TeSys D contactor – 3P(3 NO) – AC-3 –
LC1D65AP7
TeSys D contactor – 3P(3 NO) – AC-3 –

LC1D65AP7 is a compact 3-pole TeSys D contactor from Schneider Electric for motor applications. Rated 65A AC-3 30kW@400V, it includes a 230V 50/60Hz AC coil and 1NO+1NC auxiliary contacts. It can be used in safety applications. LC1D65AP7 is a 3-pole TeSys D contactor from Schneider Electric for motor applications up to 30kW@400V. It includes a 230V 50/60Hz AC coil and 1NO+1NC built-in auxiliary contacts, it can be used in safety applications thanks to its certified NC mirror contact. Compact, DIN-rail mounting, it procures high reliability and durability. Available worldwide, it is multi-standards certified (IEC, UL, CSA, CCC, EAC, Marine) and Green Premium compliant (RoHs/Reach). Compact product, 55mm wide, for DIN-rail and panel mounting. Clear separation between power and control circuits, easy front access to coil and auxiliary contacts connections. Equipped with a 230V AC coil that can be supplied at 50Hz or 60Hz. Provides 2 built-in auxiliary contacts 1NO + 1NC, NC is a certified mirror contact suitable to be included in the control of safety systems. High electrical durability, guaranteed for 1.6 million cycles at 65A AC-3 440V, for demanding motor switching applications. Robust design with high making and breaking capacities up to 20 In. Power connections by EverLink BTR screw terminals providing constant tightening pressure.

Add to Quote Catalogue
Specifications
Part Number LC1D65AP7
Country of Origin ID
UPC 785901433392
UPC11 78590143339
EAN 3389119409025
Availability N
Lead Time 66
UNSPSC 39121529
ECCN EAR99
HTs Code 8536490065
Prop 65 This product can expose you to chemicals including: Antimony oxide & Antimony trioxide which is known to the State of California to cause Carcinogen harm. For more information go to www.p65warnings.ca.gov
RoHS Compliant Yes
Discount Schedule I12
Return Indicator No
Depth 4.72 inch
Height 4.80 inch
Width 2.17 inch
Weight 1.90 pound
Characteristics
Range TeSys
Product Name TeSys D
Product Or Component Type Contactor
Device Short Name LC1D
Contactor Application Resistive load Motor control
Utilisation Category AC-3 AC-1 AC-4
Poles Description 3P
Power Pole Contact Composition 3 NO
Ue Rated Operational Voltage Power circuit <= 690 V AC 25...400 Hz Power circuit <= 300 V DC
Ie Rated Operational Current 80 A 140 °F (60 °C)) <= 440 V AC AC-1 power circuit 65 A 140 °F (60 °C)) <= 440 V AC AC-3 power circuit
Motor Power kW 11 kW 400 V AC 50/60 Hz AC-4) 18.5 kW 220...230 V AC 50/60 Hz AC-3) 30 kW 380...400 V AC 50/60 Hz AC-3) 37 kW 500 V AC 50/60 Hz AC-3) 37 kW 660...690 V AC 50/60 Hz AC-3)
Motor Power Hp (Ul / Csa) 40 hp 460/480 V AC 50/60 Hz 3 phase 5 hp 115 V AC 50/60 Hz 1 phase 10 hp 230/240 V AC 50/60 Hz 1 phase 20 hp 200/208 V AC 50/60 Hz 3 phase 20 hp 230/240 V AC 50/60 Hz 3 phase 50 hp 575/600 V AC 50/60 Hz 3 phase
Control Circuit Type AC 50/60 Hz
Uc Control Circuit Voltage 230 V AC 50/60 Hz
Auxiliary Contact Composition 1 NO + 1 NC
Uimp Rated Imp Wstd Voltage 6 kV IEC 60947
Overvoltage Category III
Ith Cnvtl Free Air Therm Crrt 10 A 140 °F (60 °C) signalling circuit 80 A 140 °F (60 °C) power circuit
Irms Rated Making Capacity 140 A AC signalling circuit IEC 60947-5-1 250 A DC signalling circuit IEC 60947-5-1 1000 A 440 V power circuit IEC 60947
Rated Breaking Capacity 1000 A 440 V power circuit IEC 60947
Icw Rated Short-Time Wstd Crrt 520 A 104 °F (40 °C) - 10 s power circuit 900 A 104 °F (40 °C) - 1 s power circuit 110 A 104 °F (40 °C) - 10 min power circuit 260 A 104 °F (40 °C) - 1 min power circuit 100 A - 1 s signalling circuit 120 A - 500 ms signalling circuit 140 A - 100 ms signalling circuit
Associated Fuse Rating 10 A gG signalling circuit IEC 60947-5-1 125 A gG <= 690 V type 1 power circuit 125 A gG <= 690 V type 2 power circuit
Average Impedance 1.5 mOhm - Ith 80 A 50 Hz power circuit
Ui Rated Insulation Voltage Power circuit 600 V CSA Power circuit 600 V UL Signalling circuit 690 V IEC 60947-1 Signalling circuit 600 V CSA Signalling circuit 600 V UL Power circuit 690 V IEC 60947-4-1
Electrical Durability 1.4 Mcycles 80 A AC-1 <= 440 V 1.45 Mcycles 65 A AC-3 <= 440 V
Power Dissipation Per Pole 9.6 W AC-1 6.3 W AC-3
Front Cover With
Mounting Support Rail Plate
Standards CSA C22.2 No 14 EN 60947-4-1 EN 60947-5-1 IEC 60947-4-1 IEC 60947-5-1 UL 508
Product Certifications UL GOST CSA CCC
Connections - Terminals Control circuit screw clamp terminals 2 0.00…0.00 in² (1…2.5 mm²)flexible with cable end Control circuit screw clamp terminals 1 0.00…0.01 in² (1…4 mm²)flexible without cable end Control circuit screw clamp terminals 2 0.00…0.01 in² (1…4 mm²)flexible without cable end Control circuit screw clamp terminals 1 0.00…0.01 in² (1…4 mm²)flexible with cable end Control circuit screw clamp terminals 1 0.00…0.01 in² (1…4 mm²)solid without cable end Control circuit screw clamp terminals 2 0.00…0.01 in² (1…4 mm²)solid without cable end Power circuit screw connection 1 0.00…0.05 in² (1…35 mm²)flexible without cable end Power circuit screw connection 2 0.00…0.04 in² (1…25 mm²)flexible without cable end Power circuit screw connection 1 0.00…0.05 in² (1…35 mm²)flexible with cable end Power circuit screw connection 2 0.00…0.04 in² (1…25 mm²)flexible with cable end Power circuit screw connection 1 0.00…0.05 in² (1…35 mm²)solid without cable end Power circuit screw connection 2 0.00…0.04 in² (1…25 mm²)solid without cable end
Tightening Torque Control circuit 15.05 lbf.in (1.7 N.m) screw clamp terminals flat Ø 6 mm Control circuit 15.05 lbf.in (1.7 N.m) screw clamp terminals Philips No 2 Power circuit 70.81 lbf.in (8 N.m) EverLink BTR screw connectors 0.04…0.05 in² (25…35 mm²) hexagonal 0.16 in (4 mm) Power circuit 44.25 lbf.in (5 N.m) EverLink BTR screw connectors 0.00…0.04 in² (1…25 mm²) hexagonal 0.16 in (4 mm)
Operating Time 4...19 ms opening 12...26 ms closing
Safety Reliability Level B10d = 1369863 cycles contactor with nominal load EN/ISO 13849-1 B10d = 20000000 cycles contactor with mechanical load EN/ISO 13849-1
Mechanical Durability 6 Mcycles
Operating Rate 3600 cyc/h 140 °F (60 °C)
Coil Technology Without built-in suppressor module
Ctrl Circuit Voltage Limits 0.3...0.6 Uc -40…158 °F (-40…70 °C) drop-out AC 50/60 Hz 0.8...1.1 Uc -40…140 °F (-40…60 °C) operational AC 50 Hz 0.85...1.1 Uc -40…140 °F (-40…60 °C) operational AC 60 Hz 1...1.1 Uc 140…158 °F (60…70 °C) operational AC 50/60 Hz
Inrush Power In VA 140 VA 60 Hz 0.75 68 °F (20 °C)) 160 VA 50 Hz 0.75 68 °F (20 °C))
Hold-In Power Consumption Va 13 VA 60 Hz 0.3 68 °F (20 °C)) 15 VA 50 Hz 0.3 68 °F (20 °C))
Heat Dissipation 4…5 W 50/60 Hz
Auxiliary Contacts Type Mechanically linked 1 NO + 1 NC IEC 60947-5-1 Mirror contact 1 NC IEC 60947-4-1
Signalling Circuit Frequency 25...400 Hz
Minimum Switching Current 5 mA signalling circuit
Minimum Switching Voltage 17 V signalling circuit
Non-Overlap Time 1.5 ms on de-energisation between NC and NO contact 1.5 ms on energisation between NC and NO contact
Insulation Resistance > 10 MOhm signalling circuit
Contact Compatibility M2
Compatibility Code LC1D
Motor Power Range 15…25 kW 200…240 V 3 phase 30…50 kW 380…440 V 3 phase 30…50 kW 480…500 V 3 phase