Electrical distributor of high quality products to the LA and Orange County markets

Call Us Today To get a Quote
PowerPact multistandard – L-Frame – 600 A – 25 KA – Micrologic 5.3 A trip unit
NLDF36600U53XTW
PowerPact multistandard – L-Frame – 600 A – 25 KA – Micrologic 5.3 A trip unit
Specifications
Part Number NLDF36600U53XTW
Country of Origin US
UPC 785901861478
UPC11 78590186147
EAN 0785901861478
Availability N
Lead Time 4
UNSPSC 39121601
ECCN EAR99
HTs Code 8536200020
Prop 65 This product can expose you to chemicals including: DINP and DIDP which is known to the State of California to cause Carcinogen and Reproductive harm. For more information go to www.p65warnings.ca.gov
RoHS Compliant Yes
Discount Schedule DE2
Return Indicator No
Depth 4.33 inch
Height 13.39 inch
Width 5.51 inch
Weight 13.67 pound
Characteristics
Range Of Product PowerPact multistandard
Range PowerPact
Product Name L-Frame
Device Short Name L-Frame
Product Or Component Type Circuit breaker
Device Application Distribution
Poles Description 3P
Control Type Toggle
Mounting Mode Unit mount
Mounting Support Backplate DIN rail Flush
Electrical Connection Terminal nut line side Terminal nut load side
In Rated Current 600 A 104 °F (40 °C)
Ui Rated Insulation Voltage 750 V AC 50/60 Hz IEC 60947-2
Uimp Rated Imp Wstd Voltage 8 kV IEC 60947-2
Ue Rated Operational Voltage 525 V AC 50/60 Hz IEC 60947-2 690 V AC 50/60 Hz IEC 947-2 600 V AC 50/60 Hz UL 489
Rating Code LD
Suitability For ISOlation Yes
Utilisation Category Category A
Mechanical Durability 5000 cycles
Electrical Durability 1000 cycles
Connection Pitch 1.77 in (45 mm)
Local Signalling ON/OFF indication
Contact Position Indicator Yes
Trip Unit Name Micrologic 5.3 A
Trip Unit Technology Electronic
Trip Unit Protection Functions LSI
Trip Unit Rating 600 A
Thermal Memory 20 mn
Display Type Digital display
Breaking Capacity Icu 25 kA 220/240 V - AC IEC 947-2 Icu 18 kA 380/415 V - AC IEC 947-2 Icu 18 kA 440/480 V - AC IEC 947-2 Icu 14 kA 500/525 V - AC IEC 947-2 25 kA 240 V - AC UL 489 18 kA 480 V - AC UL 489 14 kA 600 V - AC UL 489
Ics Rated Service Breaking Cap Ics 25 kA 220/240 V - AC IEC 947-2 Ics 18 kA 380/415 V - AC IEC 947-2 Ics 18 kA 440/480 V - AC IEC 947-2 Ics 14 kA 500/525 V - AC IEC 947-2
Lg Time Pick Up Adj Type Ir Adjustable 9 settings
Long Time Pick-Up Adjust Rng 0.33...1 x In
Tr Long-Time Delay Adjust Rng 1 s 0.5 s 2 s 4 s 8 s 16 s
Sh Time Pick-Up Adj Type Isd Adjustable 9 settings
Isd Short-Time Pick-Up Adj 1.5...9.5 x Ir
Tsd Short-Time Delay Adj 0 s 0.1 s 0.3 s 0.2 s 0.4 s
Instt Pick Up Adj Type Ii Adjustable 9 settings
Instant Pick-Up Adj Range 1.5...11 x In
Overvoltage Category II
Provision For Padlocking Non padlockable
Height 13.39 in (340 mm)
Width 5.51 in (140 mm)
Depth 4.33 in (110 mm)
Standards IEC 60947-2 NMX J-266 W-C-375B/GEN CSA C22.2 No 5 UL 489 NEMA AB1
Product Certifications CE CCC
Product Weight 13.67 lb(US) (6.2 kg)
Tightening Torque 442.54 lbf.in (50 N.m)
IP Degree Of Protection IP40 IEC 60529
IK Degree Of Protection IK07 IEC 62262
Documents
Royal Wholesale Electric

5.0

Powered by

Based on 2 User Reviews