Motor circuit breaker, TeSys GV4, 3P, 50A, Icu 50kA, thermal magnetic, multifunction, UL489
GV4PB50N
Motor circuit breaker, TeSys GV4, 3P, 50A, Icu 50kA, thermal magnetic, multifunction, UL489

TeSys GV motor circuit breaker, 3 poles (3P), 50A/690V, for protection of 3-phase motors 11-22kW@400V. Multifunction circuit breaker UL489 compliant, it provides thermal magnetic protection and advanced motor protection, breaking capacity Icu 50kA@400V, start-stop control by toggle, connection by Everlink BTR screw terminals. Thermal protection adjustable by dials with a setting current Ir in range 20-50A, a selectable tripping class 10 or 20, rated tripping current 125%, magnetic protection at 17 In. Advanced protections are adjustable with a smartphone using wireless NFC and include short time delay protection Isd with a setting range 5-13 Ir, phase unbalance and loss protection, ground fault protection, locked rotor (jam), long start. It makes internal locations available for additional auxiliary contact blocks (OF, SD), and voltage trip units (MN, MX). It can be equiped externally with 1 or 2 auxiliary SDx modules in order to have alarming and fault differentiation. Multi standards certified (IEC, UL 489, CSA C22.2 N°5), Green Premium compliant (RoHS/REACh).

Add to Quote Catalogue
Specifications
Part Number GV4PB50N
Country of Origin US
UPC 606489868604
UPC11 60648986860
EAN 3606489868604
Availability N
Lead Time 9
UNSPSC 39121601
ECCN EAR99
HTs Code 8536200020
RoHS Compliant Yes
Discount Schedule I11
Return Indicator Yes
Depth 4.57 inch
Height 6.73 inch
Width 3.19 inch
Weight 3.20 pound
Characteristics
Range TeSys
Product Name TeSys GV4
Device Short Name GV4PB
Product Or Component Type Multifunction circuit breaker
Device Application Motor protection
Protection Type Overload protection Short-circuit protection Short time short-circuit protection Ground fault protection Phase unbalance Phase loss Locked rotor Long start Jam
Utilisation Category Category A
Suitability For ISOlation Yes IEC 60947-1
Poles Description 3P
Ue Rated Operational Voltage 690 V AC 50/60 Hz IEC 60947-2 600Y/347 V AC 60 Hz UL 489
In Rated Current 50 A
Continuous Current Rating 100 %, minimum dimensions enclosure: 373 mm x 218 mm x 108 mm (H x W x D)
Trip Unit Technology Electronic Thermal-magnetic
Magnetic Tripping Current 850 A
Isd Short-Time Pick-Up Adj 5...13 x Ir adjustable with EcoStruxure Power
Thermal Protection Adj Range 20…50 A adjustable by rotary dial
Motor Tripping Class UL 489 UL 489 CSA C22.2 No 5 CSA C22.2 No 5
Phase Failure Sensitivity Yes IEC 60947-4-1
Breaking Capacity SCCR 65 kA 240 V AC 60 Hz UL 489 SCCR 35 kA 480Y/277 V AC 60 Hz UL 489 SCCR 18 kA 600Y/347 V AC 60 Hz UL 489 Icu 100 kA 220/240 V AC 50/60 Hz IEC 60947-2 Icu 50 kA 380/415 V AC 50/60 Hz IEC 60947-2 Icu 50 kA 440 V AC 50/60 Hz IEC 60947-2 Icu 25 kA 500 V AC 50/60 Hz IEC 60947-2 Icu 15 kA 525 V AC 50/60 Hz IEC 60947-2 Icu 8 kA 660/690 V AC 50/60 Hz IEC 60947-2
Ics Rated Ser Sc Brking Cap 100 % 220/240 V AC 50/60 Hz IEC 60947-2 100 % 380/415 V AC 50/60 Hz IEC 60947-2 100 % 440 V AC 50/60 Hz IEC 60947-2 100 % 500 V AC 50/60 Hz IEC 60947-2 100 % 525 V AC 50/60 Hz IEC 60947-2 25 % 660/690 V AC 50/60 Hz IEC 60947-2
Uimp Rated Imp Wstd Voltage 8 kV IEC 60947-2
Ui Rated Insulation Voltage 800 V IEC 60947-2
Mechanical Durability 40000 cycles
Electrical Durability 20000 cycles AC-3 440 V In/2 10000 cycles AC-3 440 V In
Control Type Toggle
Handle Padlocking With a lock accessory
Number Of Slots 1 alarm switch fault signalling contact, plug-in 1 voltage release electrical remote tripping, plug-in 1 auxiliary switch open/close contact, plug-in
Local Signalling Ready flashing LED green) Alarm (T° >95%) LED red) Presence of auxiliary contacts green indicator
Communication Port Protocol NFC
Standards EN/IEC 60947-1 EN/IEC 60947-2 EN/IEC 60947-4-1 UL 489 CSA C22.2 No 5
Product Certifications IEC UL CSA
Mounting Mode Clip-on By screws
Mounting Support Plate 35 mm symmetrical DIN rail 75 mm symmetrical DIN rail
Connections - Terminals Top 1 EverLink BTR screw connectors 0.00…0.11 in² (1.5…70 mm²), rigid Top 1 EverLink BTR screw connectors 0.00…0.08 in² (1.5…50 mm²), flexible Bottom 1 EverLink BTR screw connectors 0.00…0.15 in² (2.5…95 mm²), rigid Bottom 1 EverLink BTR screw connectors 0.00…0.11 in² (2.5…70 mm²), flexible
Connection Pitch 1.06 in (27 mm) with spreader)
Wire Stripping Length 0.79 in (20 mm)
Tightening Torque 79.66 lbf.in (9 N.m) 0.02…0.15 in² (16…95 mm²) 44.25 lbf.in (5 N.m) 0.00…0.02 in² (1.5…10 mm²)
Width 3.19 in (81 mm)
Height 6.73 in (171 mm)
Depth 4.57 in (116 mm)
Product Weight 3.20 lb(US) (1.45 kg)
Colour Gray RAL 7016)
Ambient Air Temp For Storage -58…185 °F (-50…85 °C)
Ambient Air Temp For Op -13…158 °F (-25…70 °C)
Operating Altitude 0...6561.68 ft (0...2000 m) without derating 2000...5000 m with derating
IP Degree Of Protection IP40 front face IEC 60529
IK Degree Of Protection IK07 IEC 62262
Pollution Degree 3 IEC 60947-1
Tropicalisation 2 IEC 68-2
Mechanical Robustness Vibrations +/- 1 mm 2...13.2 Hz IEC 60068-2-6 Vibrations 0.7 gn 13.2...100 Hz IEC 60068-2-6 Shocks 15 gn 11 ms IEC 60068-2-27