Electrical distributor of high quality products to the LA and Orange County markets

Call Us Today To get a Quote
Variable speed drive ATV71 – 132kW-200HP – 480V – EMC filter-graphic terminal
ATV71HC13N4383
Variable speed drive ATV71 – 132kW-200HP – 480V – EMC filter-graphic terminal
Specifications
Part Number ATV71HC13N4383
Country of Origin CN
UPC 389119213714
UPC11 38911921371
EAN 3389119213714
Availability N
Lead Time 29
UNSPSC 26111503
ECCN 3A225
HTs Code 8504404000
Discount Schedule CP4C
Return Indicator No
Depth 14.84 inch
Height 46.85 inch
Width 13.39 inch
Weight 176.37 pound
Characteristics
Range Of Product Altivar 71
Product Or Component Type Variable speed drive
Product Specific Application Complex, high-power machines
Component Name ATV71
Motor Power kW 132 kW, 3 phase 380...480 V
Motor Power Hp 200 hp, 3 phase 380...480 V
Motor Cable Length 328.08 ft (100 m) shielded cable 656.17 ft (200 m) unshielded cable
Power Supply Voltage 380...480 V - 15...10 %
Network Number Of Phases 3 phase
Line Current 192 A 480 V 3 phase 132 kW / 200 hp 239 A 380 V 3 phase 132 kW / 200 hp
Emc Filter Integrated
Assembly Style With heat sink
Variant Control synchronous motors with speed feedback Reinforced version
Apparent Power 157.3 kVA 380 V 3 phase 132 kW / 200 hp
Prospective Line Isc 35 kA 3 phase
Nominal Output Current 259 A 2.5 kHz 380 V 3 phase 132 kW / 200 hp 259 A 2.5 kHz 460 V 3 phase 132 kW / 200 hp
Max Transient Current 388 A 60 s 3 phase 132 kW / 200 hp 427 A 2 s 3 phase 132 kW / 200 hp
Output Frequency 0.1…500 Hz
Nominal Switching Frequency 2.5 kHz
Switching Frequency 2.5...8 kHz adjustable 2.5...8 kHz with derating factor
Async Motor Control Profile Voltage/frequency ratio (2 or 5 points) ENA (Energy adaptation) system for unbalanced loads Flux vector control (FVC) with sensor (current vector) Sensorless flux vector control (SFVC) (voltage or current vector)
Type Of Polarization No impedance Modbus
Product Destination Asynchronous motors Synchronous motors
Power Supply Voltage Limits 323…528 V
Power Supply Frequency 50...60 Hz - 5...5 %
Power Supply Frequency Limits 47.5...63 Hz
Speed Range 1…100 asynchronous motor in open-loop mode, without speed feedback 1…1000 asynchronous motor in closed-loop mode with encoder feedback 1…1000 synchronous motor in closed-loop mode with encoder feedback 1…50 synchronous motor in open-loop mode, without speed feedback
Speed Accuracy +/- 0.01 % of nominal speed in closed-loop mode with encoder feedback 0.2 Tn to Tn +/- 10 % of nominal slip without speed feedback 0.2 Tn to Tn
Torque Accuracy +/- 15 % in open-loop mode, without speed feedback +/- 5 % in closed-loop mode with encoder feedback
Transient Overtorque 170 % +/- 10 % 60 s every 10 minutes 220 % +/- 10 % 2 s
Braking Torque <= 150 % with braking or hoist resistor 30 % without braking resistor
Sync Motor Control Profile Vector control with speed feedback Vector control without speed feedback
Regulation Loop Adjustable PI regulator
Motor Slip Compensation Adjustable Not available in voltage/frequency ratio (2 or 5 points) Suppressable Automatic whatever the load
Diagnostic Drive voltage 1 LED red)
Output Voltage <= power supply voltage
Insulation Electrical between power and control
Type Of Cable For Mounting In An Enclosure With a NEMA Type1 kit 3 UL 508 cable 104 °F (40 °C), copper 75 °C / PVC With an IP21 or an IP31 kit 3 IEC cable 104 °F (40 °C), copper 70 °C / PVC Without mounting kit 1 IEC cable 113 °F (45 °C), copper 70 °C / PVC Without mounting kit 1 IEC cable 113 °F (45 °C), copper 90 °C / XLPE/EPR
Electrical Connection Terminal 2.5 mm², AWG 14 AI1-/AI1+, AI2, AO1, R1A, R1B, R1C, R2A, R2B, LI1...LI6, PWR) Terminal 2 x 120 mm² L1/R, L2/S, L3/T, U/T1, V/T2, W/T3) Terminal 120 mm² PA, PB) Terminal 2 x 120 mm² PC/-, PO, PA/+)
Tightening Torque 5.31 lbf.in (0.6 N.m) AI1-/AI1+, AI2, AO1, R1A, R1B, R1C, R2A, R2B, LI1...LI6, PWR) 212.42 lbf.in (24 N.m), 212 lb.in L1/R, L2/S, L3/T, U/T1, V/T2, W/T3) 212.42 lbf.in (24 N.m), 212 lb.in PA, PB) 212.42 lbf.in (24 N.m), 212 lb.in PC/-, PO, PA/+)
Supply Internal supply for reference potentiometer (1 to 10 kOhm) 10.5 V DC +/- 5 %, <10 mA overload and short-circuit protection Internal supply 24 V DC 21…27 V), <200 mA overload and short-circuit protection
Analogue Input Number 2
Analogue Input Type AI1-/Al1+ bipolar differential voltage +/- 10 V DC 24 V max 11 bits + sign AI2 software-configurable current 0...20 mA 242 Ohm 11 bits AI2 software-configurable voltage 0...10 V DC 24 V max 30000 Ohm 11 bits
Input Sampling Time 2 ms +/- 0.5 ms AI1-/Al1+) - analog 2 ms +/- 0.5 ms Al2) - analog 2 ms +/- 0.5 ms LI1...LI5) - discrete 2 ms +/- 0.5 ms LI6)if configured as logic input - discrete
Response Time <= 100 ms in STO (Safe Torque Off) AO1 2 ms +/- 0.5 ms analog R1A, R1B, R1C 7 ms +/- 0.5 ms discrete R2A, R2B 7 ms +/- 0.5 ms discrete
Absolute Accuracy Precision +/- 0.6 % AI1-/Al1+) for a temperature variation 60 °C +/- 0.6 % AI2) for a temperature variation 60 °C +/- 1 % AO1) for a temperature variation 60 °C
Linearity Error +/- 0.15 % of maximum value AI1-/Al1+, AI2) +/- 0.2 % AO1)
Analogue Output Number 1
Analogue Output Type AO1 software-configurable logic output 10 V 20 mA AO1 software-configurable current 0...20 mA 500 Ohm 10 bits AO1 software-configurable voltage 0...10 V DC 470 Ohm 10 bits
Discrete Output Number 2
Documents
Royal Wholesale Electric

5.0

Powered by