Part Number | LTMR27CBD |
---|---|
Country of Origin | CN |
UPC | 785901502296 |
UPC11 | 78590150229 |
EAN | 3389119404709 |
Availability | S |
Lead Time | 40 |
UNSPSC | 39122214 |
ECCN | EAR99 |
HTs Code | 8536509065 |
RoHS Compliant | Yes |
Discount Schedule | I12 |
Return Indicator | No |
Depth | 4.82 inch |
Height | 2.40 inch |
Width | 3.58 inch |
Weight | 1.17 pound |
Range | TeSys |
---|---|
Product Name | TeSys T |
Device Short Name | LTMR |
Product Or Component Type | Motor controller |
Device Application | Equipment monitoring and control |
Measurement Current | 1.35…27 A |
[Us] Rated Supply Voltage | 24 V DC |
Current Consumption | 56...127 mA |
Supply Voltage Limits | 20.4…26.24 V DC |
Communication Port Protocol | CANopen |
Bus Type | CANopen ISO 1198 1...127 10...1000 kbit/s, SUB-D 9 4 twisted shielded pairs cable CANopen ISO 1198 1...127 10...1000 kbit/s, terminal block 4 twisted shielded pairs cable |
Ui Rated Insulation Voltage | 690 V EN/IEC 60947-1 690 V CSA C22.2 No 14 690 V UL 508 |
Uimp Rated Imp Wstd Voltage | 6 kV current or voltage measurement circuit EN/IEC 60947-4-1 0.8 kV communication circuit EN/IEC 60947-4-1 0.8 kV supply, inputs and outputs EN/IEC 60947-4-1 |
Short-Circuit Withstand | 100 kA EN/IEC 60947-4-1 |
Associated Fuse Rating | 4 A gG output 0.5 A gG control circuit |
Protection Type | Overload (long time) Thermal protection Load fluctuation Locked rotor Overload Thermal overload protection Power factor variation Phase unbalance Reverse polarity protection Earth-leakage protection Phase failure |
Ntw And Machine Diagnosis Type | Phase fault and earth fault trip counters Trip context information Waiting time after overload tripping Fault recording Remaining operating time before overload tripping Starting current and time Motor control command recording Event recording Running hours counter/operating time Trip history information |
Logic Input Number | 6 |
Input Current | 7 mA |
Current State 0 Guaranteed | Logic input < 5 V <= 15 mA 5 ms |
Current State 1 Guaranteed | Logic input < 15 V 2...15 mA 15 ms |
Maximum Output Switching Frequency | 2 Hz |
Load Current | 5 A 250 V AC logic output 5 A 30 V DC logic output |
Permissible Power | 480 VA AC-15), Ie = 2 A, 500000 cycles output) 30 W DC-13), Ie = 1.25 A, 500000 cycles output) |
Operating Rate | 1800 cyc/h |
Contacts Type And Composition | 1 NO + 1 NC fault signal 3 NO |
Metering Type | Temperature Imbalance current Phase current I1, I2, I3 RMS Earth-fault current Average current Iavg |
Measurement Accuracy | 5...15 % earth fault current internal measurement 1 % voltage 100...830 V) 3 % power factor 5 % earth fault current external measurement +/- 30 min/year internal clock 0,02 temperature 1 % current 5 % active and reactive power |
Overvoltage Category | III |
Connection Pitch | 0.20 in (5.08 mm) |
Connections - Terminals | Control circuit connector 1 0.00…0.00 in² (0.25…2.5 mm²) AWG 24...AWG 14)flexible with cable end Control circuit connector 1 0.00…0.00 in² (0.2…2.5 mm²) AWG 24...AWG 14)flexible without cable end Control circuit connector 1 0.00…0.00 in² (0.25…2.5 mm²) AWG 24...AWG 14)flexible without cable end Control circuit connector 1 0.00…0.00 in² (0.2…2.5 mm²) AWG 24...AWG 14)solid without cable end Control circuit connector 2 0.00…0.00 in² (0.2…1 mm²) AWG 24...AWG 14)flexible with cable end Control circuit connector 2 0.00…0.00 in² (0.2…1.5 mm²) AWG 24...AWG 14)flexible without cable end Control circuit connector 2 0.00…0.00 in² (0.5…1.5 mm²) AWG 24...AWG 14)flexible without cable end Control circuit connector 2 0.00…0.00 in² (0.2…1 mm²) AWG 24...AWG 14)solid without cable end |
Tightening Torque | Control circuit 4.43…5.31 lbf.in (0.5…0.6 N.m) flat 0.12 in (3 mm) |
Pollution Degree | 3 |
Electromagnetic Compatibility | Electrostatic discharge, 3 8 kV air, 6 kV contact)EN/IEC 61000-4-2) Radiated RF fields, 3 10 V/m)EN/IEC 61000-4-3) Fast transients immunity test, level 3 2 kV)EN/IEC 61000-4-4) Fast transients immunity test, level 4 4 kV)EN/IEC 61000-4-4) Voltage dips and interruptions immunity test 70 %, 500 ms)EN/IEC 61000-4-11) Conducted RF disturbances 10 V)EN/IEC 61000-4-6) Surges 0.5 kV)EN/IEC 61000-4-5) Surges 1 kV)EN/IEC 61000-4-5) Surges 1 kV)EN/IEC 61000-4-5) Surges 1 kV)EN/IEC 61000-4-5) Surges 2 kV)EN/IEC 61000-4-5) Surges 2 kV)EN/IEC 61000-4-5) Surges 4 kV)EN/IEC 61000-4-5) |
Width | 3.58 in (91 mm) |
Height | 2.40 in (61 mm) |
Depth | 4.82 in (122.5 mm) |
Product Weight | 1.17 lb(US) (0.53 kg) |
Web Services | Web server |
Compatibility Code | LTMR |
Standards | CSA C22.2 No 14 IEC 60947-4-1 EN 60947-4-1 IACS E10 UL 508 |
Product Certifications | CSA DNV RINA KERI NOM BV CCC EAC ATEX ABS LROS (Lloyds register of shipping) C-tick GL UL RMRoS |
Protective Treatment | 12 x 24 hour cycles EN/IEC 60068-2-30 48 h EN/IEC 60070-2-11 TH EN/IEC 60068 |
Fire Resistance | 1202 °F (650 °C) EN/IEC 60695-2-12 1760 °F (960 °C) UL 94 |
Ambient Air Temp For Op | -4…140 °F (-20…60 °C) |
Ambient Air Temp For Storage | -40…176 °F (-40…80 °C) |
Operating Altitude | <= 6561.68 ft (2000 m) without derating |
Mechanical Robustness | Vibrations mounted on symmetrical rail1 Gn, 5...300 Hz EN/IEC 60068-2-6 Vibrations plate mounted4 Gn, 5...300 Hz EN/IEC 60068-2-6 Shocks half sine wave acceleration15 Gn for 11 ms EN/IEC 60068-2-27 |
IP Degree Of Protection | IP20 |
Category | 22338 - SOLID STATE OVERLOAD RELAYS |