Part Number | LC1D115004B7 |
---|---|
Country of Origin | CZ |
UPC | 389118075689 |
UPC11 | 38911807568 |
EAN | 3389118075689 |
Availability | N |
Lead Time | 19 |
UNSPSC | 39121529 |
ECCN | EAR99 |
HTs Code | 8536490065 |
Prop 65 | This product can expose you to chemicals including: Antimony oxide & Antimony trioxide which is known to the State of California to cause Carcinogen harm. For more information go to www.p65warnings.ca.gov |
RoHS Compliant | Yes |
Discount Schedule | I12 |
Return Indicator | No |
Depth | 5.20 inch |
Height | 6.22 inch |
Width | 5.91 inch |
Weight | 6.31 pound |
Range | TeSys |
---|---|
Product Name | TeSys D |
Product Or Component Type | Contactor |
Device Short Name | LC1D |
Contactor Application | Resistive load |
Utilisation Category | AC-1 |
Poles Description | 4P |
Power Pole Contact Composition | 4 NO |
Ue Rated Operational Voltage | Power circuit <= 1000 V AC 25...400 Hz Power circuit <= 460 V DC |
Ie Rated Operational Current | 200 A 140 °F (60 °C)) <= 440 V AC AC-1 power circuit |
Control Circuit Type | AC 50/60 Hz |
Uc Control Circuit Voltage | 24 V AC 50/60 Hz |
Uimp Rated Imp Wstd Voltage | 8 kV IEC 60947 |
Overvoltage Category | III |
Ith Cnvtl Free Air Therm Crrt | 200 A 140 °F (60 °C) power circuit |
Irms Rated Making Capacity | 1260 A 440 V power circuit IEC 60947 |
Rated Breaking Capacity | 1100 A 440 V power circuit IEC 60947 |
Icw Rated Short-Time Wstd Crrt | 250 A 104 °F (40 °C) - 10 min power circuit 550 A 104 °F (40 °C) - 1 min power circuit 950 A 104 °F (40 °C) - 10 s power circuit 1100 A 104 °F (40 °C) - 1 s power circuit |
Associated Fuse Rating | 250 A gG <= 690 V type 1 power circuit 200 A gG <= 690 V type 2 power circuit |
Average Impedance | 0.6 mOhm - Ith 200 A 50 Hz power circuit |
Ui Rated Insulation Voltage | Power circuit 600 V CSA Power circuit 600 V UL Power circuit 1000 V IEC 60947-4-1 |
Electrical Durability | 0.8 Mcycles 200 A AC-1 <= 440 V |
Power Dissipation Per Pole | 24 W AC-1 |
Front Cover | With |
Mounting Support | Rail Plate |
Standards | CSA C22.2 No 14 EN 60947-4-1 EN 60947-5-1 IEC 60947-4-1 IEC 60947-5-1 UL 508 |
Product Certifications | GOST DNV UL GL BV LROS (Lloyds register of shipping) CSA RINA CCC |
Connections - Terminals | Control circuit screw clamp terminals 2 0.00…0.00 in² (1…2.5 mm²)flexible with cable end Control circuit screw clamp terminals 1 0.00…0.00 in² (1…2.5 mm²)flexible with cable end Control circuit screw clamp terminals 1 0.00…0.00 in² (1…2.5 mm²)flexible without cable end Control circuit screw clamp terminals 2 0.00…0.00 in² (1…2.5 mm²)flexible without cable end Control circuit screw clamp terminals 1 0.00…0.00 in² (1…2.5 mm²)solid without cable end Control circuit screw clamp terminals 2 0.00…0.00 in² (1…2.5 mm²)solid without cable end Power circuit connector 1 0.02…0.19 in² (10…120 mm²)flexible without cable end Power circuit connector 2 0.02…0.08 in² (10…50 mm²)flexible without cable end Power circuit connector 1 0.02…0.19 in² (10…120 mm²)flexible with cable end Power circuit connector 2 0.02…0.08 in² (10…50 mm²)flexible with cable end Power circuit connector 1 0.02…0.19 in² (10…120 mm²)solid without cable end Power circuit connector 2 0.02…0.08 in² (10…50 mm²)solid without cable end |
Tightening Torque | Control circuit 10.62 lbf.in (1.2 N.m) screw clamp terminals flat Ø 6 mm Control circuit 10.62 lbf.in (1.2 N.m) screw clamp terminals Philips No 2 Power circuit 106.21 lbf.in (12 N.m) connector hexagonal 0.16 in (4 mm) |
Operating Time | 6...20 ms opening 20...50 ms closing |
Safety Reliability Level | B10d = 1369863 cycles contactor with nominal load EN/ISO 13849-1 B10d = 20000000 cycles contactor with mechanical load EN/ISO 13849-1 |
Mechanical Durability | 8 Mcycles |
Operating Rate | 2400 cyc/h 140 °F (60 °C) |
Coil Technology | Built-in bidirectional peak limiting diode suppressor |
Ctrl Circuit Voltage Limits | 0.3...0.5 Uc -40…158 °F (-40…70 °C) drop-out AC 50/60 Hz 0.8...1.15 Uc -40…131 °F (-40…55 °C) operational AC 50/60 Hz 1...1.15 Uc 131…158 °F (55…70 °C) operational AC 50/60 Hz |
Inrush Power In VA | 280…350 VA 60 Hz 0.8 68 °F (20 °C)) 280…350 VA 50 Hz 0.8 68 °F (20 °C)) |
Hold-In Power Consumption Va | 2…18 VA 60 Hz 0.3 68 °F (20 °C)) 2…18 VA 50 Hz 0.3 68 °F (20 °C)) |
Heat Dissipation | 3…8 W 50/60 Hz |
Contact Compatibility | M14 |
Compatibility Code | LC1D |
IP Degree Of Protection | IP20 front face IEC 60529 |
Protective Treatment | TH IEC 60068-2-30 |
Pollution Degree | 3 |
Ambient Air Temp For Op | -40…140 °F (-40…60 °C) 140…158 °F (60…70 °C) with derating |
Ambient Air Temp For Storage | -76…176 °F (-60…80 °C) |
Operating Altitude | 0...9842.52 ft (0...3000 m) |
Fire Resistance | 1562 °F (850 °C) IEC 60695-2-1 |
Flame Retardance | V1 UL 94 |
Mechanical Robustness | Vibrations contactor open2 Gn, 5...300 Hz Vibrations contactor closed4 Gn, 5...300 Hz Shocks contactor closed15 Gn for 11 ms Shocks contactor open6 Gn for 11 ms |
Height | 6.22 in (158 mm) |
Powered by
Based on 2 User Reviews
1619 Boyd St, Santa Ana, CA 92705
(714) 835-6211
(714) 972-2366