured to supports spaced not more than
  • six feet apart
  • Installed in both exposed and concealed work, wet or dry locations, directly buried or embedded in concrete
  • Recognized for use on fixed or floating offshore petroleum facilities as recommended by the American Petroleum Institute
Compliances
  • Design Adherence:
  • ICEA S-93-639/WC74, 5-46 kV
  • Shielded Power Cables
  • AEIC CS8 Specification for Shielded Power Cable, 5 – 46 kV
  • UL 1072 Medium-Voltage Power Cables
  • UL 1569 Metal Clad Cables
  • UL 2225 Cables and Cable Fittings for Use in Hazardous Locations
  • UL 1309 Marine Shipboard Cable
  • CSA C68.10
  • Flame Tests:
  • ICEA T-29-520 (210,000 BTU/hr)
  • IEEE 383 (70,000 BTU/hr)
  • CSA FT4
  • IEEE 1202 (70,000 BTU/hr)
  • UL 1581 (70,000 BTU/hr)
  • IEC 60332-3 Cat. A
  • Compliances:
  • UL Type MV-105 or UL Type MC-HL, SUN RES, CT USE, DIR BUR, -40°C, FT4, UL File # E90501
  • UL Listed Marine Shipboard, UL File # E85994
  • CSA Type HL, SR, FT4, -40˚C, CSA File # 27161
  • American Bureau of Shipping (ABS) Listed for CWCMC
Product Construction
Spec Number 9805
Specifications
Catalog Number 9805.10003304
Cond. Size
  • 1000 (61/W) (507 mm²) (Awg/Kcmil)
No. Of cond. 3
Insulation Thickness
  • 115 (Inches)
  • 2.9 (Mm)
Bare Ground
  • 1.34 (Awg)
Nominal Core O.D.
  • 34.0 (Inches)
  • 3 x #4 (Mm)
Nominal Armor O.D.
  • 3.43 (Inches)
  • 87.1 (Mm)
Jacket Thickness
  • 3.76 (Mils)
  • 95.5 (Mm)
Nominal Overall O.D.
  • 85 (Inches)
  • 2.16 (Mm)
Approximate Net Weight
  • 3.94 (Lbs/1000 Ft)
  • 100.1 (Kg/1000 M)
Ampacity
  • 13,051 (In Air)
  • 19,422 (Direct Burial)