This XCSTR Safety Limit Switch has a 30 mm stainless steel spindle, a double insulated plastic enclosure and 2 x Pg 11 cable gland entries. It has 1 normally open and 2 normally closed break-before-make (slow break) contacts. Its B10D reliability data is 5 000 000. Its IP67 degree of protection makes it ideal for heavy duty use in harsh conditions. It also complies with EN/ISO 14119, EN/IEC 60204-1, EN/IEC 60947-5-1, EN/IEC 60947-5-4, UL 508, CSA C22.2 No 14 standards. When associated and correctly connected to an appropriate safety control unit, it conforms to Category 4, performance level PL e, SIL 3 as described in EN/ISO 13849-1, EN/IEC 61508.
Brand: Telemecanique
Add to Quote CataloguePart Number | XCSTR751 |
---|---|
Country of Origin | FR |
UPC | 389110177244 |
UPC11 | 38911017724 |
EAN | 3389110177244 |
Availability | N |
Lead Time | 20 |
ECCN | EAR99 |
HTs Code | 8536509065 |
Prop 65 | This product can expose you to chemicals including: Di-isodecyl phthalate (DIDP) and Diisononyl phthalate (DINP) which is known to the State of California to cause Carcinogen and Reproductive harm. For more information go to www.p65warnings.ca.gov |
RoHS Compliant | Yes |
Discount Schedule | T |
Return Indicator | No |
Depth | 2.36 inch |
Height | 4.61 inch |
Width | 2.05 inch |
Weight | 0.34 pound |
Range Of Product | Preventa Safety detection |
---|---|
Product Or Component Type | Guard switch |
Component Name | XCSTR |
Material | Plastic |
Head Type | Turret head rotary axis |
Insulation | Double insulated |
Type Of Operator | Spindle 30 mm |
Electrical Connection | Terminal |
Contacts Type And Composition | 1 NC + 1 NC + 1 NO |
Contact Operation | Slow-break, break before make |
Clamping Connection Capacity | 1 x 0.34...2 x 0.75 mm² with or without cable end |
Cable Entry | 2 entries tapped Pg 11 |
Number Of Poles | 3 |
Cable Outer Diameter | 0.28…0.39 in (7…10 mm) |
Positive Opening | With NC contact |
Tripping Angle | 5 ° |
Mechanical Durability | 1000000 cycles |
Minimum Torque For Tripping | 0.89 lbf.in (0.1 N.m) |
Positive Opening Min Torque | 3.98 lbf.in (0.45 N.m) |
Minimum Actuation Speed | 0.33 ft/s (0.1 m/s) |
Contact Code Designation | B300, AC-15 (Ue = 120 V, Ie = 6 A)EN/IEC 60947-5-1 B300, AC-15 (Ue = 240 V, Ie = 3 A)EN/IEC 60947-5-1 Q300, DC-13 (Ue = 125 V, Ie = 0.2 A)EN/IEC 60947-5-1 R300, DC-13 (Ue = 250 V, Ie = 0.1 A)EN/IEC 60947-5-1 |
Ithe Cnvtl Enclosed Therm Crrt | 6 A |
Ui Rated Insulation Voltage | 300 VUL 508 300 VCSA C22.2 No 14 400 V 3)EN/IEC 60947-1 |
Uimp Rated Imp Wstd Voltage | 4 kV EN/IEC 60947-5-1 |
Resistance Across Terminals | 30 mOhm EN/IEC 60947-5-4 |
Short-Circuit Protection | 6 A cartridge fuse gG (gl) |
Safety Level | Can reach category 4 with the appropriate monitoring system and correctly wired EN/ISO 13849-1 Can reach PL = e with the appropriate monitoring system and correctly wired EN/ISO 13849-1 Can reach SIL 3 with the appropriate monitoring system and correctly wired IEC 61508 |
Safety Reliability Data | B10d = 5000000 value given for a life time of 20 years limited by mechanical or contact wear |
Enclosure Material | Polyamide PA66 fibre glass impregnated |
Lever Material | Stainless steel |
Width | 2.05 in (52 mm) |
Height | 4.61 in (117 mm) |
Depth | 2.36 in (60 mm) |
Product Weight | 0.34 lb(US) (0.155 kg) |
Standards | EN/ISO 12100 EN/IEC 60947-5-1 EN/IEC 60204-1 CSA C22.2 No 14 EN 1088/ISO 14119 EN/IEC 60947-5-4 UL 508 |
Product Certifications | UL CSA BG |
Protective Treatment | TC TH |
Ambient Air Temp For Op | -13…158 °F (-25…70 °C) |
Ambient Air Temp For Storage | -40…158 °F (-40…70 °C) |
Vibration Resistance | 50 gn 10…500 Hz)IEC 60068-2-6 |
Shock Resistance | 50 gn 11 ms IEC 60068-2-27 |
Electrical Shock Protect Class | Class II EN/IEC 61140 |
IP Degree Of Protection | IP67 IEC 60529 |
Category | 22411 - LIMIT SWITCHES,IEC,XCKJ |
Discount Schedule | T |
GTIN | 03389110177244 |
Nbr. Of Units In Pkg. | 1 |
Country Of Origin | FR |
Green Premium Status | Green Premium product |
EU RoHs Directive | Pro-active compliance (Product out of EU RoHS legal scope) |
Powered by
Based on 2 User Reviews
1619 Boyd St, Santa Ana, CA 92705
(714) 835-6211
(714) 972-2366