LC1D25BNE is a compact 3-pole TeSys D contactor from Schneider Electric for motor applications. Rated 25A AC-3 11kW@400V, it includes a 24-60V AC/DC low consumption electronic coil and 1NO+1NC aux contacts. It can be used in safety applications. LC1D25BNE is a 3-pole TeSys D contactor from Schneider Electric for motor applications up to 11kW@400V. It includes a 24-60V AC/DC low consumption electronic coil and 1NO+1NC built-in auxiliary contacts, it can be used in safety applications thanks to its certified NC mirror contact. Compact, DIN-rail mounting, it procures high reliability and durability. Available worldwide, it is multi-standards certified (IEC, UL, CSA, CCC, EAC, Marine) and Green Premium compliant (RoHs/Reach). Compact product, 45mm wide, for DIN-rail and panel mounting. Clear separation between power and control circuits, easy front access to coil and auxiliary contacts connections. Equipped with an electronic coil, wide band voltage 24-60V, AC/DC compatible, low consumption. Provides 2 built-in auxiliary contacts 1NO + 1NC, NC is a certified mirror contact suitable to be included in the control of safety systems. High electrical durability, guaranteed for 2 million cycles at 25A AC-3 440V, for demanding motor switching applications. Robust design with high making and breaking capacities up to 20 In. Connection by screw clamp terminals.
Add to Quote CataloguePart Number | LC1D25BNE |
---|---|
Country of Origin | FR |
UPC | 785901764946 |
UPC11 | 78590176494 |
EAN | 3606480987724 |
Availability | N |
Lead Time | 33 |
UNSPSC | 39121529 |
HTs Code | 8536490080 |
RoHS Compliant | Yes |
Discount Schedule | I12 |
Return Indicator | Yes |
Depth | 3.62 inch |
Height | 3.35 inch |
Width | 1.77 inch |
Weight | 0.95 pound |
Range | TeSys |
---|---|
Product Name | TeSys D Green |
Product Or Component Type | Contactor |
Device Short Name | LC1D |
Contactor Application | Resistive load Motor control |
Utilisation Category | AC-3 AC-1 |
Poles Description | 3P |
Power Pole Contact Composition | 3 NO |
Ue Rated Operational Voltage | Power circuit <= 690 V AC 25...400 Hz |
Ie Rated Operational Current | 25 A 140 °F (60 °C)) <= 440 V AC-3 power circuit 40 A 140 °F (60 °C)) <= 440 V AC-1 power circuit |
Motor Power kW | 5.5 kW 220...230 V AC 50 Hz AC-3) 11 kW 380...400 V AC 50 Hz AC-3) 11 kW 415 V AC 50 Hz AC-3) 11 kW 440 V AC 50 Hz AC-3) 15 kW 500 V AC 50 Hz AC-3) 15 kW 660...690 V AC 50 Hz AC-3) |
Motor Power Hp (Ul / Csa) | 2 hp 115 V AC 60 Hz 1 phase 3 hp 230/240 V AC 60 Hz 1 phase 7.5 hp 200/208 V AC 60 Hz 3 phase 7.5 hp 230/240 V AC 60 Hz 3 phase 15 hp 460/480 V AC 60 Hz 3 phase 20 hp 575/600 V AC 60 Hz 3 phase |
Uc Control Circuit Voltage | 24...60 V AC 50/60 Hz 24...60 V DC |
Coil Type | AC/DC electronic |
Auxiliary Contact Composition | 1 NO + 1 NC |
Uimp Rated Imp Wstd Voltage | 6 kV IEC 60947 |
Overvoltage Category | III |
Ith Cnvtl Free Air Therm Crrt | 10 A 140 °F (60 °C) signalling circuit 40 A 140 °F (60 °C) power circuit |
Irms Rated Making Capacity | 140 A AC signalling circuit IEC 60947-5-1 250 A DC signalling circuit IEC 60947-5-1 450 A 440 V power circuit IEC 60947 |
Rated Breaking Capacity | 450 A 440 V power circuit IEC 60947 |
Icw Rated Short-Time Wstd Crrt | 100 A - 1 s signalling circuit 120 A - 500 ms signalling circuit 140 A - 100 ms signalling circuit 50 A 104 °F (40 °C) - 10 min power circuit 120 A 104 °F (40 °C) - 1 min power circuit 240 A 104 °F (40 °C) - 10 s power circuit 380 A 104 °F (40 °C) - 1 s power circuit |
Associated Fuse Rating | 10 A gG signalling circuit IEC 60947-5-1 63 A gG <= 690 V type 1 power circuit 40 A gG <= 690 V type 2 power circuit |
Average Impedance | 2 mOhm - Ith 40 A 50 Hz power circuit |
Ui Rated Insulation Voltage | Power circuit 690 V IEC 60947-4-1 Signalling circuit 690 V IEC 60947-1 |
Electrical Durability | 2 Mcycles 21 A AC-3 <= 440 V 0.9 Mcycles 40 A AC-1 <= 440 V |
Power Dissipation Per Pole | 3.2 W AC-1 1.25 W AC-3 |
Front Cover | With |
Mounting Support | Plate Rail |
Standards | EN/IEC 60947-4-1 EN/IEC 60947-5-1 UL 60947-4-1 CSA C22.2 No 60947-4-1 |
Product Certifications | CCC CSA EAC UL KC DNV-GL LROS (Lloyds register of shipping) |
Connections - Terminals | Control circuit screw clamp terminals 1 0.00…0.01 in² (1…4 mm²)flexible without cable end Control circuit screw clamp terminals 2 0.00…0.01 in² (1…4 mm²)flexible without cable end Control circuit screw clamp terminals 1 0.00…0.01 in² (1…4 mm²)flexible with cable end Control circuit screw clamp terminals 2 0.00…0.00 in² (1…2.5 mm²)flexible with cable end Control circuit screw clamp terminals 1 0.00…0.01 in² (1…4 mm²)solid Control circuit screw clamp terminals 2 0.00…0.01 in² (1…4 mm²)solid Power circuit screw clamp terminals 1 0.00…0.02 in² (2.5…10 mm²)flexible without cable end Power circuit screw clamp terminals 2 0.00…0.02 in² (2.5…10 mm²)flexible without cable end Power circuit screw clamp terminals 1 0.00…0.02 in² (1…10 mm²)flexible with cable end Power circuit screw clamp terminals 2 0.00…0.01 in² (1.5…6 mm²)flexible with cable end Power circuit screw clamp terminals 1 0.00…0.02 in² (1.5…10 mm²)solid Power circuit screw clamp terminals 2 0.00…0.02 in² (2.5…10 mm²)solid |
Tightening Torque | Control circuit 15.05 lbf.in (1.7 N.m) screw clamp terminals flat Ø 6 mm Control circuit 15.05 lbf.in (1.7 N.m) screw clamp terminals Philips No 2 Power circuit 22.13 lbf.in (2.5 N.m) screw clamp terminals flat Ø 6 mm Power circuit 22.13 lbf.in (2.5 N.m) screw clamp terminals Philips No 2 |
Operating Time | 45...55 ms closing 20...90 ms opening |
Safety Reliability Level | B10d = 1369863 cycles contactor with nominal load EN/ISO 13849-1 B10d = 20000000 cycles contactor with mechanical load EN/ISO 13849-1 |
Mechanical Durability | 15 Mcycles |
Operating Rate | 3600 cyc/h 140 °F (60 °C) |
Coil Technology | Built-in bidirectional peak limiting |
Ctrl Circuit Voltage Limits | <= 0.1 Uc -40…158 °F (-40…70 °C) drop-out AC/DC 0.85...1.1 Uc -40…140 °F (-40…60 °C) operational AC 0.8...1.1 Uc -40…140 °F (-40…60 °C) operational DC 1...1.1 Uc 140…158 °F (60…70 °C) operational AC/DC |
Inrush Power In VA | 15 VA 50/60 Hz 68 °F (20 °C)) |
Inrush Power In W | 14 W 68 °F (20 °C) |
Hold-In Power Consumption Va | 0.9 VA 68 °F (20 °C)) 50/60 Hz |
Hold-In Power Consumption W | 0.6 W 68 °F (20 °C) |
Heat Dissipation | 0.6 W 50/60 Hz |
Auxiliary Contacts Type | Mechanically linked 1 NO + 1 NC IEC 60947-5-1 Mirror contact 1 NC IEC 60947-4-1 |
Signalling Circuit Frequency | 25...400 Hz |
Minimum Switching Current | 5 mA signalling circuit |
Minimum Switching Voltage | 17 V signalling circuit |
Non-Overlap Time | 1.5 ms on de-energisation between NC and NO contact 1.5 ms on energisation between NC and NO contact |
Insulation Resistance | > 10 MOhm signalling circuit |
Compatibility Code | LC1D |