Electrical distributor of high quality products to the LA and Orange County markets

Call Us Today To get a Quote
TeSys D contactor – 4P(2 NO + 2 NC) – AC-1 –
LC1D65008T6
TeSys D contactor – 4P(2 NO + 2 NC) – AC-1 –
Specifications
Part Number LC1D65008T6
Country of Origin CZ
UPC 389110073294
UPC11 38911007329
EAN 3389110073294
Availability N
Lead Time 18
ECCN EAR99
HTs Code 8536490065
Prop 65 This product can expose you to chemicals including: Antimony oxide & Antimony trioxide which is known to the State of California to cause Carcinogen harm. For more information go to www.p65warnings.ca.gov
RoHS Compliant Yes
Discount Schedule I12
Return Indicator No
Depth 4.92 inch
Height 5.00 inch
Width 3.35 inch
Weight 3.20 pound
Characteristics
Range TeSys
Product Name TeSys D
Product Or Component Type Contactor
Device Short Name LC1D
Contactor Application Resistive load
Utilisation Category AC-1
Poles Description 4P
Power Pole Contact Composition 2 NO + 2 NC
Ue Rated Operational Voltage Power circuit <= 690 V AC 25...400 Hz Power circuit <= 300 V DC
Ie Rated Operational Current 80 A 140 °F (60 °C)) <= 440 V AC AC-1 power circuit
Control Circuit Type AC 60 Hz
Uc Control Circuit Voltage 480 V AC 60 Hz
Uimp Rated Imp Wstd Voltage 6 kV IEC 60947
Overvoltage Category III
Ith Cnvtl Free Air Therm Crrt 80 A 140 °F (60 °C) power circuit
Irms Rated Making Capacity 1000 A 440 V power circuit IEC 60947
Rated Breaking Capacity 1000 A 440 V power circuit IEC 60947
Icw Rated Short-Time Wstd Crrt 520 A 104 °F (40 °C) - 10 s power circuit 900 A 104 °F (40 °C) - 1 s power circuit 110 A 104 °F (40 °C) - 10 min power circuit 260 A 104 °F (40 °C) - 1 min power circuit
Associated Fuse Rating 125 A gG <= 690 V type 1 power circuit 125 A gG <= 690 V type 2 power circuit
Average Impedance 1.5 mOhm - Ith 80 A 50 Hz power circuit
Ui Rated Insulation Voltage Power circuit 600 V CSA Power circuit 600 V UL Power circuit 690 V IEC 60947-4-1
Electrical Durability 1.4 Mcycles 80 A AC-1 <= 440 V
Power Dissipation Per Pole 9.6 W AC-1
Front Cover Without
Mounting Support Plate Rail
Standards CSA C22.2 No 14 EN 60947-4-1 EN 60947-5-1 IEC 60947-4-1 IEC 60947-5-1 UL 508
Product Certifications DNV GOST GL LROS (Lloyds register of shipping) CCC RINA UL BV CSA
Connections - Terminals Control circuit screw clamp terminals 2 0.00…0.00 in² (1…2.5 mm²)flexible with cable end Control circuit screw clamp terminals 1 0.00…0.01 in² (1…4 mm²)flexible without cable end Control circuit screw clamp terminals 2 0.00…0.01 in² (1…4 mm²)flexible without cable end Control circuit screw clamp terminals 1 0.00…0.01 in² (1…4 mm²)flexible with cable end Control circuit screw clamp terminals 1 0.00…0.01 in² (1…4 mm²)solid without cable end Control circuit screw clamp terminals 2 0.00…0.01 in² (1…4 mm²)solid without cable end Power circuit screw clamp terminals 1 0.00…0.05 in² (1…35 mm²)flexible without cable end Power circuit screw clamp terminals 2 0.00…0.04 in² (1…25 mm²)flexible without cable end Power circuit screw clamp terminals 1 0.00…0.05 in² (1…35 mm²)flexible with cable end Power circuit screw clamp terminals 2 0.00…0.04 in² (1…25 mm²)flexible with cable end Power circuit screw clamp terminals 1 0.00…0.05 in² (1…35 mm²)solid without cable end Power circuit screw clamp terminals 2 0.00…0.04 in² (1…25 mm²)solid without cable end
Tightening Torque Control circuit 15.05 lbf.in (1.7 N.m) screw clamp terminals flat Ø 6 mm Control circuit 15.05 lbf.in (1.7 N.m) screw clamp terminals Philips No 2 Power circuit 70.81 lbf.in (8 N.m) screw clamp terminals 0.04…0.05 in² (25…35 mm²) hexagonal 0.16 in (4 mm) Power circuit 44.25 lbf.in (5 N.m) screw clamp terminals 0.00…0.04 in² (1…25 mm²) hexagonal 0.16 in (4 mm)
Operating Time 4...19 ms opening 12...26 ms closing
Safety Reliability Level B10d = 1369863 cycles contactor with nominal load EN/ISO 13849-1 B10d = 20000000 cycles contactor with mechanical load EN/ISO 13849-1
Mechanical Durability 6 Mcycles
Operating Rate 3600 cyc/h 140 °F (60 °C)
Coil Technology Without built-in suppressor module
Ctrl Circuit Voltage Limits 0.85...1.1 Uc -40…140 °F (-40…60 °C) operational AC 60 Hz 0.3...0.6 Uc -40…158 °F (-40…70 °C) drop-out AC 60 Hz 1...1.1 Uc 140…158 °F (60…70 °C) operational AC 60 Hz
Inrush Power In VA 140 VA 60 Hz 0.75 68 °F (20 °C))
Hold-In Power Consumption Va 13 VA 60 Hz 0.3 68 °F (20 °C))
Heat Dissipation 4…5 W 60 Hz
Contact Compatibility M1
Compatibility Code LC1D
IP Degree Of Protection IP20 front face IEC 60529
Protective Treatment TH IEC 60068-2-30
Pollution Degree 3
Ambient Air Temp For Op -40…140 °F (-40…60 °C) 140…158 °F (60…70 °C) with derating
Ambient Air Temp For Storage -76…176 °F (-60…80 °C)
Operating Altitude 0...9842.52 ft (0...3000 m)
Fire Resistance 1562 °F (850 °C) IEC 60695-2-1
Flame Retardance V1 UL 94
Mechanical Robustness Vibrations contactor open2 Gn, 5...300 Hz Vibrations contactor closed4 Gn, 5...300 Hz Shocks contactor closed15 Gn for 11 ms Shocks contactor open10 Gn for 11 ms
Height 5.00 in (127 mm)
Documents
Royal Wholesale Electric

5.0

Powered by

Based on 2 User Reviews