This toroid is dedicated to Vigirex residual current protection and monitoring relays. The inner dimensions of the toroid are 280mm X 155mm and the weight is 11kg. The wiring size must be from 0.5 to 2.5 mm². The wiring length should not exceed 10m. It allows the measurement of a current rating up to 1600A for Vigirex monitoring and protection relays. The Vigirex sensitivity must be set over 300mA.
Add to Quote CataloguePart Number | 56053 |
---|---|
Country of Origin | FR |
UPC | 785901502302 |
UPC11 | 78590150230 |
EAN | 3303430560531 |
Availability | N |
Lead Time | 30 |
HTs Code | 9030333800 |
Prop 65 | This product can expose you to chemicals including: DINP and DIDP which is known to the State of California to cause Carcinogen and Reproductive harm. For more information go to www.p65warnings.ca.gov |
RoHS Compliant | Yes |
Discount Schedule | DE2 |
Return Indicator | No |
Depth | 2.80 inch |
Height | 9.17 inch |
Width | 15.00 inch |
Weight | 29.23 pound |
Range | Vigirex |
---|---|
Product Or Component Type | Earth leakage current sensor |
Device Application | Equipment monitoring and control |
Range Compatibility | Vigirex RH plug-in relay |
Ie Rated Operational Current | 1600 A |
Current Sensor Type | Rectangular sensor |
Transformer Ratio | 1/1000 |
Icw Rated Short-Time Wstd Crrt | 100 kA 0.5 s |
Res Sc Withstand Current | 85 kA / 0.5 s |
Overvoltage Category | IV |
Uimp Rated Imp Wstd Voltage | 12 kV |
Mounting Mode | Fixed cables) Fixed busbar) |
Connections - Terminals | Screw connection 0.00…0.00 in² (0.2…2.5 mm²) |
Product Weight | 29.23 lb(US) (13.26 kg) |
Height | Outside 9.17 in (233 mm) Inside 4.53 in (115 mm) |
Width | Outside 15.00 in (381 mm) Inside 11.02 in (280 mm) |
Height | 9.17 in (233 mm) |
Depth | Outside 2.80 in (71 mm) Inside 2.80 in (71 mm) |
Width | 15.00 in (381 mm) |
Depth | 2.80 in (71 mm) |
IP Degree Of Protection | Connectors IP20 IP30 |
Environmental Characteristic | Exposure to damp heat not in service 25...55 °C, RH 95 %) 28 cycles IEC 60068-2-30 Salt mistKb/2 IEC 60068-2-52 Exposure to damp heat in servicecategory C2 48 hours IEC 60068-2-56 |
Ambient Air Temp For Op | -31…176 °F (-35…80 °C) |
Ambient Air Temp For Storage | -67…212 °F (-55…100 °C) |
Category | 00992-UL VIGIREX GFR & SENSOR |
Discount Schedule | DE2 |
GTIN | 00785901502302 |
Nbr. Of Units In Pkg. | 1 |
Country Of Origin | FR |
Green Premium Status | Green Premium product |
EU RoHs Directive | Compliant |
Mercury Free | Yes |
WEEE | The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins. |
Warranty | 18 months |
Powered by
Based on 2 User Reviews
1619 Boyd St, Santa Ana, CA 92705
(714) 835-6211
(714) 972-2366