GV7RS50 is a TeSys GV7R motor circuit breaker from Schneider Electric. It ensures thermal-magnetic protection for motors 18.5-22kW@400V with high breaking capacity Icu 70kA. Start-stop control by rocker lever guaranteed for 30 000 cycles AC-3 415V. GV7RS50 is a TeSys GV7R motor circuit breaker from Schneider Electric designed for motor applications 18.5-22kW@400V. It fulfills thermal-magnetic protection with a thermal setting range 30-50A, magnetic tripping at 12-14xIn and breaking capacity Icu 70kA@400V. Start-stop control by rocker lever guaranteed for 30 000 cycles AC-3 415V. Available worldwide, it is multi-standards certified (IEC, UL, CSA, Marine). Complete motor protection in a single device , short-circuit, overload, disconnection. Associated with a TeSys contactor, it ensures a complete type 1 or type 2 Motor Starter solution. For large industrial or building LV distribution networks thanks to a high 70kA breaking capacity. Power connections with screw clamp terminals. Manual control with rocker lever for Start / Stop, padlockable with accessory (GV7V). Possible integration of auxiliary contacts (GV7AB, GV7AD, GV7AE) for status and tripping signaling. Possible integration of undervoltage or shunt tripping units (GV7AU, GV7AS).
Add to Quote CataloguePart Number | GV7RS50 |
---|---|
Country of Origin | CN |
UPC | 785901294351 |
UPC11 | 78590129435 |
GTIN | 3389110602609 |
EAN | 3389110602609 |
Availability | N |
Lead Time | 19 |
UNSPSC | 39121521 |
ECCN | EAR99 |
HTs Code | 8536504000 |
Discount Schedule | I11 |
Return Indicator | No |
Depth | 4.37 inch |
Height | 6.34 inch |
Width | 4.13 inch |
Weight | 4.44 pound |
Gross Weight | 4.21 |
Gross Weight UOM | Lbs |
Pkg Length | 6.90 |
Pkg Length UOM | In |
Pkg Height | 5.52 |
Pkg Height UOM | In |
Pkg Width | 4.53 |
Pkg Width UOM | In |
Range | TeSys |
---|---|
Product Name | TeSys GV7 |
Device Short Name | GV7R |
Device Application | Motor |
Poles Description | 3P |
Network Type | AC |
Utilisation Category | AC-3 IEC 60947-4-1 |
Network Frequency | 50/60 Hz IEC 60947-4-1 |
Breaking Capacity | 50 kA Icu 500 V AC 50/60 Hz IEC 60947-2 65 kA Icu 440 V AC 50/60 Hz IEC 60947-2 100 kA Icu 220/240 V AC 50/60 Hz IEC 60947-2 70 kA Icu 380/415 V AC 50/60 Hz IEC 60947-2 10 kA Icu 660/690 V AC 50/60 Hz IEC 60947-2 |
Ics Rated Ser Sc Brking Cap | 100 % 440 V AC 50/60 Hz IEC 60947-2 100 % 500 V AC 50/60 Hz IEC 60947-2 100 % 220/240 V AC 50/60 Hz IEC 60947-2 100 % 380/415 V AC 50/60 Hz IEC 60947-2 100 % 660/690 V AC 50/60 Hz IEC 60947-2 |
Thermal Protection Adjustment Range | 30…50 A |
Trip Unit Technology | Thermal-magnetic |
Mounting Mode | By clips By screws |
Mounting Support | Rail Flush Kit for fixing the switchgear Panel mounting |
Mounting Position | Vertical |
Motor Power kW | 22 kW 400...415 V AC 50/60 Hz 30 kW 500 V AC 50/60 Hz 30 kW 660...690 V AC 50/60 Hz |
Control Type | Rocker lever |
Ue Rated Operational Voltage | 690 V AC 50/60 Hz IEC 60947-2 |
Ui Rated Insulation Voltage | 750 V AC 50/60 Hz IEC 60947-2 |
Ith Cnvtl Free Air Therm Crrt | 50 A IEC 60947-4-1 |
Uimp Rated Imp Wstd Voltage | 8 kV IEC 60947-2 |
Power Dissipation Per Pole | 5 W |
Power Dissipation Per Pole | 5 W |
Mechanical Durability | 50000 cycles |
Electrical Durability | 30000 cycles AC-3 440 V In 50000 cycles AC-3 440 V In/2 |
Operating Rate | 25 cyc/h |
Rated Duty | Continuous IEC 60947-4-1 |
Connection Pitch | 1.38 in (35 mm) without spreaders 1.77 in (45 mm) with spreaders |
Connections - Terminals | bars cable with lug 0.39 in (10 mm) screw bare cable connectors 0.00…0.15 in² (1.5…95 mm²) |
Tightening Torque | 88.51 lbf.in (10 N.m) screw M6 132.76 lbf.in (15 N.m) bare cable connectors 0.00…0.15 in² (1.5…95 mm²) |
Mechanical Robustness | Shocks 15 Gn for 11 ms IEC 60068-2-27 Vibrations 2.5 Gn, 0...25 Hz IEC 60068-2-6 |
Suitability For ISOlation | Yes IEC 60947-1 |
Phase Failure Sensitivity | Yes IEC 60947-4-1 § 7-2-1-5-2 |
Height | 6.34 in (161 mm) |
Width | 4.13 in (105 mm) |
Depth | 4.37 in (111 mm) |
Product Weight | 4.44 lb(US) (2.015 kg) |
Standards | EN/IEC 60947-1 VDE 0660 NF C 63-120 NF C 79-130 VDE 0113 EN/IEC 60947-2 EN/IEC 60947-4-1 NF C 63-650 |
Product Certifications | DNV UL |
Protective Treatment | TC |
IP Degree Of Protection | IP405 IEC 60529 with terminal shrouds) |
Pollution Degree | 3 |
Ambient Air Temp For Op | -13…158 °F (-25…70 °C) |
Ambient Air Temp For Storage | -67…203 °F (-55…95 °C) |
Fire Resistance | 1760 °F (960 °C) IEC 60695-2-1 |
Operating Altitude | 6561.68 ft (2000 m) |
Category | 22366 - MAN STR PROTECTORS-GV1/GV3 |
Discount Schedule | I11 |
GTIN | 00785901294351 |
Nbr. Of Units In Pkg. | 1 |