Electrical distributor of high quality products to the LA and Orange County markets

Call Us Today To get a Quote
TeSys D IEC contactor, 18 A, 3 P, 10 HP at 480 VAC, nonreversing, 110 VAC 50/60 Hz coil, bulk packed
LC1D18F7TQ
TeSys D IEC contactor, 18 A, 3 P, 10 HP at 480 VAC, nonreversing, 110 VAC 50/60 Hz coil, bulk packed
Specifications
Part Number LC1D18F7TQ
Country of Origin FR
UPC 785901213222
UPC11 78590121322
EAN 3389110123814
Availability N
Lead Time 48
UNSPSC 39121529
ECCN EAR99
HTs Code 8536490065
Prop 65 This product can expose you to chemicals including: Antimony oxide & Antimony trioxide which is known to the State of California to cause Carcinogen harm. For more information go to www.p65warnings.ca.gov
RoHS Compliant Yes
Discount Schedule I12
Return Indicator Yes
Depth 3.39 inch
Height 3.03 inch
Width 1.77 inch
Weight 7.28 pound
Characteristics
Range Of Product TeSys D
Range TeSys
Product Or Component Type Contactor
Device Short Name LC1D
Contactor Application Resistive load Motor control
Utilisation Category AC-1 AC-3
Control Circuit Type AC 50/60 Hz
Poles Description 3P
Pole Contact Composition 3 NO
Ie Rated Operational Current 32 A 140 °F (60 °C)) <= 440 V AC AC-1 power circuit 18 A 140 °F (60 °C)) <= 440 V AC AC-3 power circuit
Motor Power kW 10 kW 500 V AC 50/60 Hz 10 kW 660...690 V AC 50/60 Hz 4 kW 220...230 V AC 50/60 Hz 7.5 kW 380...400 V AC 50/60 Hz 9 kW 415...440 V AC 50/60 Hz
Motor Power Hp 1 hp 115 V AC 50/60 Hz 1P UL 1 hp 115 V AC 50/60 Hz 1P CSA 10 hp 460/480 V AC 50/60 Hz 3P CSA 10 hp 460/480 V AC 50/60 Hz 3P UL 15 hp 575/600 V AC 50/60 Hz 3P CSA 15 hp 575/600 V AC 50/60 Hz 3P UL 5 hp 200/208 V AC 50/60 Hz 3P CSA 5 hp 200/208 V AC 50/60 Hz 3P UL 3 hp 230...240 V AC 50/60 Hz 1P CSA 3 hp 230...240 V AC 50/60 Hz 1P UL 5 hp 230...240 V AC 50/60 Hz 3P CSA 5 hp 230...240 V AC 50/60 Hz 3P UL
[Uc] Control Circuit Voltage 110 V AC 50/60 Hz
Connections - Terminals Control circuit screw clamp terminal 1 x 0.00…0.01 in² (1…4 mm²)solid without cable end Control circuit screw clamp terminal 2 x 0.00…0.01 in² (1…4 mm²)flexible without cable end Control circuit screw clamp terminal 2 x 0.00…0.01 in² (1…4 mm²)solid without cable end Control circuit spring terminal 1 x 0.00 in² (2.5 mm²)flexible without cable end Control circuit spring terminal 2 x 0.00 in² (2.5 mm²)flexible without cable end Control circuit screw clamp terminal 1 x 0.00…0.01 in² (1…4 mm²)flexible without cable end Control circuit screw clamp terminal 1 x 0.00…0.01 in² (1…4 mm²)flexible with cable end Control circuit screw clamp terminal 2 x 0.00…0.00 in² (1…2.5 mm²)flexible with cable end Power circuit ring lugs 0.31 in (8 mm)) Control circuit ring lugs 0.31 in (8 mm)) Power circuit screw clamp terminal 1 x 0.00…0.01 in² (1…6 mm²)flexible with cable end Power circuit screw clamp terminal 1 x 0.00…0.01 in² (1.5…6 mm²)flexible without cable end Power circuit screw clamp terminal 1 x 0.00…0.01 in² (1.5…6 mm²)solid without cable end Power circuit screw clamp terminal 2 x 0.00…0.01 in² (1.5…6 mm²)solid without cable end Power circuit spring terminal 1 x 0.01 in² (4 mm²)flexible without cable end Power circuit screw clamp terminal 2 x 0.00…0.01 in² (1.5…6 mm²)flexible without cable end Power circuit screw clamp terminal 2 x 0.00…0.01 in² (1…4 mm²)flexible with cable end Power circuit spring terminal 2 x 0.01 in² (4 mm²)
Quantity Per Set Set of 10
Coil Technology Without built-in bidirectional peak limiting diode suppressor
Protective Cover With
Auxiliary Contact Composition 1 NO + 1 NC
Ctrl Circuit Voltage Limits Drop-out 0.3...0.6 Uc 50/60 Hz 140 °F (60 °C)) Operational 0.8...1.1 Uc 50 Hz 140 °F (60 °C)) Operational 0.85...1.1 Uc 60 Hz 140 °F (60 °C))
Ui Rated Insulation Voltage Control circuit 600 V CSA Control circuit 600 V UL Power circuit 600 V CSA Power circuit 600 V UL Control circuit 690 V IEC 60947-4-1 Power circuit 690 V IEC 60947-4-1
Uimp Rated Imp Wstd Voltage 6 kV IEC 60947
Overvoltage Category III
Mounting Support Rail Plate
Flame Retardance V1 UL 94
Tightening Torque Control circuit 15.05 lbf.in (1.7 N.m) flat Ø 6 mm Control circuit 15.05 lbf.in (1.7 N.m) Philips No 2 Power circuit 15.05 lbf.in (1.7 N.m) flat Ø 6 mm Power circuit 15.05 lbf.in (1.7 N.m) Philips No 2
Ue Rated Operational Voltage Power circuit <= 690 V AC 25...400 Hz
Ith Cnvtl Free Air Therm Crrt 10 A 140 °F (60 °C) control circuit 32 A 140 °F (60 °C) power circuit
Irms Rated Making Capacity 140 A AC control circuit IEC 60947-5-1 300 A 440 V power circuit IEC 60947
Rated Breaking Capacity 300 kA 440 V power circuit IEC 60947
Associated Fuse Rating 10 A gG control circuit IEC 60947-5-1 35 A <= 690 V type 2 power circuit 50 A <= 690 V type 1 power circuit
Average Impedance 2.5 mOhm - Ith 32 A 50 Hz power circuit
Power Dissipation Per Pole 0.8 W AC-3 2.5 W AC-1
Inrush Power In VA 70 VA 0.75 68 °F (20 °C))
Hold-In Power Consumption Va 7 VA 50/60 Hz 0.3 68 °F (20 °C))
Operating Time 4...19 ms opening 12...22 ms closing
Safety Reliability Level B10d = 1369863 cycles contactor with nominal load EN/ISO 13849-1 B10d = 20000000 cycles contactor with mechanical load EN/ISO 13849-1
Mechanical Durability 15000000 cycles
Operating Rate 3600 cyc/h 140 °F (60 °C)
Minimum Switching Current 5 mA control circuit
Minimum Switching Voltage 17 V control circuit
Non-Overlap Time 1.5 ms on de-energisation between NC and NO contacts 1.5 ms on energisation between NC and NO contacts
Insulation Resistance > 10 MOhm control circuit
Height 3.03 in (77 mm)
Width 1.77 in (45 mm)
Depth 3.39 in (86 mm)
Product Weight 7.28 lb(US) (3.3 kg)
Standards EN/IEC 60947-4-1 CSA C22.2 No 14 EN/IEC 60947-5-1 UL 508
Product Certifications CCC GOST GL UL LROS (Lloyds register of shipping) DNV BV RINA CSA
IP Degree Of Protection IP2x IEC 60529 IP2x VDE 0106
Ambient Air Temp For Op 23…140 °F (-5…60 °C)
Documents
Royal Wholesale Electric

5.0

Powered by

Based on 2 User Reviews