Electrical distributor of high quality products to the LA and Orange County markets

Call Us Today To get a Quote
Symmetra PX 125kW Scalable to 500kW with Maintenance Bypass and Distribution, No Batteries
SY125K500DR-PDNB
Symmetra PX 125kW Scalable to 500kW with Maintenance Bypass and Distribution, No Batteries
Specifications
Part Number SY125K500DR-PDNB
Depth 42.13 inch
Height 78.39 inch
Width 86.61 inch
Weight 3304.73 pound
Characteristics
Presentation A high-performance, 3-phase, modular, scalable, power protection solution with industry-leading efficiency, capacity, and performance for medium to large data centers and mission critical environments.
Lead Time Usually Ships within 6 Weeks
Provided Equipment Assembly service Installation guide Network Management Card Start-Up Service User Manual
Bypass Voltage Tolerance +/-10% settable from +/-4/6/8 and 10%
Colour Black
Depth 42.13 in (107 cm)
Height 78.39 in (199.1 cm)
Product Weight 3304.73 lb(US) (1499 kg)
Width 86.61 in (220 cm)
Network Frequency 40 - 70 Hz auto-sensing
Number Of Input Connectors 1 Hard Wire 4-wire (3PH + G) 1 Hard Wire 5-wire (3PH + N + G)
Input Voltage Limits 408...552 V 480 V
Inputvolt_Other 415 V
Max Short Time Withstd Current 50 kA
Input Harmonic Distortion Less than 5% for full load
Input Protection Type 3-pole breaker
Input Voltage 3 phase 3 phase
Rated Power In W 125000 W
Max Configurable Power In W 500000 W
Harmonic Distortion Less than 2%
Output Frequency 50 Hz sync to mains 60 Hz +/- 0.1 % for 60 Hz nominal not synced 50 Hz +/- 0.1 % for 50 Hz nominal not synced 60 Hz sync to mains
Outputvolt_Other 415 V
Ups Type Double Conversion Online
Wave Type Sine wave
Output Connector Type Hard Wire 4-wire (3PH + G) 1
Output Voltage Tolerance +/-1% static and +/- 5% at 100% load step
Output Harmonic Distortion < 2% linear load and < 3% non-linear load
Output Overload Operation 10 minutes @ 125% and 60 seconds @ 150%
Bypass Type Built-in Maintenance Bypass Built-in Static Bypass
Output Voltage 480 V 3 phase 400 V 3 phase
Product Certifications CUL Listed UL Listed
Standards CSA C22.2 No.107.3-05 EN/IEC 62040-1-1 EN/IEC 62040-2 EN/IEC 62040-3 OSHPD UL 1778 UL 60950-1
Ambient Air Temp For Op 32…104 °F (0…40 °C)
Relative Humidity 0…95 %
Operating Altitude 0...3333 ft
Ambient Air Temp For Storage -22…158 °F (-30…70 °C)
Storage Altitude 0…50000 ft (0.00…15240.00 m)
Acoustic Level 54 dBA
Heat Dissipation 19427 Btu/h
Nema Degree Of Protection NEMA 1
IP Degree Of Protection IP20
Free Slots 1
Preinstalled Device Network management card 2 with environmental monitoring, out of band access and Modbus
Control Panel Touch Screen LCD User Interface
Emergency Power Off Optional
REACh Free Of SVHC Yes
EU RoHs Directive Not compliant
Optimized Energy Efficiency Energy efficient product
Documents
Royal Wholesale Electric

5.0

Powered by

Based on 2 User Reviews