Electrical distributor of high quality products to the LA and Orange County markets

Call Us Today To get a Quote
Residual current protection relay, Vigirex RH99P, 30mA to 30A, 12 to 24VAC 50/60Hz, 12 to 48VDC, local manual reset
56270
Residual current protection relay, Vigirex RH99P, 30mA to 30A, 12 to 24VAC 50/60Hz, 12 to 48VDC, local manual reset

RH99P is a front panel mounting residual current protection relay. It protects against people direct or indirect contact, property fire hazards and motors. It measures the earth leakage current in an electrical installation via its associated toroid. It trips the associated circuit breaker when the set residual operation current is overrun. The operational supply voltage is from 12VDC to 24VDC, or 12VAC to 48VAC 50/60Hz. The current sensitivity is selectable with 9 thresholds from 30 mA to 30 A. The time delay is selectable with 9 settings from instantaneous to 4.5s. It requires a local manual reset after a fault clearance. The monitored distribution system voltage is up to 1000 VAC 50/60/400 Hz. It is installed on a front panel switchboard and the protection degree is IP40. It must be associated with a compatible Schneider Electric toroid.

Add to Quote Catalogue
Specifications
Part Number 56270
Country of Origin FR
UPC 785901803225
UPC11 78590180322
EAN 3303430562702
Availability N
Lead Time 19
HTs Code 8536410060
Prop 65 This product can expose you to chemicals including: DINP and DIDP which is known to the State of California to cause Carcinogen and Reproductive harm. For more information go to www.p65warnings.ca.gov
RoHS Compliant Yes
Discount Schedule DE2
Return Indicator No
Depth 3.07 inch
Height 2.83 inch
Width 2.83 inch
Weight 0.66 pound
Characteristics
Range Vigirex
Range Of Product Vigirex
Device Short Name RH99P
Product Or Component Type Residual current protection relay
Range Compatibility Vigirex RH TOA earth leakage current sensor Vigirex RH A earth leakage current sensor
Relay Application Residual current protection relay
Earthing System IT TN-S TT
[Us] Rated Supply Voltage 12...24 V AC 50/60 Hz 12...48 V DC
Power Consumption In Va 4 VA
Type Of Measurement Earth fault current internal measurement 80...100 %
Res E-L Time Delay Adj Type Instantaneous 0.03 A Adjustable 9 settings 0.03…30 A 0…4.5 s
Test Function Remote test Local
Monitoring Electronics continuous) Power supply continuous) Relay/sensor link continuous)
Ithe Cnvtl Enclosed Therm Crrt 8 A
Minimum Load 10 mA 12 V
Product Weight 0.66 lb(US) (0.3 kg)
Mechanical Robustness Fire resistance IEC 60695-2-1 IK protection 2 joulesIK07 EN 50102 IP protectionIP20 IEC 60529 IP protectionIP30 IEC 60529 IP protectionIP40 IEC 60529 Vibrations 13.2...100 Hz0.7 g Vibrations 2...13.2 Hz+/- 1 mm
Earth-Leakage Protection Class Class A si Class AC
Overvoltage Category IV
Tamperproof Of Settings Protected by sealable cover
Mounting Support Panel
Height 2.83 in (72 mm)
Width 2.83 in (72 mm)
Depth 3.07 in (78 mm)
Connections - Terminals Auxiliary power supply terminal block 0.00…0.00 in² (0.2…2.5 mm²) flexible AWG 24...AWG 12 Auxiliary power supply terminal block 0.00…0.00 in² (0.2…2.5 mm²) rigid AWG 24...AWG 12 Auxiliary power supply terminal block 0.00…0.00 in² (0.25…2.5 mm²) flexible AWG 24...AWG 12 Fault terminal block 0.00…0.00 in² (0.2…2.5 mm²) flexible AWG 24...AWG 12 Fault terminal block 0.00…0.00 in² (0.2…2.5 mm²) rigid AWG 24...AWG 12 Fault terminal block 0.00…0.00 in² (0.25…2.5 mm²) flexible AWG 24...AWG 12 Relay test and fault reset terminal block 0.00…0.00 in² (0.2…2.5 mm²) flexible AWG 24...AWG 12 Relay test and fault reset terminal block 0.00…0.00 in² (0.2…2.5 mm²) rigid AWG 24...AWG 12 Relay test and fault reset terminal block 0.00…0.00 in² (0.25…2.5 mm²) flexible AWG 24...AWG 12 Sensor terminal block 0.00…0.00 in² (0.2…2.5 mm²) flexible AWG 24...AWG 12 Sensor terminal block 0.00…0.00 in² (0.2…2.5 mm²) rigid AWG 24...AWG 12 Sensor terminal block 0.00…0.00 in² (0.25…2.5 mm²) flexible AWG 24...AWG 12 Voltage presence terminal block 0.00…0.00 in² (0.2…2.5 mm²) flexible AWG 24...AWG 12 Voltage presence terminal block 0.00…0.00 in² (0.2…2.5 mm²) rigid AWG 24...AWG 12 Voltage presence terminal block 0.00…0.00 in² (0.25…2.5 mm²) flexible AWG 24...AWG 12
Wire Stripping Length Auxiliary power supply 0.28 in (7 mm) Fault 0.28 in (7 mm) Relay test and fault reset 0.28 in (7 mm) Sensor 0.28 in (7 mm) Voltage presence 0.28 in (7 mm)
Tightening Torque Auxiliary power supply 5.31 lbf.in (0.6 N.m) Fault 5.31 lbf.in (0.6 N.m) Relay test and fault reset 5.31 lbf.in (0.6 N.m) Sensor 5.31 lbf.in (0.6 N.m) Voltage presence 5.31 lbf.in (0.6 N.m)
Ambient Air Temp For Op -31…158 °F (-35…70 °C)
Ambient Air Temp For Storage -67…185 °F (-55…85 °C)
Electromagnetic Compatibility Conducted and radiated emissionsB CISPR 11 Conducted radio-frequency immunity test3 IEC 61000-4-6 Electrostatic discharge immunity test4 IEC 61000-4-2 High-energy conducted susceptibility4 IEC 61000-4-5 Low-energy conducted susceptibility4 IEC 61000-4-4 Radiated susceptibility3 IEC 61000-4-3
Electrical Shock Protect Class Class II
Category 01101-NF..E COMPACT NS IEC BRKR/SW/MCP
Discount Schedule DE2
GTIN 00785901803225
Nbr. Of Units In Pkg. 1
Country Of Origin FR
Green Premium Status Green Premium product
EU RoHs Directive Compliant
Mercury Free Yes
WEEE The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
Warranty 18 months
Documents