Specifications
Part Number LP4K06105JW3
Country of Origin FR
UPC 389110498493
UPC11 38911049849
EAN 3389110498493
Availability N
Lead Time 20
ECCN EAR99
HTs Code 8536490065
Discount Schedule I12
Return Indicator No
Depth 2.24 inch
Height 2.28 inch
Width 1.77 inch
Weight 0.52 pound
Characteristics
Range Of Product TeSys K
Range TeSys
Product Or Component Type Contactor
Device Short Name LP4K
Contactor Application Motor control
Utilisation Category AC-4 AC-3
Poles Description 3P
Pole Contact Composition 3 NO
Ie Rated Operational Current 6 A<= 440 V AC AC-3 power circuit
Auxiliary Contact Composition 1 NO
Coil Technology Built-in bidirectional peak limiting diode suppressor
Auxiliary Contacts Type Instantaneous 1 NO
Ctrl Circuit Voltage Limits Operational 0.7...1.30 Uc 122 °F (50 °C)) Drop-out 0.1...0.7 Uc 122 °F (50 °C))
Ui Rated Insulation Voltage Power circuit 600 V UL 508 Power circuit 690 V IEC 60947-4-1 Signalling circuit 690 V IEC 60947-4-1 Signalling circuit 690 V IEC 60947-5-1 Signalling circuit 600 V UL 508 Power circuit 600 V CSA C22.2 No 14 Signalling circuit 600 V CSA C22.2 No 14
Uimp Rated Imp Wstd Voltage 8 kV
Overvoltage Category III
Mounting Support Printed circuit boards
Flame Retardance V1 UL 94 Requirement 2 NF F 16-101 Requirement 2 NF F 16-102
Ue Rated Operational Voltage Power circuit 690 V AC 50/60 Hz Signalling circuit <= 690 V AC 50/60 Hz
Ith Cnvtl Free Air Therm Crrt 20 A 122 °F (50 °C) power circuit 10 A 122 °F (50 °C) signalling circuit
Irms Rated Making Capacity 110 A AC power circuit NF C 63-110 110 A AC power circuit IEC 60947 110 A AC signalling circuit IEC 60947
Rated Breaking Capacity 110 A 415 V IEC 60947 110 A 440 V IEC 60947 80 A 500 V IEC 60947 110 A 220...230 V IEC 60947 110 A 380...400 V IEC 60947 70 A 660...690 V IEC 60947
Associated Fuse Rating 25 A gG <= 440 V power circuit 25 A aM power circuit 10 A gG signalling circuit IEC 60947 10 A gG signalling circuit VDE 0660
Average Impedance 3 mOhm - Ith 20 A 50 Hz power circuit
Inrush Power In W 1.8 W 68 °F (20 °C))
Hold-In Power Consumption W 1.8 W 68 °F (20 °C)
Operating Time 10...20 ms coil de-energisation and NO opening 30...40 ms coil energisation and NO closing
Safety Reliability Level B10d = 1369863 cycles contactor with nominal load EN/ISO 13849-1 B10d = 20000000 cycles contactor with mechanical load EN/ISO 13849-1
Mechanical Durability 30 Mcycles
Operating Rate 3600 cyc/h
Minimum Switching Current 5 mA signalling circuit
Minimum Switching Voltage 17 V signalling circuit
Insulation Resistance > 10 MOhm signalling circuit
Height 2.28 in (58 mm)
Width 1.77 in (45 mm)
Depth 2.24 in (57 mm)
Product Weight 0.52 lb(US) (0.235 kg)
Product Certifications CSA UL
Ambient Air Temp For Op -13…122 °F (-25…50 °C)
Ambient Air Temp For Storage -58…176 °F (-50…80 °C)
Operating Altitude 6561.68 ft (2000 m) without derating
Category 22321 - CTR,K-LINE,DC,OPEN,NONREV
Discount Schedule I12
GTIN 03389110498493
Nbr. Of Units In Pkg. 1
Country Of Origin FR
Warranty 18 months
Documents
Royal Wholesale Electric

5.0

Powered by