TeSys U standard control unit to be inserted in power bases LUB12, LUB32, LUB38 to form a TeSys U starter controller, for 3-phase motor applications up to 5.5kW@400V. It provides full protection to motors with a rated current Ir 3-12A (Ir adjustable), overload tripping class 10, short circuit at 13 x Irmax, overcurrent at 14.2 x Ir, phase loss, insulation fault (protection of equipment only). To be used with a 24V DC voltage for the control of the starter (through the control terminals A1/A2 located in the power base). Certified when used in conjunction with a LUB power base (IEC, UL, CSA, CCC, EAC, Marine), Green Premium compliant (RoHS/REACh).
Add to Quote CataloguePart Number | LUCA12BL |
---|---|
Country of Origin | FR |
UPC | 785901221906 |
UPC11 | 78590122190 |
EAN | 3389110363845 |
Availability | S |
Lead Time | 3 |
UNSPSC | 39121521 |
ECCN | EAR99 |
HTs Code | 8536308000 |
RoHS Compliant | Yes |
Discount Schedule | I11 |
Return Indicator | Yes |
Depth | 2.36 inch |
Height | 2.60 inch |
Width | 1.77 inch |
Weight | 0.30 pound |
Range Of Product | TeSys U |
---|---|
Range | TeSys |
Product Name | TeSys U |
Device Short Name | LUCA |
Product Or Component Type | Standard control unit |
Device Application | Motor control Motor protection |
Product Specific Application | Basic protection requirements for motor starters: overload and short-circuit |
Main Function Available | Earth fault protection Protection against overload and short-circuit Protection against phase failure and phase imbalance Manual reset |
Product Compatibility | Power base LUB12 Power base LUB32 Power base LUB38 Power base LUB120 Power base LUB320 Power base LUB380 Reversing contactor breaker LU2B12BL Reversing contactor breaker LU2B32BL Reversing contactor breaker LU2B38BL |
Ue Rated Operational Voltage | 690 V AC |
Network Frequency | 40...60 Hz |
Load Type | 3-phase motor self-cooled |
Utilisation Category | AC-43 AC-44 AC-41 |
Motor Power kW | 5.5 kW 400...440 V AC 50/60 Hz 5.5 kW 500 V AC 50/60 Hz 9 kW 690 V AC 50/60 Hz |
Rated Motor Current Adjustment Range | 3…12 A |
Thermal Overload Class | Class 10 40…60 Hz -13…158 °F (-25…70 °C) IEC 60947-6-2 Class 10 40…60 Hz -13…158 °F (-25…70 °C) UL 508 |
Tripping Threshold | 14.2 x Ir +/- 20 % |
Phase Failure Sensitivity | Yes |
[Uc] Control Circuit Voltage | 24 V DC |
Ctrl Circuit Voltage Limits | 20...27 V DC 24 V in operation 14.5 V DC 24 V drop-out |
Typical Current Consumption | 130 mA 24 V DC I maximum while closing with LUB12 220 mA 24 V DC I maximum while closing with LUB32 220 mA 24 V DC I maximum while closing with LUB38 60 mA 24 V DC I rms sealed with LUB12 80 mA 24 V DC I rms sealed with LUB32 80 mA 24 V DC I rms sealed with LUB38 |
Heat Dissipation | 2 W control circuit with LUB12 3 W control circuit with LUB32 3 W control circuit with LUB38 |
Operating Time | 35 ms opening with LUB12 control circuit 35 ms opening with LUB32 control circuit 35 ms opening with LUB38 control circuit 70 ms closing with LUB12 control circuit 70 ms closing with LUB32 control circuit 70 ms closing with LUB38 control circuit |
Standards | EN 60947-6-2 IEC 60947-6-2 UL 60947-4-1, with phase barrier CSA C22.2 No 60947-4-1, with phase barrier |
Product Certifications | CE UL CSA CCC EAC ASEFA ATEX Marine |
Ui Rated Insulation Voltage | 690 V IEC 60947-6-2 600 V UL 60947-4-1 600 V CSA C22.2 No 60947-4-1 |
Uimp Rated Imp Wstd Voltage | 6 kV IEC 60947-6-2 |
Safe Separation Of Circuit | 400 V SELV between the control and auxiliary circuits IEC 60947-1 400 V SELV between the control or auxiliary circuit and the main circuit IEC 60947-1 |
Fixing Mode | Plug-in front face) |
Width | 1.77 in (45 mm) |
Height | 2.60 in (66 mm) |
Depth | 2.36 in (60 mm) |
Product Weight | 0.30 lb(US) (0.135 kg) |
Compatibility Code | LUCA |
IP Degree Of Protection | IP20 front panel and wired terminals IEC 60947-1 IP20 other faces IEC 60947-1 IP40 front panel outside connection zone IEC 60947-1 |
Protective Treatment | TH IEC 60068 |
Ambient Air Temp For Op | -13…158 °F (-25…70 °C) |
Ambient Air Temp For Storage | -40…185 °F (-40…85 °C) |
Operating Altitude | 6561.68 ft (2000 m) |
Fire Resistance | 1760 °F (960 °C) parts supporting live components IEC 60695-2-12 1202 °F (650 °C) IEC 60695-2-12 |
Shock Resistance | 10 gn power poles open IEC 60068-2-27 15 gn power poles closed IEC 60068-2-27 |
Vibration Resistance | 2 gn 5…300 Hz power poles open IEC 60068-2-6 4 gn 5…300 Hz power poles closed IEC 60068-2-6 |
Resist Electrostatic Dischrg | 8 kV 3 in open air IEC 61000-4-2 8 kV 4 on contact IEC 61000-4-2 |
Resistance To Radiated Fields | 9.14 V/m (10 V/m) 3 IEC 61000-4-3 |
Resistance To Fast Transients | 2 kV 3 serial link IEC 61000-4-4 4 kV 4 all circuits except for serial link IEC 61000-4-4 |
Imm To Radioelectric Fields | 10 V IEC 61000-4-6 |
Immunity To Microbreaks | 3 ms |
Immunity To Voltage Dips | 70 % / 500 ms IEC 61000-4-11 |