Electrical distributor of high quality products to the LA and Orange County markets

Call Us Today To get a Quote
TeSys D contactor 3P 40A AC-3 up to 440V coil 100-250V AC/DC ring-lugs
LC1D40A6KUE
TeSys D contactor 3P 40A AC-3 up to 440V coil 100-250V AC/DC ring-lugs

TeSys D contactor, 3 poles (3NO), for motor control applications up to 40A/690V AC-3 (18.5kW@400V). It provides a low consumption 100-250V AC/DC coil with electronic control, 1NO+1NC built-in auxiliary contacts (NC mirror certified), connection by ring-lugs screw terminals. For operating rates until 3600 cycles/hour and environments until 60°C, it procures high reliability and durability. Compact (55mm width), DIN-rail mounting or screw fixing. Multi standards certified (IEC, UL, CSA, CCC, EAC, Marine), Green Premium compliant (RoHS/REACh).

Add to Quote Catalogue
Specifications
Part Number LC1D40A6KUE
UPC 606489493370
UPC11 60648949337
EAN 3606489493370
Availability N
Lead Time 40
UNSPSC 39121529
HTs Code 8536490065
RoHS Compliant Yes
Discount Schedule I12
Depth 4.72 inch
Height 4.80 inch
Width 2.17 inch
Weight 2.19 pound
Characteristics
Range TeSys
Product Name TeSys D Green
Product Or Component Type Contactor
Device Short Name LC1D
Contactor Application Resistive load Motor control
Utilisation Category AC-1 AC-3
Poles Description 3P
Power Pole Contact Composition 3 NO
Ue Rated Operational Voltage Power circuit <= 690 V AC 25...400 Hz
Ie Rated Operational Current 60 A 140 °F (60 °C)) <= 440 V AC-1 power circuit 40 A 140 °F (60 °C)) <= 440 V AC-3 power circuit
Motor Power kW 11 kW 220...230 V AC 50 Hz AC-3) 18.5 kW 380...400 V AC 50 Hz AC-3) 22 kW 415 V AC 50 Hz AC-3) 22 kW 440 V AC 50 Hz AC-3) 22 kW 500 V AC 50 Hz AC-3) 30 kW 660...690 V AC 50 Hz AC-3)
Motor Power Hp (Ul / Csa) 3 hp 115 V AC 60 Hz 1 phase 5 hp 230/240 V AC 60 Hz 1 phase 10 hp 200/208 V AC 60 Hz 3 phase 10 hp 230/240 V AC 60 Hz 3 phase 30 hp 460/480 V AC 60 Hz 3 phase 30 hp 575/600 V AC 60 Hz 3 phase
Uc Control Circuit Voltage 100...250 V AC 50/60 Hz 100...250 V DC
Coil Type AC/DC electronic
Auxiliary Contact Composition 1 NO + 1 NC
Uimp Rated Imp Wstd Voltage 6 kV IEC 60947
Overvoltage Category III
Ith Cnvtl Free Air Therm Crrt 60 A 140 °F (60 °C) power circuit 10 A 140 °F (60 °C) signalling circuit
Irms Rated Making Capacity 800 A 440 V power circuit IEC 60947 140 A AC signalling circuit IEC 60947-5-1 250 A DC signalling circuit IEC 60947-5-1
Rated Breaking Capacity 800 A 440 V power circuit IEC 60947
Icw Rated Short-Time Wstd Crrt 72 A 104 °F (40 °C) - 10 min power circuit 165 A 104 °F (40 °C) - 1 min power circuit 320 A 104 °F (40 °C) - 10 s power circuit 720 A 104 °F (40 °C) - 1 s power circuit 100 A - 1 s signalling circuit 120 A - 500 ms signalling circuit 140 A - 100 ms signalling circuit
Associated Fuse Rating 80 A gG <= 690 V type 1 power circuit 80 A gG <= 690 V type 2 power circuit 10 A gG signalling circuit IEC 60947-5-1
Average Impedance 1.5 mOhm - Ith 60 A 50 Hz power circuit
Ui Rated Insulation Voltage Power circuit 690 V IEC 60947-4-1 Signalling circuit 690 V IEC 60947-1
Electrical Durability 2 Mcycles 35 A AC-3 <= 440 V 0.7 Mcycles 60 A AC-1 <= 440 V
Power Dissipation Per Pole 5.4 W AC-1 2.4 W AC-3
Front Cover With
Mounting Support Plate Rail
Standards EN/IEC 60947-4-1 EN/IEC 60947-5-1 UL 60947-4-1 CSA C22.2 No 60947-4-1
Product Certifications CCC CSA EAC UL KC DNV-GL LROS (Lloyds register of shipping)
Connections - Terminals Power circuit lugs-ring terminals 0.65 in (16.5 mm)) Control circuit lugs-ring terminals 0.31 in (8 mm))
Tightening Torque Control circuit 15.05 lbf.in (1.7 N.m) lugs-ring terminals flat Ø 6 mm M3.5 Control circuit 15.05 lbf.in (1.7 N.m) lugs-ring terminals Philips No 2 M3.5 Power circuit 53.10 lbf.in (6 N.m) lugs-ring terminals hexagonal 0.39 in (10 mm) M6
Operating Time 55...65 ms closing 20...80 ms opening
Safety Reliability Level B10d = 1369863 cycles contactor with nominal load EN/ISO 13849-1 B10d = 20000000 cycles contactor with mechanical load EN/ISO 13849-1
Mechanical Durability 6 Mcycles
Operating Rate 3600 cyc/h 140 °F (60 °C)
Coil Technology Built-in bidirectional peak limiting
Ctrl Circuit Voltage Limits <= 0.1 Uc -40…158 °F (-40…70 °C) drop-out AC/DC 0.85...1.1 Uc -40…140 °F (-40…60 °C) operational AC/DC 1...1.1 Uc 140…158 °F (60…70 °C) operational AC/DC
Inrush Power In VA 18 VA 50/60 Hz 68 °F (20 °C))
Inrush Power In W 14 W 68 °F (20 °C)
Hold-In Power Consumption Va 1.8 VA 68 °F (20 °C)) 50/60 Hz
Hold-In Power Consumption W 1.2 W 68 °F (20 °C)
Heat Dissipation 1.2 W 50/60 Hz
Auxiliary Contacts Type Mechanically linked 1 NO + 1 NC IEC 60947-5-1 Mirror contact 1 NC IEC 60947-4-1
Signalling Circuit Frequency 25...400 Hz
Minimum Switching Current 5 mA signalling circuit
Minimum Switching Voltage 17 V signalling circuit
Non-Overlap Time 1.5 ms on de-energisation between NC and NO contact 1.5 ms on energisation between NC and NO contact
Insulation Resistance > 10 MOhm signalling circuit
Compatibility Code LC1D
Documents
Royal Wholesale Electric

5.0

Powered by

Based on 2 User Reviews