Part Number | 9013GHR2J57X |
---|---|
Country of Origin | MX |
UPC | 785901561453 |
UPC11 | 78590156145 |
EAN | 0785901561453 |
Availability | N |
Lead Time | 5 |
UNSPSC | 39122210 |
HTs Code | 9032200000 |
Prop 65 | This product can expose you to chemicals including: Lead and lead compounds which is known to the State of California to cause Carcinogen & Reproductive harm. For more information go to www.p65warnings.ca.gov |
Discount Schedule | CP7G |
Return Indicator | No |
Depth | 5.38 inch |
Height | 8.46 inch |
Width | 7.13 inch |
Weight | 2.25 pound |
Range Of Product | Square D Pumptrol |
---|---|
Pressure Sensor Name | 9013GH |
Pressure Sensor Size | 200 psi (1378.95 kPa) 35…150 psi (241.32…1034.21 kPa)) |
Value Of Setting | 120...150 psi |
Electrical Circuit Type | Power circuit |
Product Specific Application | Control electrically driven water pumps and air compressors |
Quantity Per Set | 1 |
Type Of Packing | Individual |
Pressure Sensor Type | Electromechanical pressure switch |
Controlled Fluid | Air -22…257 °F (-30…125 °C)) Fresh water -22…257 °F (-30…125 °C)) |
Adj Range On Rising Pressure | 65…200 psi (448.16…1378.95 kPa) |
Approximate Adj Differential | 30…60 psi (206.84…413.69 kPa) |
Destruction Pressure | 250 psi (1723.69 kPa) |
Pressure Actuator | Diaphragm |
Pressure Swt Type Of Operation | Regulation between 2 thresholds |
Type Of Scale | Adjustable differential |
Setting | Internal |
Local Display | Without |
Contacts Type And Composition | 2 NC, snap action, DPST-DB, Form YY |
Cable Entry Number | 2 conduit entries for 3/4"-14 NPT UL 508 |
Electrical Connection | Screw-clamp terminals 10 AWG Screw-clamp terminals 5.261 mm² |
Fluid Connection Type | 0.25 inch NPSF internal UL 508 |
Short-Circuit Protection | 20 A cartridge fuse gG |
Materials In Contact Wth Fluid | Zinc plated steel or equivalent flange Nitrile (Buna-N) or equivalent rubber diaphragm |
Material | Cast aluminium enclosure |
Operating Position | Any position |
Motor Power kW | 1.5 kW 2 hp)115 V AC, 1 phase 2.2 kW 3 hp)115 V AC, 3 phase 2.2 kW 3 hp)230 V AC, 1 phase 0.75 kW 1 hp)115 V DC 0.75 kW 1 hp)230 V DC 3.75 kW 5 hp)230 V AC, 3 phase 3.7 kW 5 hp)460 V AC, 1 phase 3.7 kW 5 hp)460 V AC, 3 phase 3.7 kW 5 hp)575 V AC, 1 phase 3.7 kW 5 hp)575 V AC, 3 phase |
Electrical Durability | 100000 cycles 10 cyc/mn |
Mechanical Durability | 300000 cycles |
Terminal Block Type | 4 terminals |
Operating Rate | 10 cyc/mn |
Ui Rated Insulation Voltage | 575 V UL 508 |
Product Weight | 2.25 lb(US) (1.02 kg) |
Repeat Accuracy | +/- 3 % |
Terminals Description ISO n°1 | L1-T1 L2-T2 |
Width | 7.13 in (181.10 mm) |
Height | 8.46 in (214.88 mm) |
Depth | 5.38 in (136.65 mm) |
Factory Modification | 2-way pressure release valve |
Standards | CE UL 508 NSF ANSI 372 |
Ambient Air Temp For Op | -27…495 °F (-33…257 °C) |
Ambient Air Temp For Storage | -27…495 °F (-33…257 °C) |
Protective Treatment | None |
Nema Degree Of Protection | NEMA 7 UL 698 NEMA 9 |
IP Degree Of Protection | IP20 IEC 60529 |
Product Certifications | CSA file LR26817 UL listed file E12443 |
Category | 21536 - 9013 G COMMERCIAL PRESSURE SWITCH |
Discount Schedule | CP7G |
GTIN | 00785901561453 |
Nbr. Of Units In Pkg. | 1 |