Electrical distributor of high quality products to the LA and Orange County markets

Call Us Today To get a Quote
13373.035300 – Anaconda® Brand Type VFD-BGC Power, Shielded Round Portable w/Extensible Ground-Check, EPR/CPE – 2000 Volts
13373.035300
Anaconda® Brand Type VFD-BGC Power, Shielded Round Portable w/Extensible Ground-Check, EPR/CPE - 2000 Volts
  • Flexible overall shield provides shock hazard protection
  • Symmetrical grounding system does not produce induced voltages when operating in a balanced three-phase system and minimizes common mode current in PWM drive systems
  • Enhanced ground-check conductor has longer flex life and durability
  • Excellent heat, moisture, steam, oil, chemical and radiation resistance
  • Flexible for easy handling
  • Resists cutting, impact, abrasion, flame and sunlight
  • Excellent thermal stability and physical properties over a broad temperature range
  • Two-layer jacket is reinforced to provide maximum protection from mechanical damage— the cause of most portable cable failures

Brand: Prysmian Group

Add to Quote
Description
Description Anaconda® Brand Type VFD-BGC Power, Shielded Round Portable w/Extensible Ground-Check, EPR/CPE - 2000 Volts
Features
  • Flexible overall shield provides shock hazard protection
  • Symmetrical grounding system does not produce induced voltages when operating in a balanced three-phase system and minimizes common mode current in PWM drive systems
  • Enhanced ground-check conductor has longer flex life and durability
  • Excellent heat, moisture, steam, oil, chemical and radiation resistance
  • Flexible for easy handling
  • Resists cutting, impact, abrasion, flame and sunlight
  • Excellent thermal stability and physical properties over a broad temperature range
  • Two-layer jacket is reinforced to provide maximum protection from mechanical damage— the cause of most portable cable failures
Applications
  • Designed for use as a trailing cable on AC mining equipment:
  • From the inverter to the motor on variable frequency drive (PWM) systems
  • Where radiated EMI is causing interference with nearby systems
  • Where a ground-check conductor is required for fail-safe ground monitoring
  • With wireless ground monitoring systems
Compliances
  • Meets flame test requirements and is accepted for listing by MSHA
  • Approved by the Pennsylvania Department of Environmental Protection
Product Construction
Conductor 2 AWG thru 500 kcmil coated annealed copper, bunched wires, rope-lay-stranded per ASTM B172
Insulation Ethylene Propylene Rubber (EPR) insulation, colored
Grounding Conductor(s): Three coated copper, rope-lay-stranded per ASTM B172
Shield A flexible coated copper braid shield under an aluminum tape provides protection from radiated noise and a low transfer impedance path for the high frequency components of PWM signals
Jacket Reinforced, two-layer, extra-heavy-duty, lead-cured Chlorinated Polyethylene (CPE)
Options
  • Colored jackets are available
  • Anamaxx® jacket
Jacket Marking GENERAL CABLE® ANACONDA® BRAND (SIZE) 3/C TYPE VFD-BGC 2000 VOLTS 07-KA140006 MSHA
Specifications
Catalog Number 13373.035300
No. Of Cond. 3
Cond. Size
  • 3/0 (Awg/kmcil)
Cond. Strand 413
Nominal Insulation Thickness
  • 0.080 (Inches)
  • 2.0 (mm)
Ground Conductor Size
  • 4 (AWG)
Ground-Check Cond. Size
  • 16 (AWG)
Nominal Jacket Thickness
  • 0.170 (Inches)
  • 4.3 (Mm)
Nominal Cable O.D
  • 1.93 (Inches)
  • 49.0 (mm)
Cooper Weight
  • 2149 (lbs/1000 Ft)
  • 1440 (kg/km)
Net Weight
  • 3850 (lbs/1000 ft)
  • 5730 (kg/km)
Ampacity 279