TeSys D contactor, 3 poles (3NO), for motor control in railway applications up to 12A/690V AC-3 (5.5kW@400V). It provides a low consumption 24V DC coil with transient suppressor module, 1NO+1NC built-in auxiliary contacts (NC mirror certified), connection by ring-lugs screw terminals. For operating rates until 3600 cycles/hour and environments until 60°C, it procures high reliability and durability. Compact (45mm width), DIN-rail mounting or screw fixing. Multi standards certified (IEC, CCC, EAC) and compliant with the railway European standard EN 45545 R22HL3, Green Premium product (RoHS/REACh).
Add to Quote CataloguePart Number | LC1D126BLS207 |
---|---|
Country of Origin | FR |
UPC | 389118234284 |
UPC11 | 38911823428 |
EAN | 3389118234284 |
Availability | N |
Lead Time | 20 |
UNSPSC | 39121529 |
ECCN | EAR99 |
HTs Code | 8536410045 |
Prop 65 | This product can expose you to chemicals including: Antimony oxide & Antimony trioxide which is known to the State of California to cause Carcinogen harm. For more information go to www.p65warnings.ca.gov |
RoHS Compliant | Yes |
Discount Schedule | I12 |
Return Indicator | No |
Depth | 3.74 inch |
Height | 3.03 inch |
Width | 1.77 inch |
Weight | 0.72 pound |
Range | TeSys |
---|---|
Product Name | TeSys D |
Product Or Component Type | Contactor |
Device Short Name | LC1D |
Contactor Application | Motor control Resistive load |
Utilisation Category | AC-3 AC-1 |
Poles Description | 3P |
Power Pole Contact Composition | 3 NO |
Ue Rated Operational Voltage | Power circuit <= 690 V AC 25...400 Hz |
Ie Rated Operational Current | 25 A 140 °F (60 °C)) <= 440 V AC AC-1 power circuit 12 A 140 °F (60 °C)) <= 440 V AC AC-3 power circuit |
Motor Power kW | 3 kW 220/230 V AC 50 Hz AC-3) 5.5 kW 380/400 V AC 50 Hz AC-3) 5.5 kW 415 V AC 50 Hz AC-3) 5.5 kW 440 V AC 50 Hz AC-3) 7.5 kW 500 V AC 50 Hz AC-3) 7.5 kW 660/690 V AC 50 Hz AC-3) |
Uc Control Circuit Voltage | 24 V DC |
Coil Type | Low consumption |
Auxiliary Contact Composition | 1 NO + 1 NC |
Uimp Rated Imp Wstd Voltage | 6 kV IEC 60947 |
Overvoltage Category | III |
Ith Cnvtl Free Air Therm Crrt | 10 A 140 °F (60 °C) signalling circuit 25 A 140 °F (60 °C) power circuit |
Irms Rated Making Capacity | 250 A 440 V power circuit IEC 60947 140 A AC signalling circuit IEC 60947-5-1 250 A DC signalling circuit IEC 60947-5-1 |
Rated Breaking Capacity | 250 A 440 V power circuit IEC 60947 |
Icw Rated Short-Time Wstd Crrt | 100 A - 1 s signalling circuit 120 A - 500 ms signalling circuit 140 A - 100 ms signalling circuit 105 A 104 °F (40 °C) - 10 s power circuit 210 A 104 °F (40 °C) - 1 s power circuit 30 A 104 °F (40 °C) - 10 min power circuit 61 A 104 °F (40 °C) - 1 min power circuit |
Associated Fuse Rating | 10 A gG signalling circuit IEC 60947-5-1 40 A gG <= 690 V type 1 power circuit 25 A gG <= 690 V type 2 power circuit |
Average Impedance | 2.5 mOhm - Ith 25 A 50 Hz power circuit |
Ui Rated Insulation Voltage | Power circuit 690 V IEC 60947-4-1 Signalling circuit 690 V IEC 60947-1 |
Electrical Durability | 2 Mcycles 12 A AC-3 <= 440 V 0.8 Mcycles 25 A AC-1 <= 440 V |
Power Dissipation Per Pole | 1.56 W AC-1 0.36 W AC-3 |
Front Cover | With |
Mounting Support | Rail Plate |
Standards | EN/IEC 60947-4-1 EN/IEC 60947-5-1 EN 45545 R22 HL3 EN 45545 R26 HL3 DIN 5510-2 |
Product Certifications | IEC CCC EAC UA TR |
Connections - Terminals | Control circuit lugs-ring terminals 0.31 in (8 mm)) Power circuit lugs-ring terminals 0.37 in (9.5 mm)) |
Tightening Torque | Control circuit 15.05 lbf.in (1.7 N.m) lugs-ring terminals flat Ø 6 mm M3.5 Control circuit 15.05 lbf.in (1.7 N.m) lugs-ring terminals Philips No 2 M3.5 Power circuit 15.05 lbf.in (1.7 N.m) lugs-ring terminals Philips No 2 M3.5 Power circuit 15.05 lbf.in (1.7 N.m) lugs-ring terminals flat Ø 6 mm M3.5 |
Operating Time | 55...75 ms closing 16...32 ms opening |
Safety Reliability Level | B10d = 1369863 cycles contactor with nominal load EN/ISO 13849-1 B10d = 20000000 cycles contactor with mechanical load EN/ISO 13849-1 |
Mechanical Durability | 30 Mcycles |
Operating Rate | 3600 cyc/h 140 °F (60 °C) |
Coil Technology | With integral suppression device |
Ctrl Circuit Voltage Limits | 0.1...0.25 Uc -40…158 °F (-40…70 °C) drop-out DC 0.7...1.25 Uc -40…158 °F (-40…70 °C) operational DC |
Time Constant | 37 ms |
Inrush Power In W | 4 W 68 °F (20 °C) |
Hold-In Power Consumption W | 4 W 68 °F (20 °C) |
Auxiliary Contacts Type | Mechanically linked 1 NO + 1 NC IEC 60947-5-1 Mirror contact 1 NC IEC 60947-4-1 |
Signalling Circuit Frequency | 25...400 Hz |
Minimum Switching Current | 5 mA signalling circuit |
Minimum Switching Voltage | 17 V signalling circuit |
Non-Overlap Time | 1.5 ms on de-energisation between NC and NO contact 1.5 ms on energisation between NC and NO contact |
Insulation Resistance | > 10 MOhm signalling circuit |
Contact Compatibility | M5 |
Compatibility Code | LC1D |
IP Degree Of Protection | IP20 front face IEC 60529 |
Protective Treatment | TH IEC 60068-2-30 |
Powered by
Based on 2 User Reviews
1619 Boyd St, Santa Ana, CA 92705
(714) 835-6211
(714) 972-2366