Specifications
Part Number LP1D400086UD
Country of Origin CZ
UPC 389110142211
UPC11 38911014221
EAN 3389110142211
Availability N
Lead Time 18
ECCN EAR99
HTs Code 8536490065
Prop 65 This product can expose you to chemicals including: Antimony oxide & Antimony trioxide which is known to the State of California to cause Carcinogen harm. For more information go to www.p65warnings.ca.gov
RoHS Compliant Yes
Discount Schedule I12
Return Indicator No
Depth 7.17 inch
Height 5.00 inch
Width 3.35 inch
Weight 4.87 pound
Characteristics
Range TeSys
Product Name TeSys D
Product Or Component Type Contactor
Device Short Name LP1D
Contactor Application Resistive load
Utilisation Category AC-1
Poles Description 4P
Power Pole Contact Composition 2 NO + 2 NC
Ue Rated Operational Voltage Power circuit <= 690 V AC 25...400 Hz Power circuit <= 300 V DC
Ie Rated Operational Current 60 A 140 °F (60 °C)) <= 440 V AC AC-1 power circuit
Uc Control Circuit Voltage 250 V DC
Coil Type DC standard
Uimp Rated Imp Wstd Voltage 6 kV IEC 60947
Overvoltage Category III
Ith Cnvtl Free Air Therm Crrt 60 A 140 °F (60 °C) power circuit
Irms Rated Making Capacity 800 A 440 V power circuit IEC 60947
Rated Breaking Capacity 800 A 440 V power circuit IEC 60947
Icw Rated Short-Time Wstd Crrt 72 A 104 °F (40 °C) - 10 min power circuit 165 A 104 °F (40 °C) - 1 min power circuit 320 A 104 °F (40 °C) - 10 s power circuit 720 A 104 °F (40 °C) - 1 s power circuit
Associated Fuse Rating 80 A gG <= 690 V type 1 power circuit 80 A gG <= 690 V type 2 power circuit
Average Impedance 1.5 mOhm - Ith 60 A 50 Hz power circuit
Ui Rated Insulation Voltage Power circuit 690 V IEC 60947-4-1 Power circuit 600 V CSA Power circuit 600 V UL
Electrical Durability 1.4 Mcycles 60 A AC-1 <= 440 V
Power Dissipation Per Pole 5.4 W AC-1
Front Cover Without
Mounting Support Plate Rail
Standards CSA C22.2 No 14 EN 60947-4-1 EN 60947-5-1 IEC 60947-4-1 IEC 60947-5-1 UL 508
Product Certifications BV CCC CSA DNV EAC GL LROS (Lloyds register of shipping) UL
Connections - Terminals Power circuit lugs-ring terminals 0.65 in (16.5 mm)) Control circuit lugs-ring terminals 0.31 in (8 mm))
Tightening Torque Control circuit 15.05 lbf.in (1.7 N.m) lugs-ring terminals flat Ø 6 mm M3.5 Control circuit 15.05 lbf.in (1.7 N.m) lugs-ring terminals Philips No 2 M3.5 Power circuit 53.10 lbf.in (6 N.m) lugs-ring terminals hexagonal 0.39 in (10 mm) M6
Operating Time 4...19 ms opening 12...26 ms closing
Safety Reliability Level B10d = 1369863 cycles contactor with nominal load EN/ISO 13849-1 B10d = 20000000 cycles contactor with mechanical load EN/ISO 13849-1
Mechanical Durability 10 Mcycles
Operating Rate 3600 cyc/h 140 °F (60 °C)
Coil Technology Built-in bidirectional peak limiting diode suppressor
Ctrl Circuit Voltage Limits 0.1...0.3 Uc -40…158 °F (-40…70 °C) drop-out DC 0.85...1.1 Uc -40…131 °F (-40…55 °C) operational DC 1...1.1 Uc 131…158 °F (55…70 °C) operational DC
Time Constant 75 ms
Inrush Power In W 22 W 68 °F (20 °C)
Hold-In Power Consumption W 22 W 68 °F (20 °C)
Contact Compatibility M3
Compatibility Code LP1D
IP Degree Of Protection IP20 front face IEC 60529
Protective Treatment TH IEC 60068-2-30
Pollution Degree 3
Ambient Air Temp For Op -40…140 °F (-40…60 °C) 140…158 °F (60…70 °C) with derating
Ambient Air Temp For Storage -76…176 °F (-60…80 °C)
Operating Altitude 0...9842.52 ft (0...3000 m)
Fire Resistance 1562 °F (850 °C) IEC 60695-2-1
Flame Retardance V1 UL 94
Mechanical Robustness Vibrations contactor open2 Gn, 5...300 Hz Vibrations contactor closed4 Gn, 5...300 Hz Shocks contactor open10 Gn for 11 ms Shocks contactor closed15 Gn for 11 ms
Height 5.00 in (127 mm)