RH99P is a front panel mounting residual current protection relay. It protects against people direct or indirect contact, property fire hazards and motors. It measures the earth leakage current in an electrical installation via its associated toroid. It trips the associated circuit breaker when the set residual operation current is overrun. The operational supply voltage is from 220 VAC to 240 VAC 50/60Hz. The current sensitivity is selectable with 9 thresholds from 30 mA to 30 A. The time delay is selectable with 9 settings from instantaneous to 4.5s. It requires a local manual reset after a fault clearance. The monitored distribution system voltage is up to 1000 VAC 50/60/400 Hz. It is installed on a front panel switchboard and the protection degree is IP40. It must be associated with a compatible Schneider Electric toroid.
Add to Quote CataloguePart Number | 56273 |
---|---|
UPC | 303430562733 |
UPC11 | 30343056273 |
EAN | 3303430562733 |
Availability | N |
Lead Time | 19 |
ECCN | EAR99 |
HTs Code | 8537109170 |
Prop 65 | This product can expose you to chemicals including: DINP and DIDP which is known to the State of California to cause Carcinogen and Reproductive harm. For more information go to www.p65warnings.ca.gov |
RoHS Compliant | Yes |
Discount Schedule | DE2 |
Return Indicator | No |
Depth | 3.07 inch |
Height | 2.83 inch |
Width | 2.83 inch |
Weight | 0.66 pound |
Range | Vigirex |
---|---|
Range Of Product | Vigirex |
Device Short Name | RH99P |
Product Or Component Type | Residual current protection relay |
Range Compatibility | Vigirex RH TOA earth leakage current sensor Vigirex RH A earth leakage current sensor |
Relay Application | Residual current protection relay |
Earthing System | IT TT TN-S |
[Us] Rated Supply Voltage | 220...240 V AC 50/60 Hz 220...240 V AC 400 Hz |
Power Consumption In Va | 4 VA |
Type Of Measurement | Earth fault current internal measurement 80...100 % |
Res E-L Time Delay Adj Type | Instantaneous 0.03 A Adjustable 9 settings 0.03…30 A 0…4.5 s |
Test Function | Local Remote test |
Monitoring | Electronics continuous) Power supply continuous) Relay/sensor link continuous) |
Ithe Cnvtl Enclosed Therm Crrt | 8 A |
Minimum Load | 10 mA 12 V |
Product Weight | 0.66 lb(US) (0.3 kg) |
Mechanical Robustness | Fire resistance IEC 60695-2-1 IK protection 2 joulesIK07 EN 50102 IP protectionIP20 IEC 60529 IP protectionIP30 IEC 60529 IP protectionIP40 IEC 60529 Vibrations 13.2...100 Hz0.7 g Vibrations 2...13.2 Hz+/- 1 mm |
Earth-Leakage Protection Class | Class AC Class A si |
Overvoltage Category | IV |
Tamperproof Of Settings | Protected by sealable cover |
Mounting Support | Panel |
Height | 2.83 in (72 mm) |
Width | 2.83 in (72 mm) |
Depth | 3.07 in (78 mm) |
Connections - Terminals | Auxiliary power supply terminal block 0.00…0.00 in² (0.2…2.5 mm²) flexible AWG 24...AWG 12 Auxiliary power supply terminal block 0.00…0.00 in² (0.2…2.5 mm²) rigid AWG 24...AWG 12 Auxiliary power supply terminal block 0.00…0.00 in² (0.25…2.5 mm²) flexible AWG 24...AWG 12 Fault terminal block 0.00…0.00 in² (0.2…2.5 mm²) flexible AWG 24...AWG 12 Fault terminal block 0.00…0.00 in² (0.2…2.5 mm²) rigid AWG 24...AWG 12 Fault terminal block 0.00…0.00 in² (0.25…2.5 mm²) flexible AWG 24...AWG 12 Relay test and fault reset terminal block 0.00…0.00 in² (0.2…2.5 mm²) flexible AWG 24...AWG 12 Relay test and fault reset terminal block 0.00…0.00 in² (0.2…2.5 mm²) rigid AWG 24...AWG 12 Relay test and fault reset terminal block 0.00…0.00 in² (0.25…2.5 mm²) flexible AWG 24...AWG 12 Sensor terminal block 0.00…0.00 in² (0.2…2.5 mm²) flexible AWG 24...AWG 12 Sensor terminal block 0.00…0.00 in² (0.2…2.5 mm²) rigid AWG 24...AWG 12 Sensor terminal block 0.00…0.00 in² (0.25…2.5 mm²) flexible AWG 24...AWG 12 Voltage presence terminal block 0.00…0.00 in² (0.2…2.5 mm²) flexible AWG 24...AWG 12 Voltage presence terminal block 0.00…0.00 in² (0.2…2.5 mm²) rigid AWG 24...AWG 12 Voltage presence terminal block 0.00…0.00 in² (0.25…2.5 mm²) flexible AWG 24...AWG 12 |
Wire Stripping Length | Auxiliary power supply 0.28 in (7 mm) Fault 0.28 in (7 mm) Relay test and fault reset 0.28 in (7 mm) Sensor 0.28 in (7 mm) Voltage presence 0.28 in (7 mm) |
Tightening Torque | Auxiliary power supply 5.31 lbf.in (0.6 N.m) Fault 5.31 lbf.in (0.6 N.m) Relay test and fault reset 5.31 lbf.in (0.6 N.m) Sensor 5.31 lbf.in (0.6 N.m) Voltage presence 5.31 lbf.in (0.6 N.m) |
Ambient Air Temp For Op | -31…158 °F (-35…70 °C) |
Ambient Air Temp For Storage | -67…185 °F (-55…85 °C) |
Electromagnetic Compatibility | Conducted and radiated emissionsB CISPR 11 Conducted radio-frequency immunity test3 IEC 61000-4-6 Electrostatic discharge immunity test4 IEC 61000-4-2 High-energy conducted susceptibility4 IEC 61000-4-5 Low-energy conducted susceptibility4 IEC 61000-4-4 Radiated susceptibility3 IEC 61000-4-3 |
Electrical Shock Protect Class | Class II |
Category | 01101-NF..E COMPACT NS IEC BRKR/SW/MCP |
Discount Schedule | DE2 |
GTIN | 03303430562733 |
Nbr. Of Units In Pkg. | 1 |
Green Premium Status | Green Premium product |
EU RoHs Directive | Compliant |
Mercury Free | Yes |
WEEE | The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins. |
Warranty | 18 months |