SD326RU25S2
Motion control stepper motor drive – SD326 – pulse/direction –
Specifications
Part Number SD326RU25S2
Country of Origin DE
UPC 389119224338
UPC11 38911922433
EAN 3389119224338
Availability N
Lead Time 28
UNSPSC 26111515
ECCN 3A225
HTs Code 8504404000
Prop 65 This product can expose you to chemicals including: Lead and lead compounds which is known to the State of California to cause Carcinogen & Reproductive harm. For more information go to www.p65warnings.ca.gov
RoHS Compliant Yes
Discount Schedule PC55
Return Indicator No
Depth 5.51 inch
Height 5.71 inch
Width 2.83 inch
Weight 2.43 pound
Characteristics
Range Of Product Lexium SD3
Product Or Component Type Motion stepper drive
Device Short Name SD326
Supply Voltage Limits 200…240 V 100…120 V
Format Of The Drive Block
Network Number Of Phases Single phase
Us Rated Supply Voltage 100...120 V - 15...10 % 200...230 V - 15...10 %
Supply Voltage Type AC/DC
Network Frequency Limits 50…60 Hz - 15...10 %)
Communication Interface Pulse/direction, Integrated
Function Available Rotation monitoring Holding brake monitoring
Motor Phase Current 2.5 A
Current Consumption <= 0.2 mA 24 V control voltage
Nominal Power 180 W 115 V 270 W 230 V
Short-Circuit Current 0.5 kA
Associated Fuse Rating 6 A 115 V 6 A 230 V
Overvoltage Category III
Inrush Current 60 A
Leakage Current 30 mA IEC 60990-3
Voltage State 0 Guaranteed <= 5 V 24 V optocoupler input signals <= 0.5 V 5 V optocoupler input signals
Voltage State 1 Guaranteed 15...30 V 24 V optocoupler input signals 2.5...5.25 V 5 V optocoupler input signals
Input Current 25 mA 5 V optocoupler input signals 7 mA 24 V optocoupler input signals
Input Frequency 200 kHz 24 V optocoupler input signals 200 kHz 5 V optocoupler input signals 400 kHz ENC_A/ENC_B signal input
Maximum Switching Voltage 30 V DC readiness signal output)
Maximum Switching Current 200 mA readiness signal output) 50 mA 24 V output signals)RM-FAULT_OUT 1.7 mA 24 V output signals)+BRAKE_OUT
Voltage Drop <1 V 50 mA load 24 V output signals <1 V 50 mA load ENC+5V_OUT signal output <1 V 50 mA load readiness signal output
Physical Interface RS422 - ENC_A/ENC_B signal input
Output Voltage <= 30 V 24 V output signals) 4.75...5.25 V ENC+5V_OUT signal output)
Input Voltage 24 V -15 %/+20 % 24 V control voltage
Residual Ripple <= 5 % 24 V control voltage)
Type Of Cooling Natural convection
Maximum Mechanical Speed 3000 rpm
Height 5.71 in (145 mm)
Width 2.83 in (72 mm)
Depth 5.51 in (140 mm)
Shock Resistance 15 gn 11 ms EN/IEC 60068-2-27
Product Weight 2.43 lb(US) (1.1 kg)
Electromagnetic Compatibility Electrostatic discharge level 3 EN/IEC 61000-4-2 Immunity to electrical transients level 4 EN/IEC 61000-4-4 Immunity to radiated radio-electrical interference level 3 EN/IEC 61000-4-3 Voltage/current impulse level 3 EN/IEC 61000-4-5
Standards EN/IEC 61800-5-1 EN/IEC 61800-3 EN/IEC 61800-3 environment 2 EN/IEC 61800-3 environment 1 EN/IEC 50178
Product Certifications UL CUL
Marking CE
Ambient Air Temp For Op 32…104 °F (0…40 °C) UL 32…122 °F (0…50 °C)
Ambient Air Temp For Storage -13…158 °F (-25…70 °C)
Pollution Degree Level 2
Relative Humidity 5…85 % without condensation
Operating Altitude <= 3280.84 ft (1000 m) without derating > 3280.84...< 6561.68 ft (> 1000...< 2000 m) without derating maximum ambient temperature 40°C, no protective film, lateral distance of > 50mm)
Vibration Resistance 1 gn 13…150 Hz)EN/IEC 60068-2-6 1.5 mm 3…13 Hz)EN/IEC 60068-2-6
IP Degree Of Protection IP20 On upper part IP40 without removal of protective film)