Electrical distributor of high quality products to the LA and Orange County markets

Call Us Today To get a Quote
Pressure switch XMLD 160 bar – 2 stages fixed scale – 2 C/O
XMLD160E1S11
Pressure switch XMLD 160 bar – 2 stages fixed scale – 2 C/O
Specifications
Part Number XMLD160E1S11
UPC 389110717082
UPC11 38911071708
EAN 3389110717082
Prop 65 This product can expose you to chemicals including: Di-isodecyl phthalate (DIDP) and Diisononyl phthalate (DINP) which is known to the State of California to cause Carcinogen and Reproductive harm. For more information go to www.p65warnings.ca.gov
RoHS Compliant Yes
Depth 3.35 inch
Height 4.45 inch
Width 1.81 inch
Weight 1.65 pound
Characteristics
Range Of Product OsiSense XM
Product Or Component Type Electromechanical pressure sensor
Pressure Sensor Type Electromechanical pressure sensor
Device Short Name XMLD
Pressure Sensor Size 2320.60 psi (160 bar)
Controlled Fluid Fresh water 32…320 °F (0…160 °C))
Fluid Connection Type G 1/4 (female) ISO 228
Electrical Connection Screw-clamps terminals, 1 x 0.5...2 x 2.5 mm²
Awg Gauge AWG 20...AWG 14
Cable Entry Cable gland 0.35…0.51 in (9…13 mm)
Contacts Type And Composition 2 C/O snap action, silver contacts 2 C/O staggered, silver contacts
Product Specific Application Dual stage
Pressure Swt Type Of Operation Detection of 2 single thresholds
Electrical Circuit Type Control circuit
Type Of Scale Fixed differential
Local Display Without
Max Perm Accidental Pressure 5221.36 psi (360 bar)
Destruction Pressure 10442.72 psi (720 bar)
Pressure Actuator Piston
Materials In Contact Wth Fluid 316L stainless steel FPM, FKM PTFE Brass
Enclosure Material Zinc alloy
In Rated Current 3 A, B300, AC-15 (Ue = 120 V)EN/IEC 60947-5-1 1.5 A, B300, AC-15 (Ue = 240 V)EN/IEC 60947-5-1 0.1 A, R300, DC-13 (Ue = 250 V)EN/IEC 60947-5-1
Spread Between 2 Stages 87.02…1203.81 psi (6…83 bar)
Natural Diff At Low Setting 127.63 psi (8.8 bar)
Natural Diff At High Setting 290.08 psi (20 bar)
Max Perm Pressure - Per Cycle 2900.75 psi (200 bar)
Terminal Block Type 8 terminals
Operating Rate 60 cyc/mn
Repeat Accuracy 2 %
Ui Rated Insulation Voltage 300 V UL 508 500 V EN/IEC 60947-1 300 V CSA C22.2 No 14
Uimp Rated Imp Wstd Voltage 6 kV EN/IEC 60947-1
Resistance Across Terminals 25 mOhm IEC 255-7 category 3 25 mOhm NF C 93-050 method A
Short-Circuit Protection 10 A cartridge fuse gG (gl)
Mechanical Durability 6000000 cycles
Setting External
Height 4.45 in (113 mm)
Depth 3.35 in (85 mm)
Width 1.81 in (46 mm)
Product Weight 1.65 lb(US) (0.75 kg)
Standards UL 508 CE EN/IEC 60947-5-1 CSA C22.2 No 14
Product Certifications CSA EAC UL
Protective Treatment TC standard version
Ambient Air Temp For Op -13…158 °F (-25…70 °C)
Ambient Air Temp For Storage -40…158 °F (-40…70 °C)
Operating Position Any position
Vibration Resistance 4 gn 30…500 Hz)IEC 60068-2-6
Shock Resistance 50 gn IEC 60068-2-27
Electrical Shock Protect Class Class I IEC 1140 Class I IEC 536 Class I NF C 20-030
IP Degree Of Protection IP66 EN/IEC 60529
GTIN 03389110717082
Documents
Royal Wholesale Electric

5.0

Powered by

Based on 2 User Reviews