TeSys F contactor, 3 poles (3NO), 115A/690V AC-3, for motor applications up to 55kW@400V. Contactor with no coil to allow a later selection and installation (coil to be ordered separately), it provides bolt terminals for bars or cables with lugs. For high operating rates until 2400 cycles/hour and environments until 55°C, it procures high reliability and durability. It makes installation and maintenance easy thanks to a drawer for insertion of the selected coil and a large choice of add-on blocks and accessories (to be ordered separately). Multi standards certified (IEC, UL, CSA, CCC, EAC, Marine), Green Premium compliant (RoHS/REACh).
Add to Quote CataloguePart Number | LC1F115 |
---|---|
Country of Origin | CZ |
UPC | 785901122210 |
UPC11 | 78590112221 |
EAN | 3389110122213 |
Availability | S |
Lead Time | 3 |
UNSPSC | 39121529 |
ECCN | EAR99 |
HTs Code | 8536490065 |
Prop 65 | This product can expose you to chemicals including: Lead and lead compounds which is known to the State of California to cause Carcinogen & Reproductive harm. For more information go to www.p65warnings.ca.gov |
RoHS Compliant | Yes |
Discount Schedule | I12 |
Return Indicator | Yes |
Depth | 6.73 inch |
Height | 6.38 inch |
Width | 6.44 inch |
Weight | 8.44 pound |
Range | TeSys |
---|---|
Product Name | TeSys F |
Product Or Component Type | Contactor |
Device Short Name | LC1F |
Contactor Application | Resistive load Motor control |
Utilisation Category | AC-1 AC-4 AC-3 |
Poles Description | 3P |
Power Pole Contact Composition | 3 NO |
Ue Rated Operational Voltage | <= 690 V AC 50/60 Hz |
Ie Rated Operational Current | 200 A 104 °F (40 °C)) <= 440 V AC-1 115 A 131 °F (55 °C)) <= 440 V AC-3 |
Motor Power kW | 55 kW 380...400 V AC 50/60 Hz AC-3) 59 kW 415 V AC 50/60 Hz AC-3) 59 kW 440 V AC 50/60 Hz AC-3) 75 kW 500 V AC 50/60 Hz AC-3) 30 kW 220...240 V AC 50/60 Hz AC-3) 80 kW 660...690 V AC 50/60 Hz AC-3) 18.5 kW 400 V AC 50/60 Hz AC-4) |
Uc Control Circuit Voltage | 24...575 V AC 40...400 Hz with LX9 coil 24...460 V DC with LX4 coil 100...250 V AC 50/60 Hz with LXE coil 100...380 V DC with LXE coil |
Uimp Rated Imp Wstd Voltage | 8 kV |
Overvoltage Category | III |
Ith Cnvtl Free Air Therm Crrt | 200 A 104 °F (40 °C) |
Irms Rated Making Capacity | 1150 A IEC 60947-4-1 |
Rated Breaking Capacity | 920 A IEC 60947-4-1 |
Icw Rated Short-Time Wstd Crrt | 1100 A 104 °F (40 °C) - 10 s 640 A 104 °F (40 °C) - 30 s 520 A 104 °F (40 °C) - 1 min 400 A 104 °F (40 °C) - 3 min 320 A 104 °F (40 °C) - 10 min |
Associated Fuse Rating | 125 A aM <= 440 V 200 A gG <= 440 V |
Average Impedance | 0.37 mOhm - Ith 200 A 50 Hz |
Ui Rated Insulation Voltage | 1000 V IEC 60947-4-1 1500 V VDE 0110 group C |
Power Dissipation Per Pole | 15 W AC-1 5 W AC-3 |
Ctrl Circuit Voltage Limits | Operational 0.85...1.1 Uc AC 40...400 Hz Drop-out 0.2...0.55 Uc AC 40...400 Hz Operational 0.85...1.1 Uc DC Drop-out 0.15...0.2 Uc DC Operational 85...275 V AC 50/60 Hz Drop-out 0...60 V AC 50/60 Hz Operational 85...418 V DC Drop-out 0...45 V DC |
Heat Dissipation | 5.9…7.2 W 2.2…5.5 W |
Operating Time | 35 ms closing with LX9 coil 130 ms opening with LX9 coil 30...40 ms closing with LX4 coil 30...50 ms opening with LX4 coil 40...80 ms closing with LXE coil 6...54 ms opening with LXE coil |
Mounting Support | Plate |
Standards | EN 60947-1 JIS C8201-4-1 IEC 60947-4-1 EN 60947-4-1 IEC 60947-1 |
Product Certifications | RINA ABS CSA DNV RMRoS BV LROS (Lloyds register of shipping) UL CB |
Connections - Terminals | Power circuit lugs-ring terminals 1 0.15 in² (95 mm²) Power circuit connector 1 0.15 in² (95 mm²) Power circuit bar 2 20 x 3 mm Power circuit bolted connection Control circuit screw clamp terminals 1 0.00…0.01 in² (1…4 mm²)flexible without cable end Control circuit screw clamp terminals 2 0.00…0.01 in² (1…4 mm²)flexible with cable end Control circuit screw clamp terminals 1 0.00…0.01 in² (1…4 mm²)flexible with cable end Control circuit screw clamp terminals 2 0.00…0.00 in² (1…2.5 mm²)solid without cable end Control circuit screw clamp terminals 1 0.00…0.01 in² (1…4 mm²) Control circuit screw clamp terminals 2 0.00…0.01 in² (1…4 mm²) Control circuit screw clamp terminals 1.0 0.00…0.00 in² (0.2…2.5 mm²)flexible without cable end Control circuit screw clamp terminals 1.0 0.00…0.00 in² (0.25…2.5 mm²)flexible with cable end Control circuit screw clamp terminals 1.0 0.00…0.00 in² (0.2…2.5 mm²)solid without cable end |
Tightening Torque | Power circuit 88.51 lbf.in (10 N.m) Control circuit 10.62 lbf.in (1.2 N.m) Control circuit 5.31 lbf.in (0.6 N.m) |
Mechanical Durability | 10 Mcycles |
Inrush Power In VA | 590…855 VA, 40...400 Hz cos phi 0.9 (at 68 °F (20 °C))with LX9 coil 543…665 VA (at 68 °F (20 °C))with LX4 coil 280…310 VA, 50/60 Hz cos phi 0.5 (at 68 °F (20 °C))with LXE coil 270…320 VA (at 68 °F (20 °C))with LXE coil |
Hold-In Power Consumption Va | 6.6…8.1 VA 3.94…4.83 VA 4.5…7.0 VA 2.5…4.0 VA |
Operating Rate | 2400 cyc/h 131 °F (55 °C) |
Compatibility Code | LC1F |
IP Degree Of Protection | IP2x front face with shrouds IEC 60529 IP2x front face with shrouds VDE 0106 |
Protective Treatment | TH |
Ambient Air Temp For Op | -40…140 °F (-40…60 °C) |
Ambient Air Temp For Storage | -76…176 °F (-60…80 °C) |
Ambient Air Temp Around Device | 140…158 °F (60…70 °C) at Uc |
Operating Altitude | 9842.52 ft (3000 m) without derating |
Mechanical Robustness | Vibrations contactor open2 Gn, 5...300 Hz Vibrations contactor closed6 Gn, 5...300 Hz Shocks contactor open9 Gn for 1/2 sine wave (11 ms) Shocks contactor closed15 Gn for 1/2 sine wave (11 ms) |
Height | 6.38 in (162 mm) |
Width | 6.44 in (163.5 mm) |
Depth | 6.73 in (171 mm) |
Product Weight | 8.44 lb(US) (3.83 kg) |
Category | 22336 - CTR,F-LINE,AC,OPEN,NONREV |
Discount Schedule | I12 |
GTIN | 00785901122210 |
Nbr. Of Units In Pkg. | 1 |
Powered by
Based on 2 User Reviews
1619 Boyd St, Santa Ana, CA 92705
(714) 835-6211
(714) 972-2366