TeSys island SIL interface module, 2 inputs, 1 output. Connected to a TPRBC bus coupler, it allows integration into safety related systems conforming to ISO 13849-1. It is used in connection to one or several SIL motor starter TPRSS. Two isolated switching inputs with common point, 0-24V DC. One relay type output, 1NO, instantaneous opening, potential free. Mounting on DIN rail together with the other modules of the TeSys island configuration. Multi standards certified (IEC, UL, CSA, CCC, EAC), Green Premium compliant (RoHS/REACh).
Add to Quote CataloguePart Number | TPRSM001 |
---|---|
Country of Origin | ID |
UPC | 606489832872 |
UPC11 | 60648983287 |
EAN | 3606489832872 |
Availability | N |
Lead Time | 16 |
ECCN | EAR99 |
HTs Code | 8538908180 |
RoHS Compliant | Yes |
Discount Schedule | I12 |
Return Indicator | Yes |
Depth | 4.49 inch |
Height | 4.65 inch |
Width | 0.98 inch |
Weight | 0.35 pound |
Range | TeSys |
---|---|
Product Name | TeSys island |
Device Short Name | TPRSM |
Product Or Component Type | SIL interface module |
Device Presentation | Implementation of a safe stop function for SIL motor starters TPRSS Safe stop operable for safety-related system conforming to ISO 13849-1 Operational only when connected to a bus coupler TPRBC |
Function Of Module | Safe stop with 1NC or 2NC contacts monitoring |
Product Compatibility | TPRBC bus coupler TPRSS SIL motor starter |
Ue Rated Operational Voltage | Input/output circuit 24 V DC |
Ui Rated Insulation Voltage | Input/output circuit 50 V |
Uimp Rated Imp Wstd Voltage | 2 kV input/output circuit IEC 60947-1 |
Overvoltage Category | III |
Input Type | Isolated switching input safe stop |
Input Protection Type | Internal, electronic |
Input Voltage | 15...28.8 V DC state 1 0...5 V DC state 0 |
Output Type | Relay instantaneous opening, 1 NO, potential free |
Output Thermal Current | 8 A relay output |
Protection Type | External fuse, 8 A gG relay output |
Local Signalling | DS (device status) 1 LED green/red) SS (safe stop status) 1 LED green/red) |
Us Rated Supply Voltage | 24 V DC supplied by the bus coupler |
Current Consumption | 10 mA |
Power Dissipation In W | 0.7 W maximum |
Safety Function | Safe stop IEC 60204-1 Safe stop IEC 60204-1 |
Safety Integrity Level | SIL 2 IEC 61508 SILCL 2 IEC 62061 PL = d ISO 13849-1 |
Standards | UL 60947-5-1 IEC 60947-5-1 |
Product Certifications | EAC (pending) UL CSA |
Mounting Mode | Horizontal and vertical 35 mm symmetrical rail) |
Connections - Terminals | Control circuit removable spring terminal block 5 0.00…0.00 in² (0.2…2.5 mm²) AWG 24...AWG 14)rigid Control circuit removable spring terminal block 5 0.00…0.00 in² (0.2…2.5 mm²) AWG 24...AWG 14)flexible without cable end Control circuit removable spring terminal block 5 0.00…0.00 in² (0.25…2.5 mm²) AWG 22...AWG 14)flexible with cable end |
Width | 0.98 in (25 mm) |
Height | 4.65 in (118 mm) |
Depth | 4.49 in (114 mm) |
Product Weight | 0.35 lb(US) (0.159 kg) |
Ambient Air Temp For Storage | -13…158 °F (-25…70 °C) |
Ambient Air Temp For Op | 14…140 °F (-10…60 °C) |
Relative Humidity | 5…95 % |
Operating Altitude | 0...6561.68 ft (0...2000 m) without derating |
IP Degree Of Protection | IP20 |
Pollution Degree | 2 |
Protective Treatment | TC |
Fire Resistance | 1760 °F (960 °C) UL 94 |
Shock Resistance | 15 gn 11 ms) IEC 60068-2-27 |
Vibration Resistance | 1.5 mm peak to peak 3…13 Hz) IEC 60068-2-6 1 gn 13…200 Hz) IEC 60068-2-6 |
Electromagnetic Compatibility | Electrostatic discharge, level 3 8 kV air, 6 kV contact)EN/IEC 61000-4-2) Radiated RF fields, level 3 10 V/m)EN/IEC 61000-4-3) Fast transients immunity test, level 3 2 kV)EN/IEC 61000-4-4) Surge immunity test, level 3 2 kV)EN/IEC 61000-4-5) |
Category | 22353 - TESYS ISLAND AUXILIARY DEVICES |
Discount Schedule | I12 |
GTIN | 03606489832872 |
Nbr. Of Units In Pkg. | 1 |
Country Of Origin | ID |
EU RoHs Directive | Compliant |
Mercury Free | Yes |
WEEE | The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins. |