LC2D65ABBE is a 3-pole TeSys D reversing contactor from Schneider Electric for motor applications. Rated 65A AC-3 30kW@400V, it includes a 24V DC low consumption electronic coil for direct PLC control, 2NO+2NC aux contacts, mechanical interlock. LC2D65ABBE is a 3-pole TeSys D reversing contactor from Schneider Electric for motor applications up to 30kW@400V. It includes a 24V DC electronic coil for direct PLC control and 2NO+2NC built-in auxiliary contacts, NC mirror certified. Compact, DIN-rail mounting, with mechanical interlock and pre-wired reversing circuit, it procures reliability and durability. Available worldwide, it is multi-standards certified (IEC, UL, CSA, CCC, EAC, Marine) and Green Premium compliant (RoHs/Reach). Compact product, 119mm wide, for DIN-rail and panel mounting. Assembled with mechanical interlock and pre-wired reversing circuit. Clear separation between power and control circuits, easy front access to coil and auxiliary contacts connections. Equipped with an electronic 24V DC coil, low consumption, for a direct control by a PLC output 24V DC / 500mA. Provides 4 built-in auxiliary contacts 2NO + 2NC, NC contacts are mirror certified suitable to be included in the control of safety systems. High electrical durability, guaranteed for 1.6 million cycles at 65A AC-3 440V, for demanding motor switching applications. Robust design with high making and breaking capacities up to 20 In. Power connections by EverLink BTR screw terminals providing constant tightening pressure.
Add to Quote CataloguePart Number | LC2D65ABBE |
---|---|
Country of Origin | FR |
UPC | 785901765509 |
UPC11 | 78590176550 |
EAN | 3606480988196 |
Availability | N |
Lead Time | 33 |
UNSPSC | 39121529 |
HTs Code | 8536490065 |
RoHS Compliant | Yes |
Discount Schedule | I12 |
Return Indicator | Yes |
Depth | 4.72 inch |
Height | 4.80 inch |
Width | 4.69 inch |
Weight | 4.79 pound |
Range | TeSys |
---|---|
Product Name | TeSys D Green |
Product Or Component Type | Reversing contactor |
Device Short Name | LC2D |
Contactor Application | Motor control Resistive load |
Utilisation Category | AC-3 AC-1 |
Device Presentation | Preassembled with reversing power busbar |
Poles Description | 3P |
Power Pole Contact Composition | 3 NO |
Ue Rated Operational Voltage | Power circuit 690 V AC 25...400 Hz |
Ie Rated Operational Current | 80 A 140 °F (60 °C)) <= 440 V AC-1 power circuit 65 A 140 °F (60 °C)) <= 440 V AC-3 power circuit |
Motor Power kW | 18.5 kW 220...230 V AC 50 Hz 30 kW 380...400 V AC 50 Hz 37 kW 415 V AC 50 Hz 37 kW 440 V AC 50 Hz 37 kW 500 V AC 50 Hz 37 kW 660...690 V AC 50 Hz |
Motor Power Hp (Ul / Csa) | 5 hp 115 V AC 60 Hz 1 phase 10 hp 230/240 V AC 60 Hz 1 phase 20 hp 200/208 V AC 60 Hz 3 phase 20 hp 230/240 V AC 60 Hz 3 phase 40 hp 460/480 V AC 60 Hz 3 phase 50 hp 575/600 V AC 60 Hz 3 phase |
Control Circuit Type | DC DC low consumption |
Uc Control Circuit Voltage | 24 V DC |
Auxiliary Contact Composition | 1 NO + 1 NC |
Uimp Rated Imp Wstd Voltage | 6 kV IEC 60947 |
Overvoltage Category | III |
Ith Cnvtl Free Air Therm Crrt | 10 A 140 °F (60 °C) signalling circuit 80 A 140 °F (60 °C) power circuit |
Irms Rated Making Capacity | 140 A AC signalling circuit IEC 60947-5-1 250 A DC signalling circuit IEC 60947-5-1 1000 A 440 V power circuit IEC 60947 |
Rated Breaking Capacity | 1000 A 440 V power circuit IEC 60947 |
Icw Rated Short-Time Wstd Crrt | 100 A - 1 s signalling circuit 120 A - 500 ms signalling circuit 140 A - 100 ms signalling circuit 520 A 104 °F (40 °C) - 10 s power circuit 900 A 104 °F (40 °C) - 1 s power circuit 110 A 104 °F (40 °C) - 10 min power circuit 260 A 104 °F (40 °C) - 1 min power circuit |
Associated Fuse Rating | 10 A gG signalling circuit IEC 60947-5-1 125 A gG <= 690 V type 1 power circuit 125 A gG <= 690 V type 2 power circuit |
Average Impedance | 1.5 mOhm - Ith 80 A 50 Hz power circuit |
Ui Rated Insulation Voltage | Power circuit 690 V IEC 60947-4-1 Signalling circuit 690 V IEC 60947-1 |
Electrical Durability | 1.8 Mcycles 57 A AC-3 <= 440 V 0.5 Mcycles 80 A AC-1 <= 440 V |
Power Dissipation Per Pole | 9.6 W AC-1 6.3 W AC-3 |
Front Cover | With |
Interlocking Type | Mechanical |
Mounting Support | Rail Plate |
Standards | EN/IEC 60947-4-1 EN/IEC 60947-5-1 UL 60947-4-1 CSA C22.2 No 60947-4-1 |
Product Certifications | CCC CSA EAC UL KC DNV-GL LROS (Lloyds register of shipping) |
Connections - Terminals | Control circuit screw clamp terminals 1 0.00…0.01 in² (1…4 mm²)flexible without cable end Control circuit screw clamp terminals 2 0.00…0.01 in² (1…4 mm²)flexible without cable end Control circuit screw clamp terminals 1 0.00…0.01 in² (1…4 mm²)flexible with cable end Control circuit screw clamp terminals 2 0.00…0.00 in² (1…2.5 mm²)flexible with cable end Control circuit screw clamp terminals 1 0.00…0.01 in² (1…4 mm²)solid Control circuit screw clamp terminals 2 0.00…0.01 in² (1…4 mm²)solid Power circuit EverLink BTR screw connectors 1 0.00…0.05 in² (1…35 mm²)flexible without cable end Power circuit EverLink BTR screw connectors 2 0.00…0.04 in² (1…25 mm²)flexible without cable end Power circuit EverLink BTR screw connectors 1 0.00…0.05 in² (1…35 mm²)flexible with cable end Power circuit EverLink BTR screw connectors 2 0.00…0.04 in² (1…25 mm²)flexible with cable end Power circuit EverLink BTR screw connectors 1 0.00…0.05 in² (1…35 mm²)solid Power circuit EverLink BTR screw connectors 2 0.00…0.04 in² (1…25 mm²)solid |
Tightening Torque | Control circuit 15.05 lbf.in (1.7 N.m) screw clamp terminals flat Ø 6 mm Control circuit 15.05 lbf.in (1.7 N.m) screw clamp terminals Philips No 2 Power circuit 70.81 lbf.in (8 N.m) EverLink BTR screw connectors 0.04…0.05 in² (25…35 mm²) hexagonal 0.16 in (4 mm) Power circuit 44.25 lbf.in (5 N.m) EverLink BTR screw connectors 0.00…0.04 in² (1…25 mm²) hexagonal 0.16 in (4 mm) |
Operating Time | 55...65 ms closing 20...120 ms opening >= 17221) 20...80 ms opening >= 18011) |
Safety Reliability Level | B10d = 1369863 cycles contactor with nominal load EN/ISO 13849-1 B10d = 20000000 cycles contactor with mechanical load EN/ISO 13849-1 |
Mechanical Durability | 6 Mcycles |
Operating Rate | 3600 cyc/h 140 °F (60 °C) |
Coil Technology | Built-in bidirectional peak limiting |
Ctrl Circuit Voltage Limits | <= 0.1 Uc -40…158 °F (-40…70 °C) drop-out DC 0.8...1.2 Uc -40…140 °F (-40…60 °C) operational DC 1...1.2 Uc 140…158 °F (60…70 °C) operational DC |
Inrush Power In W | 11 W 68 °F (20 °C) |
Hold-In Power Consumption W | 0.5 W 68 °F (20 °C) |
Heat Dissipation | 0.5 W |
Auxiliary Contacts Type | Mechanically linked 1 NO + 1 NC IEC 60947-5-1 Mirror contact 1 NC IEC 60947-4-1 |
Signalling Circuit Frequency | 25...400 Hz |
Minimum Switching Current | 5 mA signalling circuit |
Minimum Switching Voltage | 17 V signalling circuit |
Non-Overlap Time | 1.5 ms on de-energisation between NC and NO contact 1.5 ms on energisation between NC and NO contact |
Insulation Resistance | > 10 MOhm signalling circuit |