Part Number | XMPA12C2141 |
---|---|
Country of Origin | CZ |
UPC | 389110704839 |
UPC11 | 38911070483 |
EAN | 3389110704839 |
Availability | F |
Lead Time | 19 |
UNSPSC | 39122210 |
ECCN | EAR99 |
HTs Code | 9032200000 |
Prop 65 | This product can expose you to chemicals including: Di-isodecyl phthalate (DIDP) and Diisononyl phthalate (DINP) which is known to the State of California to cause Carcinogen and Reproductive harm. For more information go to www.p65warnings.ca.gov |
RoHS Compliant | Yes |
Discount Schedule | DS2 |
Return Indicator | No |
Depth | 3.86 inch |
Height | 4.17 inch |
Width | 2.24 inch |
Range Of Product | OsiSense XM |
---|---|
Pressure Sensor Type | Electromechanical pressure sensor |
Pressure Sensor Name | XMP |
Pressure Sensor Size | 174.05 psi (12 bar) |
Fluid Connection Type | G 1/4 (female) ISO 228 |
Controlled Fluid | Air 32…158 °F (0…70 °C)) Fresh water 32…158 °F (0…70 °C)) Sea water 32…158 °F (0…70 °C)) |
Cable Entry | 2 entries incorporating Pg 13.5 plastic cable gland 0.35…0.51 in (9…13 mm) NF C 68-300 |
Contacts Type And Composition | 3 NC snap action |
Pressure Swt Type Of Operation | Regulation between 2 thresholds |
Electrical Connection | Screw-clamp terminals minimum : 2 x 4 mm² |
Electrical Circuit Type | Power circuit |
Type Of Scale | Adjustable differential |
Local Display | Without |
Sale Per Indivisible Qty | 1 |
Adj Range Low Setting | 4.35…149.39 psi (0.3…10.3 bar) |
Adjustment Range High Setting | 18.85…174.05 psi (1.3…12 bar) |
Possible Diff Min At Low Setg | 14.50 psi (1 bar) |
Possible Diff Min At High Setg | 24.66 psi (1.7 bar) |
Possible Diff Max At High Setg | 121.83 psi (8.4 bar) |
Destruction Pressure | 435.11 psi (30 bar) |
Type Of Decompression Valve | Without |
Control Type | Without |
Terminal Block Type | 6 terminals |
Pressure Actuator | Diaphragm |
Materials In Contact Wth Fluid | Canvas covered nitrile Chromated zinc alloy |
Enclosure Material | PA impregnated with fibreglass |
Operating Position | Any position |
Operating Rate | 10 cyc/mn |
Repeat Accuracy | 3.5 % |
Ui Rated Insulation Voltage | 500 V EN/IEC 60947-1 |
Uimp Rated Imp Wstd Voltage | 6 kV EN/IEC 60947-1 |
Resistance Across Terminals | 25 MOhm IEC 60255-7 category 3 25 MOhm NF C 93-050 method A |
Electrical Durability | 1000000 cycles 1.5 kW 10 cyc/mn 0.4, 400 V AC 3 phase 500000 cycles 3 kW 10 cyc/mn 0.4, 400 V AC 3 phase 600000 cycles 1.5 kW 10 cyc/mn 0.4, 230 V AC 3 phase 700000 cycles 2.2 kW 10 cyc/mn 0.4, 400 V AC 3 phase |
Mechanical Durability | 1000000 cycles |
Setting | Nut |
Terminals Description ISO n°1 | (3-4)NC (1-2)NC (5-6)NC |
Depth | 3.86 in (98 mm) |
Height | 4.17 in (106 mm) |
Width | 2.24 in (57 mm) |
Product Certifications | EAC |
Standards | CE EN/IEC 60947-4-1 |
Ambient Air Temp For Op | -13…158 °F (-25…70 °C) |
Ambient Air Temp For Storage | -40…158 °F (-40…70 °C) |
Vibration Resistance | 3 gn 10…500 Hz)IEC 60068-2-6 |
Shock Resistance | 50 gn IEC 60068-2-27 |
Electrical Shock Protect Class | Class I IEC 60536 |
IP Degree Of Protection | IP54 EN/IEC 60529 |
Category | 22661 - XMLA,B,C,D PRESSURE SWITCHES |
Discount Schedule | DS2 |
GTIN | 03389110704839 |
Powered by
Based on 2 User Reviews
1619 Boyd St, Santa Ana, CA 92705
(714) 835-6211
(714) 972-2366