This XCSTE Key Operated Safety Switch for guard doors with locking by solenoid has an adjustable turret head and a red coated polyamide body with a Pg 11 cable gland entry, allowing for flexible installation. It has 1 normally open and 1 normally closed break-before-make (slow break) main contacts actuated by key, contact states given when the key is inserted. And it has 1 normally closed auxiliary contacts actuated by the solenoid, contact states given when the solenoid is not powered. Its B10D reliability data is 5 000 000. Its IP67 degree of protection makes it ideal for heavy duty use in harsh conditions. It also complies with EN/ISO 14119, EN/IEC 60204-1, EN/IEC 60947-5-1, UL 508, CSA C22.2 No 14 standards. When associated and correctly connected to an appropriate safety control unit, it conforms to Category 4, performance level PL e, SIL 3 as described in EN/ISO 13849-1, EN/IEC 61508.
Brand: Telemecanique
Add to Quote CataloguePart Number | XCSTE5311 |
---|---|
Country of Origin | FR |
UPC | 785901651420 |
UPC11 | 78590165142 |
EAN | 3389110825077 |
Availability | N |
Lead Time | 33 |
UNSPSC | 39122213 |
ECCN | EAR99 |
HTs Code | 8536509055 |
Prop 65 | This product can expose you to chemicals including: Di-isodecyl phthalate (DIDP) and Diisononyl phthalate (DINP) which is known to the State of California to cause Carcinogen and Reproductive harm. For more information go to www.p65warnings.ca.gov |
RoHS Compliant | Yes |
Discount Schedule | T |
Return Indicator | Yes |
Depth | 1.30 inch |
Height | 3.70 inch |
Width | 4.33 inch |
Weight | 0.79 pound |
Range Of Product | Preventa Safety detection |
---|---|
Product Or Component Type | Safety switch |
Component Name | XCSTE |
Design | Rectangular |
Material | Plastic |
Head Type | Key operated turret head |
Contacts Type And Composition | 1 NC + 1 NO |
Contact Operation | Slow-break, break before make |
Solenoid Contacts Type Compo | 1 NC slow-break) |
Cable Entry | 1 entry tapped Pg 11 |
Electromagnet Interlocking | Locking on de-energisation and unlocking on energisation of solenoid |
[Us]&Nbsp;Solenoid&Nbsp;Rated&Nbsp;Supply Voltage | 24 V - 20...10 % |
Cable Outer Diameter | 0.28…0.39 in (7…10 mm) |
Electrical Connection | Terminal 1 x 0.5...2 x 1.5 mm² with or without cable end |
Number Of Poles | 2 |
Locking Options Description | With interlocking, locking by solenoid |
Insulation | Double insulated |
Positive Opening | With NC contact |
Supply Voltage Type | AC/DC |
Supply Frequency | 50/60 Hz |
Load Factor | 1 |
Power Consumption In Va | 10 VA |
Mechanical Durability | 1000000 cycles |
Positive Opening Min Force | 15 N |
Minimum Actuation Speed | 0.03 ft/s (0.01 m/s) |
Maximum Actuation Speed | 1.64 ft/s (0.5 m/s) |
Ie Rated Operational Current | 0.55 A 125 V, DC-13, Q300 EN/IEC 60947-5-1 0.27 A 250 V, DC-13, Q300 EN/IEC 60947-5-1 3 A 120 V, AC-15, B300 EN/IEC 60947-5-1 1.5 A 240 V, AC-15, B300 EN/IEC 60947-5-1 |
Ithe Cnvtl Enclosed Therm Crrt | 6 A |
Ui Rated Insulation Voltage | 300 VUL 508 500 VEN/IEC 60947-1 300 VCSA C22.2 No 14 |
Uimp Rated Imp Wstd Voltage | 6 kV EN/IEC 60947-5-1 |
Short-Circuit Protection | 10 A cartridge fuse gG (gl) |
Actutr Forcible Withdrawal Rtc | 500 N |
Operating Rate | 10 cyc/mn for maximum durability |
Safety Level | Can reach category 4 with the appropriate monitoring system and correctly wired EN/ISO 13849-1 Can reach PL = e with the appropriate monitoring system and correctly wired EN/ISO 13849-1 Can reach SIL 3 with the appropriate monitoring system and correctly wired EN/IEC 61508 |
Safety Reliability Data | B10d = 5000000 value given for a life time of 20 years limited by mechanical or contact wear |
Body Material | PA (polyamide) |
Head Material | PA (polyamide) |
Depth | 1.30 in (33 mm) |
Height | 3.70 in (94 mm) |
Width | 4.33 in (110 mm) |
Product Weight | 0.79 lb(US) (0.36 kg) |
Standards | EN/IEC 60204-1 CSA C22.2 No 14 EN/IEC 60947-5-1 UL 508 EN 1088/ISO 14119 EN/ISO 12100 |
Product Certifications | CSA UL |
Protective Treatment | TC |
Ambient Air Temp For Op | -13…140 °F (-25…60 °C) |
Ambient Air Temp For Storage | -40…158 °F (-40…70 °C) |
Vibration Resistance | 5 gn 10…500 Hz)IEC 60068-2-6 |
Shock Resistance | 10 gn 11 ms IEC 60068-2-27 |
Electrical Shock Protect Class | Class II EN/IEC 61140 |
IP Degree Of Protection | IP67 EN/IEC 60529 and EN/IEC 60947-5-1 |