TeSys GV manual self protected combination starters meet the requirements of UL 508 Type F, see UL File E164871. Manual motor starter consists of a GV2P02 motor starter protector and a LC1D09B7 IEC contactor assembled together into one device. The GV2P02 high performance manual starter with a rotary handle offers a high withstand rating and visible trip indication. The GV2P02 provides trip on overload, short circuit, undervoltage, or shunt trip. It has a 0.16 to 0.25 A thermal setting. The LC1D09B7 IEC contactor is rated 9 amperes and has a 24 VAC 50/60 Hz coil.
Add to Quote CataloguePart Number | GV2P02KD09B7 |
---|---|
Availability | N |
Lead Time | 3 |
UNSPSC | 39121521 |
Prop 65 | This product can expose you to chemicals including: Antimony oxide & Antimony trioxide which is known to the State of California to cause Carcinogen harm. For more information go to www.p65warnings.ca.gov |
RoHS Compliant | Yes |
Discount Schedule | I11 |
Return Indicator | No |
Depth | 3.82 inch |
Height | 3.50 inch |
Width | 1.77 inch |
Weight | 0.71 pound |
Range | TeSys |
---|---|
Product Or Component Type | Motor starter |
Contactor Application | Resistive load Motor control |
Utilisation Category | AC-4 AC-1 AC-3 |
Poles Description | 3P |
Power Pole Contact Composition | 3 NO |
Ue Rated Operational Voltage | Power circuit <= 690 V AC 25...400 Hz Power circuit <= 300 V DC |
Ie Rated Operational Current | 9 A 140 °F (60 °C)) <= 440 V AC AC-3 power circuit 25 A 140 °F (60 °C)) <= 440 V AC AC-1 power circuit |
Motor Power kW | 2.2 kW 220...230 V AC 50/60 Hz AC-3) 4 kW 380...400 V AC 50/60 Hz AC-3) 4 kW 415...440 V AC 50/60 Hz AC-3) 5.5 kW 500 V AC 50/60 Hz AC-3) 5.5 kW 660...690 V AC 50/60 Hz AC-3) 2.2 kW 400 V AC 50/60 Hz AC-4) |
Motor Power Hp (Ul / Csa) | 1 hp 230/240 V AC 50/60 Hz 1 phase 2 hp 200/208 V AC 50/60 Hz 3 phase 2 hp 230/240 V AC 50/60 Hz 3 phase 5 hp 460/480 V AC 50/60 Hz 3 phase 7.5 hp 575/600 V AC 50/60 Hz 3 phase 0.33 hp 115 V AC 50/60 Hz 1 phase |
Control Circuit Type | AC 50/60 Hz |
Uc Control Circuit Voltage | 24 V AC 50/60 Hz |
Auxiliary Contact Composition | 1 NO + 1 NC |
Uimp Rated Imp Wstd Voltage | 6 kV IEC 60947 |
Overvoltage Category | III |
Ith Cnvtl Free Air Therm Crrt | 25 A 140 °F (60 °C) power circuit 10 A 140 °F (60 °C) signalling circuit |
Irms Rated Making Capacity | 250 A 440 V power circuit IEC 60947 140 A AC signalling circuit IEC 60947-5-1 250 A DC signalling circuit IEC 60947-5-1 |
Rated Breaking Capacity | 250 A 440 V power circuit IEC 60947 |
Icw Rated Short-Time Wstd Crrt | 105 A 104 °F (40 °C) - 10 s power circuit 210 A 104 °F (40 °C) - 1 s power circuit 30 A 104 °F (40 °C) - 10 min power circuit 61 A 104 °F (40 °C) - 1 min power circuit 100 A - 1 s signalling circuit 120 A - 500 ms signalling circuit 140 A - 100 ms signalling circuit |
Associated Fuse Rating | 10 A gG signalling circuit IEC 60947-5-1 25 A gG <= 690 V type 1 power circuit 20 A gG <= 690 V type 2 power circuit |
Average Impedance | 2.5 mOhm - Ith 25 A 50 Hz power circuit |
Ui Rated Insulation Voltage | Power circuit 690 V IEC 60947-4-1 Power circuit 600 V CSA Power circuit 600 V UL Signalling circuit 690 V IEC 60947-1 Signalling circuit 600 V CSA Signalling circuit 600 V UL |
Electrical Durability | 0.6 Mcycles 25 A AC-1 <= 440 V 2 Mcycles 9 A AC-3 <= 440 V |
Power Dissipation Per Pole | 1.56 W AC-1 0.2 W AC-3 |
Safety Cover | With |
Mounting Support | Rail Plate |
Standards | CSA C22.2 No 14 EN 60947-4-1 EN 60947-5-1 IEC 60947-4-1 IEC 60947-5-1 UL 508 |
Product Certifications | GL CSA GOST RINA LROS (Lloyds register of shipping) UL DNV BV CCC |
Connections - Terminals | Power circuit screw clamp terminals 1 0.00…0.01 in² (1…4 mm²)flexible without cable end Power circuit screw clamp terminals 2 0.00…0.01 in² (1…4 mm²)flexible without cable end Power circuit screw clamp terminals 1 0.00…0.01 in² (1…4 mm²)flexible with cable end Power circuit screw clamp terminals 2 0.00…0.00 in² (1…2.5 mm²)flexible with cable end Power circuit screw clamp terminals 1 0.00…0.01 in² (1…4 mm²)solid without cable end Power circuit screw clamp terminals 2 0.00…0.01 in² (1…4 mm²)solid without cable end Control circuit screw clamp terminals 1 0.00…0.01 in² (1…4 mm²)flexible without cable end Control circuit screw clamp terminals 2 0.00…0.01 in² (1…4 mm²)flexible without cable end Control circuit screw clamp terminals 1 0.00…0.01 in² (1…4 mm²)flexible with cable end Control circuit screw clamp terminals 2 0.00…0.00 in² (1…2.5 mm²)flexible with cable end Control circuit screw clamp terminals 1 0.00…0.01 in² (1…4 mm²)solid without cable end Control circuit screw clamp terminals 2 0.00…0.01 in² (1…4 mm²)solid without cable end |
Tightening Torque | Power circuit 15.05 lbf.in (1.7 N.m) screw clamp terminals flat Ø 6 mm Power circuit 15.05 lbf.in (1.7 N.m) screw clamp terminals Philips No 2 Control circuit 15.05 lbf.in (1.7 N.m) screw clamp terminals flat Ø 6 mm Control circuit 15.05 lbf.in (1.7 N.m) screw clamp terminals Philips No 2 |
Operating Time | 12...22 ms closing 4...19 ms opening |
Safety Reliability Level | B10d = 1369863 cycles contactor with nominal load EN/ISO 13849-1 B10d = 20000000 cycles contactor with mechanical load EN/ISO 13849-1 |
Mechanical Durability | 15 Mcycles |
Operating Rate | 3600 cyc/h 140 °F (60 °C) |
Trip Unit Rating | 0.16…0.25 A |
Trip Unit Technology | Thermal-magnetic |
Suitability For ISOlation | Yes IEC 60947-1 |
Phase Failure Sensitivity | Yes IEC 60947-4-1 |
Coil Technology | Without built-in suppressor module |
Ctrl Circuit Voltage Limits | Drop-out 0.3...0.6 Uc AC 50/60 Hz 140 °F (60 °C)) Operational 0.8...1.1 Uc AC 50 Hz 140 °F (60 °C)) Operational 0.85...1.1 Uc AC 60 Hz 140 °F (60 °C)) |
Inrush Power In VA | 70 VA 60 Hz 0.75 68 °F (20 °C)) 70 VA 50 Hz 0.75 68 °F (20 °C)) |
Hold-In Power Consumption Va | 7.5 VA 60 Hz 0.3 68 °F (20 °C)) 7 VA 50 Hz 0.3 68 °F (20 °C)) |
Heat Dissipation | 2…3 W 50/60 Hz |
Auxiliary Contacts Type | Mechanically linked 1 NO + 1 NC IEC 60947-5-1 Mirror contact 1 NC IEC 60947-4-1 |
Signalling Circuit Frequency | 25...400 Hz |
Minimum Switching Current | 5 mA signalling circuit |
Minimum Switching Voltage | 17 V signalling circuit |
Non-Overlap Time | 1.5 ms on de-energisation between NC and NO contact 1.5 ms on energisation between NC and NO contact |
Insulation Resistance | > 10 MOhm signalling circuit |
Contact Compatibility | M2 |