TeSys D contactor, 3 poles (3NO), for motor control applications up to 40A/690V AC-3 (18.5kW@400V). It provides a low consumption 100-250V AC/DC coil with electronic control, 1NO+1NC built-in auxiliary contacts (NC mirror certified), connection by ring-lugs screw terminals. For operating rates until 3600 cycles/hour and environments until 60°C, it procures high reliability and durability. Compact (55mm width), DIN-rail mounting or screw fixing. Multi standards certified (IEC, UL, CSA, CCC, EAC, Marine), Green Premium compliant (RoHS/REACh).
Add to Quote CataloguePart Number | LC1D40A6KUE |
---|---|
UPC | 606489493370 |
UPC11 | 60648949337 |
EAN | 3606489493370 |
Availability | N |
Lead Time | 40 |
UNSPSC | 39121529 |
HTs Code | 8536490065 |
RoHS Compliant | Yes |
Discount Schedule | I12 |
Depth | 4.72 inch |
Height | 4.80 inch |
Width | 2.17 inch |
Weight | 2.19 pound |
Range | TeSys |
---|---|
Product Name | TeSys D Green |
Product Or Component Type | Contactor |
Device Short Name | LC1D |
Contactor Application | Resistive load Motor control |
Utilisation Category | AC-1 AC-3 |
Poles Description | 3P |
Power Pole Contact Composition | 3 NO |
Ue Rated Operational Voltage | Power circuit <= 690 V AC 25...400 Hz |
Ie Rated Operational Current | 60 A 140 °F (60 °C)) <= 440 V AC-1 power circuit 40 A 140 °F (60 °C)) <= 440 V AC-3 power circuit |
Motor Power kW | 11 kW 220...230 V AC 50 Hz AC-3) 18.5 kW 380...400 V AC 50 Hz AC-3) 22 kW 415 V AC 50 Hz AC-3) 22 kW 440 V AC 50 Hz AC-3) 22 kW 500 V AC 50 Hz AC-3) 30 kW 660...690 V AC 50 Hz AC-3) |
Motor Power Hp (Ul / Csa) | 3 hp 115 V AC 60 Hz 1 phase 5 hp 230/240 V AC 60 Hz 1 phase 10 hp 200/208 V AC 60 Hz 3 phase 10 hp 230/240 V AC 60 Hz 3 phase 30 hp 460/480 V AC 60 Hz 3 phase 30 hp 575/600 V AC 60 Hz 3 phase |
Uc Control Circuit Voltage | 100...250 V AC 50/60 Hz 100...250 V DC |
Coil Type | AC/DC electronic |
Auxiliary Contact Composition | 1 NO + 1 NC |
Uimp Rated Imp Wstd Voltage | 6 kV IEC 60947 |
Overvoltage Category | III |
Ith Cnvtl Free Air Therm Crrt | 60 A 140 °F (60 °C) power circuit 10 A 140 °F (60 °C) signalling circuit |
Irms Rated Making Capacity | 800 A 440 V power circuit IEC 60947 140 A AC signalling circuit IEC 60947-5-1 250 A DC signalling circuit IEC 60947-5-1 |
Rated Breaking Capacity | 800 A 440 V power circuit IEC 60947 |
Icw Rated Short-Time Wstd Crrt | 72 A 104 °F (40 °C) - 10 min power circuit 165 A 104 °F (40 °C) - 1 min power circuit 320 A 104 °F (40 °C) - 10 s power circuit 720 A 104 °F (40 °C) - 1 s power circuit 100 A - 1 s signalling circuit 120 A - 500 ms signalling circuit 140 A - 100 ms signalling circuit |
Associated Fuse Rating | 80 A gG <= 690 V type 1 power circuit 80 A gG <= 690 V type 2 power circuit 10 A gG signalling circuit IEC 60947-5-1 |
Average Impedance | 1.5 mOhm - Ith 60 A 50 Hz power circuit |
Ui Rated Insulation Voltage | Power circuit 690 V IEC 60947-4-1 Signalling circuit 690 V IEC 60947-1 |
Electrical Durability | 2 Mcycles 35 A AC-3 <= 440 V 0.7 Mcycles 60 A AC-1 <= 440 V |
Power Dissipation Per Pole | 5.4 W AC-1 2.4 W AC-3 |
Front Cover | With |
Mounting Support | Plate Rail |
Standards | EN/IEC 60947-4-1 EN/IEC 60947-5-1 UL 60947-4-1 CSA C22.2 No 60947-4-1 |
Product Certifications | CCC CSA EAC UL KC DNV-GL LROS (Lloyds register of shipping) |
Connections - Terminals | Power circuit lugs-ring terminals 0.65 in (16.5 mm)) Control circuit lugs-ring terminals 0.31 in (8 mm)) |
Tightening Torque | Control circuit 15.05 lbf.in (1.7 N.m) lugs-ring terminals flat Ø 6 mm M3.5 Control circuit 15.05 lbf.in (1.7 N.m) lugs-ring terminals Philips No 2 M3.5 Power circuit 53.10 lbf.in (6 N.m) lugs-ring terminals hexagonal 0.39 in (10 mm) M6 |
Operating Time | 55...65 ms closing 20...80 ms opening |
Safety Reliability Level | B10d = 1369863 cycles contactor with nominal load EN/ISO 13849-1 B10d = 20000000 cycles contactor with mechanical load EN/ISO 13849-1 |
Mechanical Durability | 6 Mcycles |
Operating Rate | 3600 cyc/h 140 °F (60 °C) |
Coil Technology | Built-in bidirectional peak limiting |
Ctrl Circuit Voltage Limits | <= 0.1 Uc -40…158 °F (-40…70 °C) drop-out AC/DC 0.85...1.1 Uc -40…140 °F (-40…60 °C) operational AC/DC 1...1.1 Uc 140…158 °F (60…70 °C) operational AC/DC |
Inrush Power In VA | 18 VA 50/60 Hz 68 °F (20 °C)) |
Inrush Power In W | 14 W 68 °F (20 °C) |
Hold-In Power Consumption Va | 1.8 VA 68 °F (20 °C)) 50/60 Hz |
Hold-In Power Consumption W | 1.2 W 68 °F (20 °C) |
Heat Dissipation | 1.2 W 50/60 Hz |
Auxiliary Contacts Type | Mechanically linked 1 NO + 1 NC IEC 60947-5-1 Mirror contact 1 NC IEC 60947-4-1 |
Signalling Circuit Frequency | 25...400 Hz |
Minimum Switching Current | 5 mA signalling circuit |
Minimum Switching Voltage | 17 V signalling circuit |
Non-Overlap Time | 1.5 ms on de-energisation between NC and NO contact 1.5 ms on energisation between NC and NO contact |
Insulation Resistance | > 10 MOhm signalling circuit |
Compatibility Code | LC1D |
Powered by
Based on 2 User Reviews
1619 Boyd St, Santa Ana, CA 92705
(714) 835-6211
(714) 972-2366