Electrical distributor of high quality products to the LA and Orange County markets

Call Us Today To get a Quote
13349.645300 – Anaconda® Brand Type SHD-GC Power, Shielded Round Portable w/Ground-Check, EPR/CPE – 2000 Volts
13349.645300
Anaconda® Brand Type SHD-GC Power, Shielded Round Portable w/Ground-Check, EPR/CPE - 2000 Volts
  • Flexible insulation shield provides shock hazard protection
  • Excellent heat, moisture, steam, oil, chemical and radiation resistance
  • Flexible for easy handling
  • Resists cutting, impact, abrasion, flame and sunlight
  • Excellent thermal stability and physical properties over a broad temperature range
  • Two-layer jacket is reinforced to provide maximum protection from mechanical damage— the cause of most portable cable failures

Brand: Prysmian Group

Add to Quote
Description
Description Anaconda® Brand Type SHD-GC Power, Shielded Round Portable w/Ground-Check, EPR/CPE - 2000 Volts
Features
  • Flexible insulation shield provides shock hazard protection
  • Excellent heat, moisture, steam, oil, chemical and radiation resistance
  • Flexible for easy handling
  • Resists cutting, impact, abrasion, flame and sunlight
  • Excellent thermal stability and physical properties over a broad temperature range
  • Two-layer jacket is reinforced to provide maximum protection from mechanical damage— the cause of most portable cable failures
Applications
  • Designed for use as trailing cables on AC mining equipment:
  • Where a ground-check conductor is required for fail-safe monitoring
  • With Bretby-type cable handling devices on longwall shearers
  • Where induced voltages in the grounding system will not produce a hazard
  • On low- and medium-voltage AC circuits where shielding is desired or required
Compliances
  • ICEA S-75-381 Portable and Power Feeder Cables for use in mines and similar applications
  • Meets flame test requirements and is accepted for listing by MSHA
  • Approved by the Pennsylvania Department of Environmental Protection
Product Construction
Conductor • 6 AWG thru 500 kcmil coated annealed copper, bunched wires, rope-lay-stranded per ASTM B172
Insulation Ethylene Propylene Rubber (EPR) insulation
Grounding Conductor(s):
  • Coated copper, rope-lay-stranded per ASTM B172
  • Two conductors in contact with the flexible copper braid shield
Jacket Reinforced, two-layer, extra-heavy-duty, lead- cured Chlorinated Polyethylene (CPE)
Options
  • Colored jackets are available
  • TPU (Thermoplastic Polyurethane) jacket
  • Anamaxx® jacket
Jacket Marking GENERAL CABLE® ANACONDA® BRAND (SIZE) 3/C TYPE SHD-GC 2000 VOLTS P-7K-102-045 MSHA
Specifications
Catalog Number 13349.645300
No. Of Cond. 3
Cond. Size
  • 3/0 (Awg/kmcil)
Cond. Strand 413
Nominal Insulation Thickness
  • 0.080 (Inches)
  • 2.0 (mm)
Ground Conductor Size
  • 2 (AWG)
Ground-Check Cond. Size
  • 8 (AWG)
Nominal Jacket Thickness
  • 0.205 (Inches)
  • 5.2 (Mm)
Nominal Cable O.D
  • 2.13 (Inches)
  • 54.1 (mm)
Cooper Weight
  • 2249 (lbs/1000 Ft)
  • 3347 (kg/km)
Net Weight
  • 3890 (lbs/1000 ft)
  • 5789 (kg/km)
Ampacity 279
Documents
Royal Wholesale Electric

5.0

Powered by

Based on 2 User Reviews