Electrical distributor of high quality products to the LA and Orange County markets

Call Us Today To get a Quote
9675.25003308 – 1000 V Power, 3/C VFD
9675.25003308
1000 V Power, 3/C VFD
  • 90°C, 1000 V wet or dry XLPE insulation and three (3) symmetrical grounding wires, recommended
  • for use with pulse-width modulated AC drives
  • XLPE insulation has a dielectric constant less than 3.0 to withstand momentary voltage spikes common with VFD applications
  • CCW armor provides an impervious barrier to moisture, gas and liquids
  • CCW armor provides EMI shielding performance
  • Factory assembled and tested cable for use as an alternative to cable in conduit wiring systems
  • Meets cold impact at -40°C
  • 90˚C continuous operating temperature, wet or dry
  • 130˚C emergency rating
  • 250˚C short circuit rating

Brand: Prysmian Group

Add to Quote
Description
Description 1000 V Power, 3/C VFD
Long Description
  • CCW® Armored Power, 1000 V, 3/C VFD
  • CSA Type RA90, XLPE, 1000 V, 90°C, Cable Tray Use, Sunlight-Resistant Direct Burial, FT4, -40°C, AG14, HL
Features
  • 90°C, 1000 V wet or dry XLPE insulation and three (3) symmetrical grounding wires, recommended
  • for use with pulse-width modulated AC drives
  • XLPE insulation has a dielectric constant less than 3.0 to withstand momentary voltage spikes common with VFD applications
  • CCW armor provides an impervious barrier to moisture, gas and liquids
  • CCW armor provides EMI shielding performance
  • Factory assembled and tested cable for use as an alternative to cable in conduit wiring systems
  • Meets cold impact at -40°C
  • 90˚C continuous operating temperature, wet or dry
  • 130˚C emergency rating
  • 250˚C short circuit rating
Applications
  • Variable Frequency Drives: 3-conductor CCW armored cables with three (3) symmetrical grounding wires are the preferred wiring method for use with AC motors controlled by pulse-width modulated inverters in VFD applications
  • CCW armored cables offer an economical, rugged and reliable alternative to labor-intensive cable in conduit wiring methods
  • For use in industrial and commercial installations including hazardous locations in accordance with the CEC
  • Can be installed in wet or dry locations, indoors or outdoors, in cable trays, in a raceway, or direct buried in accordance with the CEC
Compliances
  • Design Adherence:
  • CSA C22.2 No. 38 Thermoset-Insulated Wires and Cables
  • CSA C22.2 No. 123 Metal Sheathed Cables
  • CSA C22.2 No. 174 Cables and Cable Glands for Use in Hazardous Locations
  • Flame Tests:
  • CSA FT4
  • ICEA T-29-520 (210,000 BTU/hr)
  • IEEE 383 (70,000 BTU/hr)
  • IEEE 1202 (70,000 BTU/hr)
  • Compliances:
  • CSA Certified Type RA90, XLPE, HL, SR, FT4, AG14 and -40°C, CSA File # 7319
  • RoHS Compliant
Product Construction
Spec Number 9675
Conductor
  • Bare annealed copper per ASTM B3
  • Sizes 10 AWG and smaller are Class B compressed stranding per ASTM B8
  • Sizes 8 AWG and larger are compact stranding per ASTM B496
Insulation
  • Cross-linked Polyethylene (XLPE) insulation rated 1000 Volts, RW90 per CSA C22.2 No. 38
  • Sizes 2 AWG and smaller utilize a single color insulation: black, red and blue
  • Sizes 1 AWG and larger utilize black insulation with printed number/color, 1-black, 2-red, 3-blue
Grounding Conductor(s):
  • Class B stranded bare annealed copper per ASTM B3 and B8
  • Three (3) symmetrical grounding wires are sized in accordance with CEC Table 16
Cable Assembly_
  • Three symmetrical grounding wires are cabled within the interstices of the phase conductors
  • Non-hygroscopic fillers when required
  • A binder tape is applied over the cabled core
CCW Armor Impervious, continuously welded and corrugated aluminum alloy sheath per C22.2 No. 123
Jacket
  • Flame-retardant, moisture- and sunlight-resistant Polyvinyl Chloride (PVC), black
  • Meets CSA Low Gas Emission requirements, AG14
Specifications
Catalog Number 9675.25003308
Cond. Size
  • 250 (37/W) (127 mm²) (Awg/Kcmil)
No. Of cond. 3
Insulation Thickness
  • 90 (Inches)
  • 2.29 (Mm)
Bare Ground
  • 3 x #8 (Awg)
Nominal Core O.D.
  • 1.49 (Inches)
  • 37.8 (Mm)
Nominal Armor O.D.
  • 1.90 (Inches)
  • 48.2 (Mm)
Jacket Thickness
  • 50 (Mils)
  • 1.27 (Mm)
Nominal Overall O.D.
  • 2.01 (Inches)
  • 51.1 (Mm)
Approximate Net Weight
  • 3,380 (Lbs/1000 Ft)
  • 5,030 (Kg/1000 M)
Min. Bend Radius
  • 24.1 (Inches)
  • 612 (Mm)
90°C Ampacity @ 30°Cambient 290
Documents
Royal Wholesale Electric

5.0

Powered by

Based on 2 User Reviews