Electrical distributor of high quality products to the LA and Orange County markets

Call Us Today To get a Quote
TeSys GV2 and GV3 Manual Starter and Protector, auxiliary contact block, 1 NO or NC, top mount, screw clamp
GVAE1
TeSys GV2 and GV3 Manual Starter and Protector, auxiliary contact block, 1 NO or NC, top mount, screw clamp

TeSys GV auxiliary contact block, for motor circuit breakers GV2 and GV3. 1NO or 1NC instantaneous auxiliary contacts depending on the mounting orientation of the block. Rated for operation up to 2A/240V AC and 1A/60V DC. To be installed on front side of the circuit breaker, connection by screw clamp terminals. Sold in lots of 10 units. Multi standards certified (IEC, UL, CSA, CCC, EAC), Green Premium compliant (RoHS/REACh).

Add to Quote Catalogue
Specifications
Part Number GVAE1
Country of Origin CZ
UPC 785901343424
UPC11 78590134342
EAN 3389110343427
Availability S
Lead Time 3
UNSPSC 39121521
ECCN EAR99
HTs Code 8536509065
Prop 65 This product can expose you to chemicals including: Lead and lead compounds which is known to the State of California to cause Carcinogen & Reproductive harm. For more information go to www.p65warnings.ca.gov
RoHS Compliant Yes
Discount Schedule I11
Return Indicator Yes
Depth 1.14 inch
Height 0.43 inch
Width 1.77 inch
Weight 0.04 pound
Characteristics
Range TeSys
Device Short Name GVAE
Product Or Component Type Auxiliary contact block
Product Compatibility GV2L GV2P GV2RT GV3P GV3L GV2LE GV2ME
Mounting Location Front side
Pole Contact Composition 1 NO/NC
Connections - Terminals screw clamp terminals 1 0.00…0.00 in² (1…2.5 mm²)solid screw clamp terminals 2 0.00…0.00 in² (1…2.5 mm²)solid screw clamp terminals 1 0.00…0.00 in² (0.75…2.5 mm²)flexible without cable end screw clamp terminals 2 0.00…0.00 in² (0.75…2.5 mm²)flexible without cable end screw clamp terminals 1 0.00…0.00 in² (0.75…1.5 mm²)flexible with cable end
Quantity Per Set Set of 10
Ui Rated Insulation Voltage 300 V UL 508 300 V CSA C22.2 No 14 250 V IEC 60947-1
Ue Rated Operational Voltage 24...240 V AC 24...60 V DC
Ith Cnvtl Free Air Therm Crrt 2.5 A
Protection Type GG fuse 10 A GB2CB06 circuit breaker 10 A
Mechanical Durability 100000 cycles
Minimum Switching Current 5 mA
Minimum Switching Voltage 17 V
Rated Opr Power In VA 120 VA 110…120 V AC-15 100000 cycles 120 VA 230…240 V AC-15 100000 cycles 48 VA 24 V AC-15 100000 cycles 60 VA 48 V AC-15 100000 cycles
Rated Opr Power In W 15 W 48 V DC-13 100000 cycles 24 W 24 V DC-13 100000 cycles 9 W 60 V DC-13 100000 cycles
Tightening Torque 12.39 lbf.in (1.4 N.m) screw clamp terminals
Height 0.43 in (11 mm)
Width 1.77 in (45 mm)
Depth 1.14 in (29 mm)
Product Weight 0.04 lb(US) (0.02 kg)
Environmental Characteristic Normal environment
Category 22367 - MANUAL STR PROTECTOR - GV2
Discount Schedule I11
GTIN 00785901343424
Nbr. Of Units In Pkg. 1
Country Of Origin CZ
Green Premium Status Green Premium product
REACh Free Of SVHC Yes
EU RoHs Directive Compliant
Toxic Heavy Metal Free Yes
Mercury Free Yes
WEEE The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
Warranty 18 months
Documents