Electrical distributor of high quality products to the LA and Orange County markets

Call Us Today To get a Quote
SIL interface module, TeSys island
TPRSM001
SIL interface module, TeSys island

TeSys island SIL interface module, 2 inputs, 1 output. Connected to a TPRBC bus coupler, it allows integration into safety related systems conforming to ISO 13849-1. It is used in connection to one or several SIL motor starter TPRSS. Two isolated switching inputs with common point, 0-24V DC. One relay type output, 1NO, instantaneous opening, potential free. Mounting on DIN rail together with the other modules of the TeSys island configuration. Multi standards certified (IEC, UL, CSA, CCC, EAC), Green Premium compliant (RoHS/REACh).

Add to Quote Catalogue
Specifications
Part Number TPRSM001
Country of Origin ID
UPC 606489832872
UPC11 60648983287
EAN 3606489832872
Availability N
Lead Time 16
ECCN EAR99
HTs Code 8538908180
RoHS Compliant Yes
Discount Schedule I12
Return Indicator Yes
Depth 4.49 inch
Height 4.65 inch
Width 0.98 inch
Weight 0.35 pound
Characteristics
Range TeSys
Product Name TeSys island
Device Short Name TPRSM
Product Or Component Type SIL interface module
Device Presentation Implementation of a safe stop function for SIL motor starters TPRSS Safe stop operable for safety-related system conforming to ISO 13849-1 Operational only when connected to a bus coupler TPRBC
Function Of Module Safe stop with 1NC or 2NC contacts monitoring
Product Compatibility TPRBC bus coupler TPRSS SIL motor starter
Ue Rated Operational Voltage Input/output circuit 24 V DC
Ui Rated Insulation Voltage Input/output circuit 50 V
Uimp Rated Imp Wstd Voltage 2 kV input/output circuit IEC 60947-1
Overvoltage Category III
Input Type Isolated switching input safe stop
Input Protection Type Internal, electronic
Input Voltage 15...28.8 V DC state 1 0...5 V DC state 0
Output Type Relay instantaneous opening, 1 NO, potential free
Output Thermal Current 8 A relay output
Protection Type External fuse, 8 A gG relay output
Local Signalling DS (device status) 1 LED green/red) SS (safe stop status) 1 LED green/red)
Us Rated Supply Voltage 24 V DC supplied by the bus coupler
Current Consumption 10 mA
Power Dissipation In W 0.7 W maximum
Safety Function Safe stop IEC 60204-1 Safe stop IEC 60204-1
Safety Integrity Level SIL 2 IEC 61508 SILCL 2 IEC 62061 PL = d ISO 13849-1
Standards UL 60947-5-1 IEC 60947-5-1
Product Certifications EAC (pending) UL CSA
Mounting Mode Horizontal and vertical 35 mm symmetrical rail)
Connections - Terminals Control circuit removable spring terminal block 5 0.00…0.00 in² (0.2…2.5 mm²) AWG 24...AWG 14)rigid Control circuit removable spring terminal block 5 0.00…0.00 in² (0.2…2.5 mm²) AWG 24...AWG 14)flexible without cable end Control circuit removable spring terminal block 5 0.00…0.00 in² (0.25…2.5 mm²) AWG 22...AWG 14)flexible with cable end
Width 0.98 in (25 mm)
Height 4.65 in (118 mm)
Depth 4.49 in (114 mm)
Product Weight 0.35 lb(US) (0.159 kg)
Ambient Air Temp For Storage -13…158 °F (-25…70 °C)
Ambient Air Temp For Op 14…140 °F (-10…60 °C)
Relative Humidity 5…95 %
Operating Altitude 0...6561.68 ft (0...2000 m) without derating
IP Degree Of Protection IP20
Pollution Degree 2
Protective Treatment TC
Fire Resistance 1760 °F (960 °C) UL 94
Shock Resistance 15 gn 11 ms) IEC 60068-2-27
Vibration Resistance 1.5 mm peak to peak 3…13 Hz) IEC 60068-2-6 1 gn 13…200 Hz) IEC 60068-2-6
Electromagnetic Compatibility Electrostatic discharge, level 3 8 kV air, 6 kV contact)EN/IEC 61000-4-2) Radiated RF fields, level 3 10 V/m)EN/IEC 61000-4-3) Fast transients immunity test, level 3 2 kV)EN/IEC 61000-4-4) Surge immunity test, level 3 2 kV)EN/IEC 61000-4-5)
Category 22353 - TESYS ISLAND AUXILIARY DEVICES
Discount Schedule I12
GTIN 03606489832872
Nbr. Of Units In Pkg. 1
Country Of Origin ID
EU RoHs Directive Compliant
Mercury Free Yes
WEEE The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.