Electrical distributor of high quality products to the LA and Orange County markets

Call Us Today To get a Quote
Safety limit switch XCSM – metal – rotary lever – 2 NC + 1 NO – cable 5 m
XCSM3916L5
Safety limit switch XCSM – metal – rotary lever – 2 NC + 1 NO – cable 5 m
Specifications
Part Number XCSM3916L5
Country of Origin ID
UPC 785901681106
UPC11 78590168110
EAN 3389110244090
Availability N
Lead Time 67
UNSPSC 39122213
ECCN EAR99
HTs Code 8536509055
Prop 65 This product can expose you to chemicals including: Di-isodecyl phthalate (DIDP) and Diisononyl phthalate (DINP) which is known to the State of California to cause Carcinogen and Reproductive harm. For more information go to www.p65warnings.ca.gov
RoHS Compliant Yes
Discount Schedule T
Return Indicator No
Depth 1.34 inch
Height 3.70 inch
Width 1.18 inch
Weight 0.46 pound
Characteristics
Range Of Product Preventa Safety detection
Product Or Component Type Safety limit switch
Component Name XCSM
Design Miniature
Material Metal
Head Type Rotary head
Protection Technology Plastic protective cover, secured by 5-lobe socket head safety screw
Type Of Approach Lateral approach
Type Of Operator Steel roller lever
Contacts Type And Composition 1 NC + 1 NC + 1 NO
Contact Operation Snap action
Electrical Connection Pre-cabled
Cable Length 16.40 ft (5 m)
Cable Composition 7 x 0.5 mm²
Switch Actuation By 30° cam
Fixing Mode By the body
Number Of Poles 3
Positive Opening With NC contact
Mechanical Durability 10000000 cycles
Minimum Torque For Tripping 4.43 lbf.in (0.5 N.m)
Positive Opening Min Torque 0.89 lbf.in (0.1 N.m)
Minimum Actuation Speed 0.01 m/min
Maximum Actuation Speed 4.92 ft/s (1.5 m/s)
Contact Code Designation B300, AC-15 (Ue = 240 V, Ie = 1.5 A)EN 60947-5-1 B300, AC-15 (Ue = 240 V, Ie = 1.5 A)EN/IEC 60947-5-1 appendix A R300, DC-13 (Ue = 250 V, Ie = 0.1 A)EN 60947-5-1 R300, DC-13 (Ue = 250 V, Ie = 0.1 A)EN/IEC 60947-5-1 appendix A
Ui Rated Insulation Voltage 300 VUL 508 400 V 3)IEC 60947-5-1 300 VCSA C22.2 No 14
Uimp Rated Imp Wstd Voltage 4 kV IEC 60664 4 kV IEC 60947-1
Resistance Across Terminals 25 MOhm IEC 60255-7 category 3
Short-Circuit Protection 6 A cartridge fuse gG (gl)
Repeat Accuracy 0.05 mm on the tripping points
Body Material Zamak
Head Material Zamak
Depth 1.34 in (34 mm)
Height 3.70 in (94 mm)
Width 1.18 in (30 mm)
Product Weight 0.46 lb(US) (0.21 kg)
Standards EN/IEC 60204-1 EN 1088 CSA C22.2 No 14 EN/IEC 60947-5-1 UL 508
Product Certifications UL CSA
Safety Level Can reach category 4 with the appropriate monitoring system and correctly wired EN/ISO 13849-1 Can reach PL = e with the appropriate monitoring system and correctly wired EN/ISO 13849-1 Can reach SIL 3 with the appropriate monitoring system and correctly wired IEC 61508
Safety Reliability Data B10d = 50000000 value given for a life time of 20 years limited by mechanical or contact wear
Protective Treatment TC
Ambient Air Temp For Op -13…158 °F (-25…70 °C)
Ambient Air Temp For Storage -40…158 °F (-40…70 °C)
Vibration Resistance 5 gn 10…500 Hz)IEC 60068-2-6
Shock Resistance 25 gn 18 ms IEC 60068-2-27
Electrical Shock Protect Class Class I NF C 20-030 Class I EN/IEC 61140
IP Degree Of Protection IP66 IEC 60529 IP67 IEC 60529 IP68 IEC 60529
IK Degree Of Protection IK06 EN 50102
Category 22411 - LIMIT SWITCHES,IEC,XCKJ
Discount Schedule T
GTIN 00785901681106
Documents
Royal Wholesale Electric

5.0

Powered by

Based on 2 User Reviews