Part Number | LTMR100PBD |
---|---|
Country of Origin | CN |
UPC | 785901502371 |
UPC11 | 78590150237 |
EAN | 3389119404846 |
Availability | S |
Lead Time | 36 |
UNSPSC | 39122214 |
ECCN | EAR99 |
HTs Code | 8537109160 |
RoHS Compliant | Yes |
Discount Schedule | I12 |
Return Indicator | No |
Depth | 4.82 inch |
Height | 2.40 inch |
Width | 3.58 inch |
Weight | 1.17 pound |
Range | TeSys |
---|---|
Product Name | TeSys T |
Device Short Name | LTMR |
Product Or Component Type | Motor controller |
Device Application | Equipment monitoring and control |
Measurement Current | 5…100 A |
[Us] Rated Supply Voltage | 24 V DC |
Current Consumption | 56...127 mA |
Supply Voltage Limits | 20.4…26.24 V DC |
Communication Port Protocol | Profibus DP |
Bus Type | Profibus DP polarised 2-wire RS485 1...125 9.6 kbit/s...12 Mbit/s, SUB-D 9 2 shielded twisted pairs, type A Profibus DP polarised 2-wire RS485 1...125 9.6 kbit/s...12 Mbit/s, terminal block 2 shielded twisted pairs, type A |
Ui Rated Insulation Voltage | 690 V EN/IEC 60947-1 690 V CSA C22.2 No 14 690 V UL 508 |
Uimp Rated Imp Wstd Voltage | 6 kV current or voltage measurement circuit EN/IEC 60947-4-1 0.8 kV communication circuit EN/IEC 60947-4-1 0.8 kV supply, inputs and outputs EN/IEC 60947-4-1 |
Short-Circuit Withstand | 100 kA EN/IEC 60947-4-1 |
Associated Fuse Rating | 4 A gG output 0.5 A gG control circuit |
Protection Type | Load fluctuation Reverse polarity protection Locked rotor Thermal protection Overload (long time) Overload Power factor variation Earth-leakage protection Thermal overload protection Phase unbalance Phase failure |
Ntw And Machine Diagnosis Type | Trip context information Event recording Waiting time after overload tripping Running hours counter/operating time Remaining operating time before overload tripping Fault recording Motor control command recording Trip history information Phase fault and earth fault trip counters Starting current and time |
Logic Input Number | 6 |
Input Current | 7 mA |
Current State 0 Guaranteed | Logic input < 5 V <= 15 mA 5 ms |
Current State 1 Guaranteed | Logic input < 15 V 2...15 mA 15 ms |
Maximum Output Switching Frequency | 2 Hz |
Load Current | 5 A 250 V AC logic output 5 A 30 V DC logic output |
Permissible Power | 480 VA AC-15), Ie = 2 A, 500000 cycles output) 30 W DC-13), Ie = 1.25 A, 500000 cycles output) |
Operating Rate | 1800 cyc/h |
Contacts Type And Composition | 1 NO + 1 NC fault signal 3 NO |
Metering Type | Imbalance current Temperature Average current Iavg Phase current I1, I2, I3 RMS Earth-fault current |
Measurement Accuracy | 5...15 % earth fault current internal measurement 1 % voltage 100...830 V) 3 % power factor 5 % earth fault current external measurement +/- 30 min/year internal clock 0,02 temperature 5 % active and reactive power 0,02 current |
Overvoltage Category | III |
Connection Pitch | 0.20 in (5.08 mm) |
Connections - Terminals | Control circuit connector 1 0.00…0.00 in² (0.25…2.5 mm²) AWG 24...AWG 14)flexible with cable end Control circuit connector 1 0.00…0.00 in² (0.2…2.5 mm²) AWG 24...AWG 14)flexible without cable end Control circuit connector 1 0.00…0.00 in² (0.25…2.5 mm²) AWG 24...AWG 14)flexible without cable end Control circuit connector 1 0.00…0.00 in² (0.2…2.5 mm²) AWG 24...AWG 14)solid without cable end Control circuit connector 2 0.00…0.00 in² (0.2…1 mm²) AWG 24...AWG 14)flexible with cable end Control circuit connector 2 0.00…0.00 in² (0.2…1.5 mm²) AWG 24...AWG 14)flexible without cable end Control circuit connector 2 0.00…0.00 in² (0.5…1.5 mm²) AWG 24...AWG 14)flexible without cable end Control circuit connector 2 0.00…0.00 in² (0.2…1 mm²) AWG 24...AWG 14)solid without cable end |
Tightening Torque | Control circuit 4.43…5.31 lbf.in (0.5…0.6 N.m) flat 0.12 in (3 mm) |
Pollution Degree | 3 |
Electromagnetic Compatibility | Electrostatic discharge, 3 8 kV air, 6 kV contact)EN/IEC 61000-4-2) Radiated RF fields, 3 10 V/m)EN/IEC 61000-4-3) Fast transients immunity test, level 3 2 kV)EN/IEC 61000-4-4) Fast transients immunity test, level 4 4 kV)EN/IEC 61000-4-4) Voltage dips and interruptions immunity test 70 %, 500 ms)EN/IEC 61000-4-11) Conducted RF disturbances 10 V)EN/IEC 61000-4-6) Surges 0.5 kV)EN/IEC 61000-4-5) Surges 1 kV)EN/IEC 61000-4-5) Surges 1 kV)EN/IEC 61000-4-5) Surges 1 kV)EN/IEC 61000-4-5) Surges 2 kV)EN/IEC 61000-4-5) Surges 2 kV)EN/IEC 61000-4-5) Surges 4 kV)EN/IEC 61000-4-5) |
Width | 3.58 in (91 mm) |
Height | 2.40 in (61 mm) |
Depth | 4.82 in (122.5 mm) |
Product Weight | 1.17 lb(US) (0.53 kg) |
Web Services | Web server |
Compatibility Code | LTMR |
Standards | CSA C22.2 No 14 EN 60947-4-1 IEC 60947-4-1 IACS E10 UL 508 |
Product Certifications | CSA C-tick DNV RMRoS ATEX EAC RINA CCC KERI GL NOM UL LROS (Lloyds register of shipping) ABS BV |
Protective Treatment | 12 x 24 hour cycles EN/IEC 60068-2-30 48 h EN/IEC 60070-2-11 TH EN/IEC 60068 |
Fire Resistance | 1202 °F (650 °C) EN/IEC 60695-2-12 1760 °F (960 °C) UL 94 |
Ambient Air Temp For Op | -4…140 °F (-20…60 °C) |
Ambient Air Temp For Storage | -40…176 °F (-40…80 °C) |
Operating Altitude | <= 6561.68 ft (2000 m) without derating |
Mechanical Robustness | Vibrations mounted on symmetrical rail1 Gn, 5...300 Hz EN/IEC 60068-2-6 Vibrations plate mounted4 Gn, 5...300 Hz EN/IEC 60068-2-6 Shocks half sine wave acceleration15 Gn for 11 ms EN/IEC 60068-2-27 |
IP Degree Of Protection | IP20 |
Category | 22338 - SOLID STATE OVERLOAD RELAYS |