Part Number | TM5SDO2DTRFS |
---|---|
Country of Origin | AT |
UPC | 606480941177 |
UPC11 | 60648094117 |
EAN | 3606480941177 |
Availability | N |
Lead Time | 47 |
ECCN | EAR99 |
HTs Code | 8536908585 |
Prop 65 | This product can expose you to chemicals including: Lead and lead compounds which is known to the State of California to cause Carcinogen & Reproductive harm. For more information go to www.p65warnings.ca.gov |
RoHS Compliant | Yes |
Discount Schedule | PC52 |
Return Indicator | No |
Weight | 0.22 pound |
Range Of Product | Modicon TM5 |
---|---|
Product Or Component Type | Discrete output module |
Discrete Output Number | 2 |
Discrete Output Type | Relay |
Range Compatibility | PacDrive LMC motion controller |
Product Compatibility | PacDrive LMC Pro 2 PacDrive LMC Pro PacDrive LMC Eco |
Output Voltage | 24 V DC 230 V AC |
Output Voltage Limits | 5...230 V AC 5...24 V DC |
Discrete Output Function | 2 NO |
Current Per Channel | 6 A |
Colour | Red |
Response Time | <= 50 ms |
Protection Type | Reverse polarity protection Without short-circuit protection Without overload protection |
ISOlation | No insulation between channels 500 Vrms AC insulation between channel and bus |
Power Consumption In W | 1.15 W internal 0.26 W bus |
Power Dissipation In W | 2.3 W |
Marking | CE |
Safety Level | SIL 3 IEC 61508 SIL 3 IEC 62061 PL = e EN 13849-1 |
Safety Reliability Data | MTTFd > 100 years PFD < 1E-5 PFH < 1E-9 B10d = 780000 DC-1, 24 V, <6 A B10d = 780000 AC-1, 230 V, <6 A B10d = 1960000 AC-15, 230 V, <3 A B10d = 780000 DC-15, 24 V, <5 A |
Product Weight | 0.22 lb(US) (0.101 kg) |
Standards | IEC 61508 UL 508 EN 13849-1 IEC 62061 |
Product Certifications | CULus |
Ambient Air Temp For Op | 32…122 °F (0…50 °C) vertical installation) 32…131 °F (0…55 °C) without derating horizontal installation) 32…140 °F (0…60 °C) with derating factor horizontal installation) |
Ambient Air Temp For Storage | -13…158 °F (-25…70 °C) |
Relative Humidity | 5…95 % without condensation |
IP Degree Of Protection | IP20IEC 61131-2 |
Pollution Degree | 2 IEC 60664 |
Operating Altitude | 0...6561.68 ft (0...2000 m) |
Storage Altitude | 0.00…9842.52 ft (0…3000 m) |
Vibration Resistance | 1 gn 8.4…150 Hz DIN rail 3.5 mm 5…8.4 Hz DIN rail |
Shock Resistance | 15 gn 11 ms |
Electromagnetic Compatibility | Electrostatic discharge immunity test, 4 kV on contact EN/IEC 61000-4-2 Electrostatic discharge immunity test, 8 kV in air EN/IEC 61000-4-2 Susceptibility to electromagnetic fields, 1 V/m 2...2.7 GHz EN/IEC 61000-4-3 Susceptibility to electromagnetic fields, 10 V/m 80...2000 MHz EN/IEC 61000-4-3 Electrical fast transient/burst immunity test, 1 kV I/O EN/IEC 61000-4-4 Electrical fast transient/burst immunity test, 1 kV shielded cable EN/IEC 61000-4-4 Electrical fast transient/burst immunity test, 2 kV power lines EN/IEC 61000-4-4 1.2/50 µs shock waves immunity test, 0.5 kV differential mode EN/IEC 61000-4-5 1.2/50 µs shock waves immunity test, 1 kV common mode EN/IEC 61000-4-5 Conducted RF disturbances EN/IEC 61000-4-6 Conducted and radiated emissions CISPR 11 |
Category | 18360 - PACDRIVE3 SAFETY |
Discount Schedule | PC52 |
GTIN | 03606480941177 |
Nbr. Of Units In Pkg. | 1 |
Country Of Origin | AT |
Green Premium Status | Green Premium product |
REACh Free Of SVHC | Yes |
EU RoHs Directive | Pro-active compliance (Product out of EU RoHS legal scope) |
Toxic Heavy Metal Free | Yes |
Mercury Free | Yes |
WEEE | The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins. |
Pvc Free | Yes |
Powered by
Based on 2 User Reviews
1619 Boyd St, Santa Ana, CA 92705
(714) 835-6211
(714) 972-2366