Electrical distributor of high quality products to the LA and Orange County markets

Call Us Today To get a Quote
TeSys D changeover contactor – 4P(4 NO) – AC-1 –
LC2D80004M5
TeSys D changeover contactor – 4P(4 NO) – AC-1 –
Specifications
Part Number LC2D80004M5
Country of Origin CZ
UPC 389110086645
UPC11 38911008664
EAN 3389110086645
Availability N
Lead Time 19
UNSPSC 39121529
ECCN EAR99
HTs Code 8536490065
Prop 65 This product can expose you to chemicals including: Antimony oxide & Antimony trioxide which is known to the State of California to cause Carcinogen harm. For more information go to www.p65warnings.ca.gov
RoHS Compliant Yes
Discount Schedule I12
Return Indicator No
Depth 6.22 inch
Height 5.00 inch
Width 8.15 inch
Weight 7.05 pound
Characteristics
Range TeSys
Product Name TeSys D
Product Or Component Type Changeover contactor
Device Short Name LC2D
Contactor Application Resistive load
Utilisation Category AC-1
Device Presentation Preassembled, with prewired power connections
Poles Description 4P
Power Pole Contact Composition 4 NO
Ue Rated Operational Voltage Power circuit <= 1000 V AC 25...400 Hz Power circuit <= 300 V DC
Ie Rated Operational Current 125 A 140 °F (60 °C)) <= 440 V AC AC-1 power circuit
Control Circuit Type AC 50 Hz
Uc Control Circuit Voltage 220 V AC 50 Hz
Uimp Rated Imp Wstd Voltage 8 kV IEC 60947
Overvoltage Category III
Ith Cnvtl Free Air Therm Crrt 125 A 140 °F (60 °C) power circuit
Irms Rated Making Capacity 1100 A 440 V power circuit IEC 60947
Rated Breaking Capacity 1100 A 440 V power circuit IEC 60947
Icw Rated Short-Time Wstd Crrt 135 A 104 °F (40 °C) - 10 min power circuit 320 A 104 °F (40 °C) - 1 min power circuit 640 A 104 °F (40 °C) - 10 s power circuit 990 A 104 °F (40 °C) - 1 s power circuit
Associated Fuse Rating 200 A gG <= 690 V type 1 power circuit 160 A gG <= 690 V type 2 power circuit
Average Impedance 0.8 mOhm - Ith 125 A 50 Hz power circuit
Ui Rated Insulation Voltage Power circuit 600 V CSA Power circuit 600 V UL Power circuit 1000 V IEC 60947-4-1
Electrical Durability 0.8 Mcycles 125 A AC-1 <= 440 V
Power Dissipation Per Pole 12.5 W AC-1
Front Cover Without
Interlocking Type Mechanical
Mounting Support Plate Rail
Standards CSA C22.2 No 14 EN 60947-4-1 EN 60947-5-1 IEC 60947-4-1 IEC 60947-5-1 UL 508
Product Certifications UL CSA BV RINA GOST DNV LROS (Lloyds register of shipping) CCC GL
Connections - Terminals Control circuit screw clamp terminals 1 0.00…0.01 in² (1…4 mm²)flexible without cable end Control circuit screw clamp terminals 2 0.00…0.01 in² (1…4 mm²)flexible without cable end Control circuit screw clamp terminals 2 0.00…0.00 in² (1…2.5 mm²)flexible with cable end Control circuit screw clamp terminals 1 0.00…0.01 in² (1…4 mm²)solid Control circuit screw clamp terminals 2 0.00…0.01 in² (1…4 mm²)solid Control circuit screw clamp terminals 1 0.00…0.00 in² (1…2.5 mm²)flexible with cable end Power circuit connector 1 0.01…0.08 in² (4…50 mm²)flexible without cable end Power circuit connector 2 0.01…0.04 in² (4…25 mm²)flexible without cable end Power circuit connector 1 0.01…0.08 in² (4…50 mm²)flexible with cable end Power circuit connector 2 0.01…0.02 in² (4…16 mm²)flexible with cable end Power circuit connector 1 0.01…0.08 in² (4…50 mm²)solid Power circuit connector 2 0.01…0.04 in² (4…25 mm²)solid
Tightening Torque Control circuit 10.62 lbf.in (1.2 N.m) screw clamp terminals flat Ø 6 mm Control circuit 10.62 lbf.in (1.2 N.m) screw clamp terminals Philips No 2 Power circuit 106.21 lbf.in (12 N.m) connector flat Ø 6 to Ø 8 mm Power circuit 106.21 lbf.in (12 N.m) connector hexagonal 0.16 in (4 mm)
Operating Time 20...35 ms closing 6...20 ms opening
Safety Reliability Level B10d = 1369863 cycles contactor with nominal load EN/ISO 13849-1 B10d = 20000000 cycles contactor with mechanical load EN/ISO 13849-1
Mechanical Durability 10 Mcycles
Operating Rate 3600 cyc/h 140 °F (60 °C)
Coil Technology Without built-in suppressor module
Ctrl Circuit Voltage Limits 0.3...0.6 Uc -40…158 °F (-40…70 °C) drop-out AC 50 Hz 0.85...1.1 Uc -40…131 °F (-40…55 °C) operational AC 50 Hz 1...1.1 Uc 131…158 °F (55…70 °C) operational AC 50 Hz
Inrush Power In VA 200 VA 50 Hz 0.75 68 °F (20 °C))
Hold-In Power Consumption Va 20 VA 50 Hz 0.3 68 °F (20 °C))
Heat Dissipation 6…10 W 50 Hz
Contact Compatibility M1
Compatibility Code LC2D
IP Degree Of Protection IP20 front face IEC 60529
Protective Treatment TH IEC 60068-2-30
Pollution Degree 3
Ambient Air Temp For Op -40…140 °F (-40…60 °C) 140…158 °F (60…70 °C) with derating
Ambient Air Temp For Storage -76…176 °F (-60…80 °C)
Operating Altitude 0...9842.52 ft (0...3000 m)
Fire Resistance 1562 °F (850 °C) IEC 60695-2-1
Flame Retardance V1 UL 94
Documents
Royal Wholesale Electric

5.0

Powered by

Based on 2 User Reviews