TeSys F contactor, 3 poles (3NO), 800A/1000V AC-3, for motor applications up to 450kW@400V. Contactor with no coil to allow a later selection and installation (coil to be ordered separately), it provides bolt terminals for bars or cables with lugs. For high operating rates until 600 cycles/hour and environments until 55°C, it procures high reliability and durability. It makes installation and maintenance easy thanks to a drawer for insertion of the selected coil and a large choice of add-on blocks and accessories (to be ordered separately). Multi standards certified (IEC, UL, CSA, CCC, Marine), Green Premium compliant (RoHS/REACh).
Add to Quote CataloguePart Number | LC1F800 |
---|---|
Country of Origin | CZ |
UPC | 785901747079 |
UPC11 | 78590174707 |
EAN | 3389110747072 |
Availability | N |
Lead Time | 21 |
UNSPSC | 39121529 |
ECCN | EAR99 |
HTs Code | 8536490065 |
Prop 65 | This product can expose you to chemicals including: Lead and lead compounds which is known to the State of California to cause Carcinogen & Reproductive harm. For more information go to www.p65warnings.ca.gov |
RoHS Compliant | Yes |
Discount Schedule | I12 |
Return Indicator | No |
Depth | 10.04 inch |
Height | 11.97 inch |
Width | 12.17 inch |
Weight | 41.34 pound |
Range | TeSys |
---|---|
Product Name | TeSys F |
Product Or Component Type | Contactor |
Device Short Name | LC1F |
Contactor Application | Motor control Resistive load |
Utilisation Category | AC-3 AC-1 AC-4 |
Poles Description | 3P |
Power Pole Contact Composition | 3 NO |
Ue Rated Operational Voltage | <= 1000 V AC 50/60 Hz <= 460 V DC |
Ie Rated Operational Current | 1000 A 104 °F (40 °C)) <= 440 V AC AC-1 800 A 131 °F (55 °C)) <= 440 V AC AC-3 |
Motor Power kW | 450 kW 1000 V AC 50/60 Hz AC-3) 450 kW 500 V AC 50/60 Hz AC-3) 475 kW 660...690 V AC 50/60 Hz AC-3) 110 kW 400 V AC 50/60 Hz AC-4) 450 kW 380...400 V AC 50/60 Hz AC-3) 450 kW 415 V AC 50/60 Hz AC-3) 450 kW 440 V AC 50/60 Hz AC-3) 250 kW 220...240 V AC 50/60 Hz AC-3) |
Uc Control Circuit Voltage | 110...400 V AC 40...400 Hz with LX1/LX9 coil 110...400 V DC with LX4 coil 100...250 V AC 50/60 Hz with LXE coil 100...380 V DC with LXE coil |
Uimp Rated Imp Wstd Voltage | 8 kV |
Overvoltage Category | III |
Ith Cnvtl Free Air Therm Crrt | 1000 A 104 °F (40 °C) |
Irms Rated Making Capacity | 8000 A AC IEC 60947-4-1 |
Rated Breaking Capacity | 6400 A IEC 60947-4-1 |
Icw Rated Short-Time Wstd Crrt | 3000 A 104 °F (40 °C) - 3 min 6250 A 104 °F (40 °C) - 10 s 5600 A 104 °F (40 °C) - 30 s 4600 A 104 °F (40 °C) - 1 min 2200 A 104 °F (40 °C) - 10 min |
Associated Fuse Rating | 1000 A gG <= 440 V 800 A aM <= 440 V |
Average Impedance | 0.12 mOhm - Ith 1000 A 50 Hz |
Ui Rated Insulation Voltage | 1000 V IEC 60947-4-1 1500 V VDE 0110 group C |
Power Dissipation Per Pole | 120 W AC-1 77 W AC-3 |
Ctrl Circuit Voltage Limits | Operational 0.85...1.1 Uc AC 40...400 Hz Drop-out 0.3...0.5 Uc AC 40...400 Hz Operational 0.85...1.1 Uc DC Drop-out 0.3...0.5 Uc DC Operational 85...275 V AC 50/60 Hz Drop-out 0...60 V AC 50/60 Hz Operational 85...418 V DC Drop-out 0...45 V DC |
Heat Dissipation | 25 W 2.2…5.5 W |
Operating Time | 60...80 ms closing with LX1/LX9 coil 160...180 ms opening with LX1/LX9 coil 60...80 ms closing with LX4 coil 40...50 ms opening with LX4 coil 40...80 ms closing with LXE coil 6...54 ms opening with LXE coil |
Mounting Support | Plate |
Standards | IEC 60947-1 JIS C8201-4-1 EN 60947-1 IEC 60947-4-1 EN 60947-4-1 |
Product Certifications | CB CSA LROS (Lloyds register of shipping) ABS CCC UL |
Connections - Terminals | Power circuit bar 2 60 x 5 mm Power circuit bolted connection Control circuit screw clamp terminals 1 0.00…0.01 in² (1…4 mm²)flexible without cable end Control circuit screw clamp terminals 2 0.00…0.01 in² (1…4 mm²)flexible with cable end Control circuit screw clamp terminals 1 0.00…0.01 in² (1…4 mm²)flexible with cable end Control circuit screw clamp terminals 2 0.00…0.00 in² (1…2.5 mm²)solid without cable end Control circuit screw clamp terminals 1 0.00…0.01 in² (1…4 mm²) Control circuit screw clamp terminals 2 0.00…0.01 in² (1…4 mm²) |
Tightening Torque | Power circuit 513.34 lbf.in (58 N.m) Control circuit 10.62 lbf.in (1.2 N.m) |
Mechanical Durability | 5 Mcycles |
Inrush Power In VA | 1700 VA, 40...400 Hz cos phi 0.9 (at 68 °F (20 °C))with LX1/LX9 coil 1900 VA (at 68 °F (20 °C))with LX4 coil 460…730 VA, 50/60 Hz cos phi 0.5 (at 68 °F (20 °C))with LXE coil 500…680 VA cos phi 0.5 (at 68 °F (20 °C))with LXE coil |
Hold-In Power Consumption Va | 12 VA 12 VA 7…10 VA 4.0…5.5 VA |
Operating Rate | 600 cyc/h 131 °F (55 °C) |
Compatibility Code | LC1F |
IP Degree Of Protection | IP20 front face with shrouds IEC 60529 IP20 front face with shrouds VDE 0106 |
Protective Treatment | TH |
Ambient Air Temp For Op | 23…131 °F (-5…55 °C) |
Ambient Air Temp For Storage | -76…176 °F (-60…80 °C) |
Ambient Air Temp Around Device | 23…131 °F (-5…55 °C) |
Mechanical Robustness | Vibrations contactor open2 Gn, 5...300 Hz Vibrations contactor closed4 Gn, 5...300 Hz Shocks contactor open6 Gn for 1/2 sine wave (11 ms) Shocks contactor closed15 Gn for 1/2 sine wave (11 ms) |
Height | 11.97 in (304 mm) |
Width | 12.17 in (309 mm) |
Depth | 10.04 in (255 mm) |
Product Weight | 41.34 lb(US) (18.75 kg) |
Category | 22336 - CTR,F-LINE,AC,OPEN,NONREV |
Discount Schedule | I12 |
GTIN | 00785901747079 |
Nbr. Of Units In Pkg. | 1 |
Country Of Origin | CZ |