Electrical distributor of high quality products to the LA and Orange County markets

Call Us Today To get a Quote
TeSys GV2 Manual Starter and Protector, thermal magnetic circuit protector, toggle switch, 9…14 A, screw clamp terminals
GV2RT16
TeSys GV2 Manual Starter and Protector, thermal magnetic circuit protector, toggle switch, 9…14 A, screw clamp terminals

TeSys GV motor circuit breaker, 3 poles (3P), 14A/690V, for high starting current peak motor applications 5.5kW@400V. It provides a thermal-magnetic protection with a thermal setting range 9-14A, a magnetic tripping level at 20xIn, high breaking capacity Icu 15kA@400V. Connection by screw clamp terminals. Start-stop control by toggle guaranteed for 100 000 cycles AC-3. It can be used for protection of 3-phase transformer applications. Multi standards certified (IEC, UL, CSA, CCC, EAC, Marine), Green Premium compliant (RoHS/REACh).

Add to Quote Catalogue
Specifications
Part Number GV2RT16
Country of Origin FR
UPC 785901072799
UPC11 78590107279
EAN 3389110520699
Availability N
Lead Time 22
UNSPSC 39121521
ECCN EAR99
HTs Code 8536200040
Prop 65 This product can expose you to chemicals including: Antimony oxide & Antimony trioxide which is known to the State of California to cause Carcinogen harm. For more information go to www.p65warnings.ca.gov
RoHS Compliant Yes
Discount Schedule I11
Return Indicator No
Depth 3.09 inch
Height 3.50 inch
Width 1.77 inch
Characteristics
Range TeSys
Product Name TeSys GV2
Device Short Name GV2RT
Device Application Transformer Motor
Trip Unit Technology Thermal-magnetic
Poles Description 3P
Network Type AC
Utilisation Category AC-3 IEC 60947-4-1 Category A IEC 60947-2
Network Frequency 50/60 Hz IEC 60947-4-1
Fixing Mode 35 mm symmetrical DIN rail clipped Panel screwed with adaptor plate)
Operating Position Any position
Motor Power kW 2.2 kW 220/230 V AC 50/60 Hz motor protection high peak current 3 kW 220/230 V AC 50/60 Hz motor protection high peak current 5.5 kW 400/415 V AC 50/60 Hz motor protection high peak current 5.5 kW 440 V AC 50/60 Hz motor protection high peak current 7.5 kW 440 V AC 50/60 Hz motor protection high peak current 7.5 kW 500 V AC 50/60 Hz motor protection high peak current 9 kW 690 V AC 50/60 Hz motor protection high peak current 11 kW 690 V AC 50/60 Hz motor protection high peak current 4 kW 230/240 V AC 50/60 Hz transformer protection 6.3 kW 400/415 V AC 50/60 Hz transformer protection 10 kW 690 V AC 50/60 Hz transformer protection 12.5 kW 690 V AC 50/60 Hz transformer protection
Breaking Capacity 3 kA Icu 690 V AC 50/60 Hz IEC 60947-2 15 kA Icu 400/415 V AC 50/60 Hz IEC 60947-2 8 kA Icu 440 V AC 50/60 Hz IEC 60947-2 6 kA Icu 500 V AC 50/60 Hz IEC 60947-2 100 kA Icu 220/230 V AC 50/60 Hz IEC 60947-2
Control Type Toggle
In Rated Current 14 A
Thermal Protection Adjustment Range 9…14 A
Magnetic Tripping Current 280 A
Ue Rated Operational Voltage 690 V AC 50/60 Hz IEC 60947-2
Ui Rated Insulation Voltage 690 V AC 50/60 Hz IEC 60947-2
Ith Cnvtl Free Air Therm Crrt 14 A IEC 60947-4-1
Uimp Rated Imp Wstd Voltage 6 kV IEC 60947-2
Power Dissipation Per Pole 2.5 W
Mechanical Durability 100000 cycles
Electrical Durability 100000 cycles AC-3 440 V
Operating Rate 25 cyc/h
Rated Duty Continuous IEC 60947-4-1
Connections - Terminals screw clamp terminals 2 0.00…0.01 in² (1…6 mm²) solid screw clamp terminals 2 0.00…0.01 in² (1.5…6 mm²) flexible without cable end screw clamp terminals 2 0.00…0.01 in² (1…4 mm²) flexible with cable end
Tightening Torque 15.05 lbf.in (1.7 N.m) screw clamp terminals
Suitability For ISOlation Yes IEC 60947-1
Height 3.50 in (89 mm)
Width 1.77 in (45 mm)
Depth 3.09 in (78.5 mm)
Standards EN/IEC 60947-2 EN/IEC 60947-4-1 UL 60947-4-1 CSA C22.2 No 60947-4-1
Product Certifications IECEE CB Scheme UL CSA CCC EAC BV LROS (Lloyds register of shipping)
Protective Treatment TH
IP Degree Of Protection IP20 IEC 60529
IK Degree Of Protection IK04
Ambient Air Temp For Op -4…140 °F (-20…60 °C)
Ambient Air Temp For Storage -40…176 °F (-40…80 °C)
Fire Resistance 1760 °F (960 °C) IEC 60695-2-1
Operating Altitude 6561.68 ft (2000 m)
Category 22367 - MANUAL STR PROTECTOR - GV2
Discount Schedule I11
GTIN 00785901072799
Nbr. Of Units In Pkg. 1
Country Of Origin FR
Green Premium Status Green Premium product
EU RoHs Directive Compliant
Mercury Free Yes
WEEE The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
Documents
Royal Wholesale Electric

5.0

Powered by