Multi 9 – C60CTRL – MCB – 1P – 2 A – Z Curve – 240 V – 100 kA
M9C02302
Multi 9 – C60CTRL – MCB – 1P – 2 A – Z Curve – 240 V – 100 kA

This Multi9 C60CTRL is a low voltage miniature circuit breaker (MCB). It is a 1P circuit breaker with 1 protected pole, 2A rated current and Z tripping curve. The rated short circuit breaking capacity goes up to 100kA at 240VAC conforming to EN/IEC 60947-2 standard. This product complies with both industrial standard EN/IEC 60898-1 and residential standard EN/IEC 60947-2. It has been designed to offer enhanced protection by preventing, protecting people and equipment from electrical threats. This product protects from short circuit, earth leakage and overload. Its fast closing mechanism and good overvoltage withstand capacity improve its service life. This product is dedicated for original equipment manufacturers (OEM) and control panel builders. It has an electrical endurance going up to 10000 cycles and a mechanical endurance going up to 20000 cycles. The Ue operational voltage is 240VAC. The Ui rated insulation voltage is 500VAC. The Uimp rated impulse withstand voltage is 6kV. The operating frequency is 50Hz or 60Hz. The product can be clipped on a DIN rail. Its width is 2 pitches of 9mm. Pollution degree is 3. The product colour is light grey (RAL7035). The dimensions are (W) 18mm x (H) 81mm x (D) 72mm. The weight is 0.12kg. It has an IP20 degree of protection (as per IEC/EN 60529) on its terminals. The operating temperature is -30°C to 70°C. The storage temperature is -40°C to 80°C.

Add to Quote Catalogue
Specifications
Part Number M9C02302
UPC 606480631450
UPC11 60648063145
EAN 3606480631450
UNSPSC 39121603
Depth 2.83 inch
Height 3.19 inch
Width 0.71 inch
Weight 0.26 pound
Characteristics
Range Multi 9
Product Name Multi 9 C60
Product Or Component Type Miniature circuit-breaker
Device Short Name C60CTRL
Device Application Distribution
Poles Description 1P
Number Of Protected Poles 1
In Rated Current 2 A
Network Type AC DC
Trip Unit Technology Thermal-magnetic
Curve Code Z
Breaking Capacity 100 kA Icu 240 V AC 50/60 Hz EN/IEC 60947-2 25 kA Icu 60 V DC EN/IEC 60947-2
Utilisation Category Category A EN/IEC 60947-2
Suitability For ISOlation Yes EN/IEC 60947-2
Standards EN/IEC 60947-2
Product Certifications CE
Network Frequency 50/60 Hz
Ue Rated Operational Voltage 240 V AC 50/60 Hz between phase and neutral 60 V DC
Magnetic Tripping Limit 3 x In +/- 20 % AC 4.2 x In +/- 20 % DC
Ics Rated Service Breaking Cap 50 kA 50 % EN/IEC 60947-2 - 240 V AC 50/60 Hz 25 kA 100 % EN/IEC 60947-2 - 60 V DC
Ui Rated Insulation Voltage 500 V AC 50/60 Hz EN/IEC 60947-2
Uimp Rated Imp Wstd Voltage 6 kVEN/IEC 60947-2
Contact Position Indicator Yes
Control Type Toggle
Local Signalling ON/OFF indication
Mounting Mode Clip-on
Mounting Support DIN rail
9 mm Pitches 2
Height 3.19 in (81 mm)
Width 0.71 in (18 mm)
Depth 2.83 in (72 mm)
Product Weight 0.26 lb(US) (0.12 kg)
Colour Gray
Mechanical Durability 20000 cycles
Electrical Durability 10000 cycles
Provision For Padlocking Padlockable
Connections - Terminals Tunnel type terminal top or bottom) 0.00…0.04 in² (1…25 mm²) - rigid Tunnel type terminal top or bottom) 0.00…0.04 in² (1…25 mm²) - flexible Tunnel type terminal top or bottom) 0.00…0.04 in² (1…25 mm²) - flexible with ferrule
Wire Stripping Length 0.55 in (14 mm) top or bottom
Tightening Torque 17.70 lbf.in (2 N.m) top or bottom
Earth-Leakage Protection Separate block
IP Degree Of Protection IP20IEC 60529 IP40 modular enclosure)IEC 60529
Pollution Degree 3 EN/IEC 60947-2
Tropicalisation 2 IEC 60068-1
Relative Humidity 95 % 131 °F (55 °C)
Ambient Air Temp For Op -22…158 °F (-30…70 °C)
Ambient Air Temp For Storage -40…176 °F (-40…80 °C)
GTIN 03606480631450