This Altivar 212 variable speed drive can feed 3-phase asynchronous motors. Its protection index is IP21 and it has a built-in EMC filter. It works at a rated power up to 0.75kW / 1hp and a rated voltage from 380V to 480V AC. Its design is based on eco-energy with a reduction in energy consumption of up to 70% compared to a conventional control system. Thanks to its cable temperature rise reduction technology, the Altivar 212 drive offers immediate, disturbance-free operation avoiding additional options such as a line choke or DC choke to deal with current harmonics. It weighs 2kg and its dimensions are, 107mm wide, 143mm high, 150mm deep. It is specifically designed for the most common fluid management applications in tertiary sector buildings (HVAC) like heating, ventilation, air conditioning and pumping. It conforms to international standards IEC/EN 61800-5-1 and IEC/EN 61800-3 (immunity and conducted and radiated EMC emissions). It is also CE, UL, CSA, C-Tick and NOM certified. The Altivar 212 offers optional motor chokes which can increase the maximum cable lengths between the drive and the motor and limit disturbance at the motor terminals. It is designed to be mounted in vertical position (+/- 10 °) on a panel, thanks to 4 fixing holes. It can also be mounted directly on a 35 mm wide DIN rail, thanks to the kit VW3A31852, to order separately. The Altivar 212 drive can easily be adapted to all building management systems thanks to its numerous functions and communication protocols integrated as standard, Modbus, METASYS N2, APOGEE FLN P1 and BACnet. It is eco-friendly and complies with directives such as RoHS, WEEE, etc.relating to environmental protection.
Add to Quote CataloguePart Number | ATV212H075N4 |
---|---|
Country of Origin | ID |
UPC | 785901694816 |
UPC11 | 78590169481 |
EAN | 3606480322440 |
Availability | N |
Lead Time | 60 |
UNSPSC | 39122001 |
ECCN | EAR99 |
HTs Code | 8504404000 |
Prop 65 | This product can expose you to chemicals including: Lead and lead compounds which is known to the State of California to cause Carcinogen & Reproductive harm. For more information go to www.p65warnings.ca.gov |
RoHS Compliant | Yes |
Discount Schedule | CP4D |
Return Indicator | Yes |
Depth | 5.91 inch |
Height | 5.63 inch |
Width | 4.21 inch |
Weight | 4.41 pound |
Range Of Product | Altivar 212 |
---|---|
Product Or Component Type | Variable speed drive |
Device Short Name | ATV212 |
Product Destination | Asynchronous motors |
Product Specific Application | Pumps and fans in HVAC |
Assembly Style | With heat sink |
Network Number Of Phases | 3 phase |
Motor Power kW | 0.75 kW |
Motor Power Hp | 1 hp |
[Us] Rated Supply Voltage | 380...480 V - 15...10 % |
Supply Voltage Limits | 323…528 V |
Supply Frequency | 50...60 Hz - 5...5 % |
Emc Filter | Class C2 EMC filter integrated |
Line Current | 1.4 A 480 V 1.7 A 380 V |
Apparent Power | 1.6 kVA 380 V |
Prospective Line Isc | 5 kA |
Continuous Output Current | 2.2 A 380 V 2.2 A 460 V |
Max Transient Current | 2.4 A 60 s |
Speed Drive Output Frequency | 0.5…200 Hz |
Nominal Switching Frequency | 12 kHz |
Switching Frequency | 6...16 kHz adjustable 12...16 kHz with derating factor |
Speed Range | 1…10 |
Speed Accuracy | +/- 10 % of nominal slip 0.2 Tn to Tn |
Torque Accuracy | +/- 15 % |
Transient Overtorque | 120 % of nominal motor torque +/- 10 % 60 s |
Async Motor Control Profile | Voltage/frequency ratio, automatic IR compensation (U/f + automatic Uo) Voltage/frequency ratio - Energy Saving, quadratic U/f Voltage/frequency ratio, 2 points Flux vector control without sensor, standard Voltage/frequency ratio, 5 points |
Regulation Loop | Adjustable PI regulator |
Motor Slip Compensation | Not available in voltage/frequency ratio motor control Automatic whatever the load Adjustable |
Local Signalling | DC bus energized 1 LED red) |
Output Voltage | <= power supply voltage |
ISOlation | Electrical between power and control |
Type Of Cable | Without mounting kit 1 IEC cable 113 °F (45 °C), copper 90 °C / XLPE/EPR Without mounting kit 1 IEC cable 113 °F (45 °C), copper 70 °C / PVC With UL Type 1 kit 3 UL 508 cable 104 °F (40 °C), copper 75 °C / PVC |
Electrical Connection | VIA, VIB, FM, FLA, FLB, FLC, RY, RC, F, R, RES terminal 0.00 in² (2.5 mm²) / AWG 14 L1/R, L2/S, L3/T terminal 0.01 in² (6 mm²) / AWG 10 |
Tightening Torque | 11.51 lbf.in (1.3 N.m), 11.5 lb.in L1/R, L2/S, L3/T) 5.31 lbf.in (0.6 N.m) VIA, VIB, FM, FLA, FLB, FLC, RY, RC, F, R, RES) |
Supply | Internal supply for reference potentiometer (1 to 10 kOhm) 10.5 V DC +/- 5 %, <10 A overload and short-circuit protection Internal supply 24 V DC 21…27 V), <200 A overload and short-circuit protection |
Analogue Input Number | 2 |
Analogue Input Type | VIA switch-configurable voltage 0...10 V DC 24 V max 30000 Ohm 10 bits VIB configurable voltage 0...10 V DC 24 V max 30000 Ohm 10 bits VIB configurable PTC probe 0...6 probes 1500 Ohm VIA switch-configurable current 0...20 mA 250 Ohm 10 bits |
Sampling Duration | 2 ms +/- 0.5 ms F discrete 2 ms +/- 0.5 ms R discrete 2 ms +/- 0.5 ms RES discrete 3.5 ms +/- 0.5 ms VIA analog 22 ms +/- 0.5 ms VIB analog |
Response Time | FM 2 ms +/- 0.5 ms analog FLA, FLC 7 ms +/- 0.5 ms discrete FLB, FLC 7 ms +/- 0.5 ms discrete RY, RC 7 ms +/- 0.5 ms discrete |
Accuracy | +/- 0.6 % VIA) for a temperature variation 60 °C +/- 0.6 % VIB) for a temperature variation 60 °C +/- 1 % FM) for a temperature variation 60 °C |
Linearity Error | VIA +/- 0.15 % of maximum value input VIB +/- 0.15 % of maximum value input FM +/- 0.2 % output |
Analogue Output Number | 1 |
Analogue Output Type | FM switch-configurable voltage 0...10 V DC 7620 Ohm 10 bits FM switch-configurable current 0...20 mA 970 Ohm 10 bits |
Discrete Output Number | 2 |
Discrete Output Type | Configurable relay logic FLA, FLC) NO - 100000 cycles Configurable relay logic FLB, FLC) NC - 100000 cycles Configurable relay logic RY, RC) NO - 100000 cycles |
Minimum Switching Current | 3 mA 24 V DC configurable relay logic |
Maximum Switching Current | 5 A 250 V AC resistive cos phi = 1 L/R = 0 ms FL, R) 5 A 30 V DC resistive cos phi = 1 L/R = 0 ms FL, R) 2 A 250 V AC inductive cos phi = 0.4 L/R = 7 ms FL, R) 2 A 30 V DC inductive cos phi = 0.4 L/R = 7 ms FL, R) |
Discrete Input Type | F programmable 24 V DC level 1 PLC 4700 Ohm R programmable 24 V DC level 1 PLC 4700 Ohm RES programmable 24 V DC level 1 PLC 4700 Ohm |
Discrete Input Logic | Positive logic (source) F, R, RES), <= 5 V, >= 11 V Negative logic (sink) F, R, RES), >= 16 V, <= 10 V |
Accel And Decel Ramps | Automatic based on the load Linear adjustable separately from 0.01 to 3200 s |