Electrical distributor of high quality products to the LA and Orange County markets

Call Us Today To get a Quote
Plastic safety switch XCSTE – 2 NC – slow break – 1 entry tapped Pg 11 – 24 V
XCSTE7311
Plastic safety switch XCSTE – 2 NC – slow break – 1 entry tapped Pg 11 – 24 V

This XCSTE Key Operated Safety Switch for guard doors with locking by solenoid has an adjustable turret head and a red coated polyamide body with a Pg 11 cable gland entry, allowing for flexible installation. It has 2 normally closed simultaneous (slow break) main contacts actuated by key, contact states given when the key is inserted. And it has 1 normally closed auxiliary contacts actuated by the solenoid, contact states given when the solenoid is not powered. Its B10D reliability data is 5 000 000. Its IP67 degree of protection makes it ideal for heavy duty use in harsh conditions. It also complies with EN/ISO 14119, EN/IEC 60204-1, EN/IEC 60947-5-1, UL 508, CSA C22.2 No 14 standards. When associated and correctly connected to an appropriate safety control unit, it conforms to Category 4, performance level PL e, SIL 3 as described in EN/ISO 13849-1, EN/IEC 61508.

Brand: Telemecanique

Add to Quote Catalogue
Specifications
Part Number XCSTE7311
Country of Origin FR
UPC 785901712411
UPC11 78590171241
EAN 3389110825107
Availability N
Lead Time 33
UNSPSC 39122213
ECCN EAR99
HTs Code 8536509065
Prop 65 This product can expose you to chemicals including: Di-isodecyl phthalate (DIDP) and Diisononyl phthalate (DINP) which is known to the State of California to cause Carcinogen and Reproductive harm. For more information go to www.p65warnings.ca.gov
RoHS Compliant Yes
Discount Schedule T
Return Indicator Yes
Depth 1.30 inch
Height 3.70 inch
Width 4.33 inch
Weight 0.79 pound
Characteristics
Range Of Product Preventa Safety detection
Product Or Component Type Safety switch
Component Name XCSTE
Design Rectangular
Material Plastic
Head Type Key operated turret head
Contacts Type And Composition 2 NC
Contact Operation Slow-break, simultaneous
Solenoid Contacts Type Compo 1 NC slow-break)
Cable Entry 1 entry tapped Pg 11
Electromagnet Interlocking Locking on de-energisation and unlocking on energisation of solenoid
[Us]&Nbsp;Solenoid&Nbsp;Rated&Nbsp;Supply Voltage 24 V - 20...10 %
Cable Outer Diameter 0.28…0.39 in (7…10 mm)
Electrical Connection Terminal 1 x 0.5...2 x 1.5 mm² with or without cable end
Number Of Poles 2
Locking Options Description With interlocking, locking by solenoid
Insulation Double insulated
Positive Opening With NC contact
Supply Voltage Type AC/DC
Supply Frequency 50/60 Hz
Load Factor 1
Power Consumption In Va 10 VA
Mechanical Durability 1000000 cycles
Positive Opening Min Force 15 N
Minimum Actuation Speed 0.03 ft/s (0.01 m/s)
Maximum Actuation Speed 1.64 ft/s (0.5 m/s)
Ie Rated Operational Current 0.55 A 125 V, DC-13, Q300 EN/IEC 60947-5-1 0.27 A 250 V, DC-13, Q300 EN/IEC 60947-5-1 3 A 120 V, AC-15, B300 EN/IEC 60947-5-1 1.5 A 240 V, AC-15, B300 EN/IEC 60947-5-1
Ithe Cnvtl Enclosed Therm Crrt 6 A
Ui Rated Insulation Voltage 300 VUL 508 500 VEN/IEC 60947-1 300 VCSA C22.2 No 14
Uimp Rated Imp Wstd Voltage 6 kV EN/IEC 60947-5-1
Short-Circuit Protection 10 A cartridge fuse gG (gl)
Actutr Forcible Withdrawal Rtc 500 N
Operating Rate 10 cyc/mn for maximum durability
Safety Level Can reach category 4 with the appropriate monitoring system and correctly wired EN/ISO 13849-1 Can reach PL = e with the appropriate monitoring system and correctly wired EN/ISO 13849-1 Can reach SIL 3 with the appropriate monitoring system and correctly wired EN/IEC 61508
Safety Reliability Data B10d = 5000000 value given for a life time of 20 years limited by mechanical or contact wear
Body Material PA (polyamide)
Head Material PA (polyamide)
Depth 1.30 in (33 mm)
Height 3.70 in (94 mm)
Width 4.33 in (110 mm)
Product Weight 0.79 lb(US) (0.36 kg)
Standards CSA C22.2 No 14 EN/IEC 60947-5-1 EN/ISO 12100 EN 1088/ISO 14119 EN/IEC 60204-1 UL 508
Product Certifications UL CSA
Protective Treatment TC
Ambient Air Temp For Op -13…140 °F (-25…60 °C)
Ambient Air Temp For Storage -40…158 °F (-40…70 °C)
Vibration Resistance 5 gn 10…500 Hz)IEC 60068-2-6
Shock Resistance 10 gn 11 ms IEC 60068-2-27
Electrical Shock Protect Class Class II EN/IEC 61140
IP Degree Of Protection IP67 EN/IEC 60529 and EN/IEC 60947-5-1
Documents
Royal Wholesale Electric

5.0

Powered by

Based on 2 User Reviews