TeSys island voltage interface module, 100-690V / 47-63Hz. Connected to a TPRBC bus coupler it measures the mains voltages powering the loads. It provides the voltage values for power and energy calculation, calculates the RMS values and phase sequence. Voltage measurement range 100-690 V +/- 5 %, phase frequency measurement range 47-63 Hz +/- 1 Hz in single phase or 3-phase systems. Mounting on DIN rail together with the other modules of the TeSys island configuration. Multi standards certified (IEC, UL, CSA, CCC, EAC), Green Premium compliant (RoHS/REACh).
Add to Quote CataloguePart Number | TPRVM001 |
---|---|
Country of Origin | ID |
UPC | 606489832889 |
UPC11 | 60648983288 |
EAN | 3606489832889 |
Availability | N |
Lead Time | 16 |
ECCN | EAR99 |
HTs Code | 9030390100 |
RoHS Compliant | Yes |
Discount Schedule | I12 |
Return Indicator | Yes |
Depth | 4.49 inch |
Height | 4.65 inch |
Width | 0.98 inch |
Weight | 0.35 pound |
Range | TeSys |
---|---|
Product Name | TeSys island |
Device Short Name | TPRVM |
Product Or Component Type | Voltage interface module |
Device Presentation | Monitoring of the mains voltage powering the island Reporting of the voltage to the bus coupler to enable power & energy monitoring |
Function Of Module | Monitoring of voltages in single phase systems L-N or L-L Monitoring of voltages in 3-phase systems without neutral N connection Calculation of RMS phase voltages, voltage phase sequence, fundamental frequency Identification of dip and swell events level and duration |
Product Compatibility | TPRBC bus coupler |
Ue Rated Operational Voltage | 690 V AC 47...63 Hz |
Ui Rated Insulation Voltage | 690 V IEC 61010-1 |
Uimp Rated Imp Wstd Voltage | 6 kV IEC 61010-1 |
Overvoltage Category | III |
Monitoring Type | Phase voltage 100...690 V Phase frequency 47...63 Hz Phase sequence |
Measurement Accuracy | Voltage +/- 5 %, Frequency +/- 1 Hz, |
Local Signalling | DS (device status) 1 LED green/red) VS (voltage status) 1 LED green/red) |
Us Rated Supply Voltage | 24 V DC supplied by the bus coupler |
Current Consumption | 2 mA |
Power Dissipation In W | 0.5 W maximum |
Standards | IEC 61010-2-201 UL 61010-2-201 CSA C22.2 No 61010-2-201 |
Product Certifications | CSA UL EAC (pending) |
Mounting Mode | Horizontal and vertical 35 mm symmetrical rail) |
Connections - Terminals | Measuring input removable spring terminal block 3 0.00…0.00 in² (0.2…2.5 mm²) AWG 24...AWG 14)rigid Measuring input removable spring terminal block 3 0.00…0.00 in² (0.2…2.5 mm²) AWG 24...AWG 14)flexible without cable end Measuring input removable spring terminal block 3 0.00…0.00 in² (0.25…2.5 mm²) AWG 22...AWG 14)flexible with cable end |
Width | 0.98 in (25 mm) |
Height | 4.65 in (118 mm) |
Depth | 4.49 in (114 mm) |
Product Weight | 0.35 lb(US) (0.159 kg) |
Ambient Air Temp For Storage | -13…158 °F (-25…70 °C) |
Ambient Air Temp For Op | 14…140 °F (-10…60 °C) |
Relative Humidity | 5…95 % |
Operating Altitude | 0...6561.68 ft (0...2000 m) without derating |
IP Degree Of Protection | IP20 |
Pollution Degree | 2 |
Protective Treatment | TC |
Fire Resistance | 1760 °F (960 °C) UL 94 |
Shock Resistance | 15 gn 11 ms) IEC 60068-2-27 |
Vibration Resistance | 1.5 mm peak to peak 3…13 Hz) IEC 60068-2-6 1 gn 13…200 Hz) IEC 60068-2-6 |
Electromagnetic Compatibility | Electrostatic discharge, level 3 8 kV air, 6 kV contact)EN/IEC 61000-4-2) Radiated RF fields, level 3 10 V/m)EN/IEC 61000-4-3) Fast transients immunity test, level 3 2 kV)EN/IEC 61000-4-4) Surge immunity test, level 3 2 kV)EN/IEC 61000-4-5) |
Category | 22353 - TESYS ISLAND AUXILIARY DEVICES |
Discount Schedule | I12 |
GTIN | 03606489832889 |
Nbr. Of Units In Pkg. | 1 |
Country Of Origin | ID |
EU RoHs Directive | Compliant |
Mercury Free | Yes |
WEEE | The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins. |
Halogen Content Performance | Halogen free plastic parts product |
Warranty | 18 months |