This product is part of the XCS range, an offer of safety switches. The limit switch is a device that converts a mechanical motion into an electrical control signal. It has 2 normally closed + 1 normally opened, snap action contacts, normally closed contact with positive opening operation. It is a switch with a rated operational current of 1.5A at 240V AC, 0.1 at 250V DC. It is designed to operate in hazardous environments. It is furnished with a 10m pre-cabled (7 x 0.5mm²) for electrical connection. It supports minimum actuation speed of 0.01m/min and maximum actuation speed 0.5m/s. It offers long mechanical durability which is about 10 million operating cycles. It is an IP66, IP67, IP68 rated product. This plunger head limit switch has a fixed type body which is made of Zamak. Its dimensions are 30mm (Width) x 16mm (Depth) x 70mm (Height) and weighs 0.17kg. It is intended as far as safety is concerned all dangerous machines in all sectors are involved. Such as packaging, handling, robotics, machine tools, presses, automotive sector. This product is certified by CUL, CSA and UL. It meets CSA C22.2 No 14, EN/IEC 60204-1, EN/IEC 60947-5-1, EN 1088 and UL 508 standards. It offers protection of operators by stopping the machine when the actuator attached to the machine guard is withdrawn from the head of the switch. Safety switches for the protection of operators, by controlling the safe opening and interlocking of guards and covers in your installations.
Brand: Telemecanique
Add to Quote CataloguePart Number | XCSM3902L10 |
---|---|
UPC | 389119047012 |
UPC11 | 38911904701 |
EAN | 3389119047012 |
Availability | N |
Lead Time | 25 |
ECCN | EAR99 |
HTs Code | 8536509055 |
Prop 65 | This product can expose you to chemicals including: Di-isodecyl phthalate (DIDP) and Diisononyl phthalate (DINP) which is known to the State of California to cause Carcinogen and Reproductive harm. For more information go to www.p65warnings.ca.gov |
RoHS Compliant | Yes |
Discount Schedule | T |
Return Indicator | No |
Depth | 0.63 inch |
Height | 2.76 inch |
Width | 1.18 inch |
Weight | 0.37 pound |
Range Of Product | Preventa Safety detection |
---|---|
Product Or Component Type | Safety limit switch |
Component Name | XCSM |
Design | Miniature |
Material | Metal |
Head Type | Plunger head |
Protection Technology | Plastic protective cover, secured by 5-lobe socket head safety screw |
Type Of Approach | Lateral approach |
Type Of Operator | Roller plunger |
Contacts Type And Composition | 1 NC + 1 NC + 1 NO |
Contact Operation | Snap action |
Electrical Connection | Pre-cabled |
Cable Length | 32.81 ft (10 m) |
Cable Composition | 7 x 0.5 mm² |
Switch Actuation | By 30° cam |
Fixing Mode | By the body |
Number Of Poles | 3 |
Positive Opening | With NC contact |
Mechanical Durability | 10000000 cycles |
Minimum Force For Tripping | 7 N |
Positive Opening Min Force | 35 N |
Minimum Actuation Speed | 0.01 m/min |
Maximum Actuation Speed | 1.64 ft/s (0.5 m/s) |
Contact Code Designation | B300, AC-15 (Ue = 240 V, Ie = 1.5 A)EN 60947-5-1 B300, AC-15 (Ue = 240 V, Ie = 1.5 A)EN/IEC 60947-5-1 appendix A R300, DC-13 (Ue = 250 V, Ie = 0.1 A)EN 60947-5-1 R300, DC-13 (Ue = 250 V, Ie = 0.1 A)EN/IEC 60947-5-1 appendix A |
Ui Rated Insulation Voltage | 300 VUL 508 400 V 3)IEC 60947-5-1 300 VCSA C22.2 No 14 |
Uimp Rated Imp Wstd Voltage | 4 kV IEC 60664 4 kV IEC 60947-1 |
Resistance Across Terminals | 25 MOhm IEC 60255-7 category 3 |
Short-Circuit Protection | 6 A cartridge fuse gG (gl) |
Repeat Accuracy | 0.05 mm on the tripping points |
Body Material | Zamak |
Head Material | Zamak |
Depth | 0.63 in (16 mm) |
Height | 2.76 in (70 mm) |
Width | 1.18 in (30 mm) |
Product Weight | 0.37 lb(US) (0.17 kg) |
Standards | EN/IEC 60204-1 UL 508 CSA C22.2 No 14 EN/IEC 60947-5-1 EN 1088 |
Product Certifications | UL CSA |
Safety Level | Can reach category 4 with the appropriate monitoring system and correctly wired EN/ISO 13849-1 Can reach PL = e with the appropriate monitoring system and correctly wired EN/ISO 13849-1 Can reach SIL 3 with the appropriate monitoring system and correctly wired IEC 61508 |
Safety Reliability Data | B10d = 50000000 value given for a life time of 20 years limited by mechanical or contact wear |
Protective Treatment | TC |
Ambient Air Temp For Op | -13…158 °F (-25…70 °C) |
Ambient Air Temp For Storage | -40…158 °F (-40…70 °C) |
Vibration Resistance | 5 gn 10…500 Hz)IEC 60068-2-6 |
Shock Resistance | 25 gn 18 ms IEC 60068-2-27 |
Electrical Shock Protect Class | Class I NF C 20-030 Class I EN/IEC 61140 |
IP Degree Of Protection | IP66 IEC 60529 IP67 IEC 60529 IP68 IEC 60529 |
IK Degree Of Protection | IK06 EN 50102 |
Category | 22411 - LIMIT SWITCHES,IEC,XCKJ |
Discount Schedule | T |
GTIN | 03389119047012 |
Powered by